55 resultados para diffusion of information
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
The migration of radioactive and chemical contaminants in clay materials and argillaceous host rocks is characterised by diffusion and retention processes. Valuable information on such processes can be gained by combining diffusion studies at laboratory scale with field migration tests. In this work, the outcome of a multi-tracer in situ migration test performed in the Opalinus Clay formation in the Mont Terri underground rock laboratory (Switzerland) is presented. Thus, 1.16 x 10(5) Bq/L of HTO, 3.96 x 10(3) Bq/L of Sr-85, 6.29 x 10(2) Bq/L of Co-60, 2.01 x 10(-3) mol/L Cs, 9.10 x 10(-4) mol/L I and 1.04 x 10(-3) mol/L Br were injected into the borehole. The decrease of the radioisotope concentrations in the borehole was monitored using in situ gamma-spectrometry. The other tracers were analyzed with state-of-the-art laboratory procedures after sampling of small water aliquots from the reservoir. The diffusion experiment was carried out over a period of one year after which the interval section was overcored and analyzed. Based on the experimental data from the tracer evolution in the borehole and the tracer profiles in the rock, the diffusion of tracers was modelled with the numerical code CRUNCH. The results obtained for HTO (H-3), I- and Br- confirm previous lab and in situ diffusion data. Anionic fluxes into the formation were smaller compared to HTO because of anion exclusion effects. The migration of the cations Sr-85(2+), Cs+ and Co-60(2+) was found to be governed by both diffusion and sorption processes. For Sr-85(2+), the slightly higher diffusivity relative to HTO and the low sorption value are consistent with laboratory diffusion measurements on small-scale samples. In the case of Cs+, the numerically deduced high diffusivity and the Freundlich-type sorption behaviour is also supported by ongoing laboratory data. For Co, no laboratory diffusion data were yet available for comparison; however, the modelled data suggests that Co-60(2+) sorption was weaker than would be expected from available batch sorption data. Overall, the results demonstrate the feasibility of the experimental setup for obtaining high-quality diffusion data for conservative and sorbing tracers. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
REASONS FOR PERFORMING STUDY: There is limited information on potential diffusion of local anaesthetic solution after various diagnostic analgesic techniques of the proximal metacarpal region. OBJECTIVE: To document potential distribution of local anaesthetic solution following 4 techniques used for diagnostic analgesia of the proximal metacarpal region. METHODS: Radiodense contrast medium was injected around the lateral palmar or medial and lateral palmar metacarpal nerves in 8 mature horses, using 4 different techniques. Radiographs were obtained 0, 10 and 20 min after injection and were analysed subjectively. A mixture of radiodense contrast medium and methylene blue was injected into 4 cadaver limbs; the location of the contrast medium and dye was determined by radiography and dissection. RESULTS: Following perineural injection of the palmar metacarpal nerves, most of the contrast medium was distributed in an elongated pattern axial to the second and fourth metacarpal bones. The carpometacarpal joint was inadvertently penetrated in 4/8 limbs after injections of the palmar metacarpal nerves from medial and lateral approaches, and in 1/8 limbs when both injections were performed from the lateral approach. Following perineural injection of the lateral palmar nerve using a lateral approach, the contrast medium was diffusely distributed in all but one limb, in which the carpal sheath was inadvertently penetrated. In 5/8 limbs, following perineural injection of the lateral palmar nerve using a medial approach, the contrast medium diffused proximally to the distal third of the antebrachium. CONCLUSIONS AND POTENTIAL RELEVANCE: Inadvertent penetration of the carpometacarpal joint is common after perineural injection of the palmar metacarpal nerves, but less so if both palmar metacarpal nerves are injected using a lateral approach. Following injection of the lateral palmar nerve using a medial approach, the entire palmar aspect of the carpus may be desensitised.
Resumo:
Although magnetic resonance spectroscopy can be used as a unique tool to study molecular diffusion, it is rarely used to measure the diffusion properties of intramyocellular and extramyocellular lipids. Lipids have very low apparent diffusion coefficients (ADCs), which make these measurements difficult and necessitate strong diffusion gradients and long diffusion times. Consequence is that these measurements have inherently low signal-to-noise ratio and are prone to artifacts. The addition of physiological triggering and individual storage and processing of the spectra is seen to be a possible approach to maximize signal intensity and achieve high reproducibility of the experiments. Thus, the optimized measurement protocol was used to investigate the diffusion properties of lipids in human skeletal muscle in vivo. At a diffusion time of about 110 ms, intramyocellular lipids show a significantly lower ADC (2.0 × 10(-6) mm(2)/s, 95% confidence interval 1.10 × 10(-6) to 2.94 × 10(-6) mm(2)/s) than extramyocellular lipids (1.58 × 10(-5) mm(2)/s, 95% confidence interval 1.41 × 10(-5) to 1.75 × 10(-5) mm(2)/s). Because the chemical properties of both lipid pools can be assumed to be similar, the difference can only be attributed to restricted or severely hindered diffusion in the intramyocellular droplets.