11 resultados para device management

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A 76-year-old male patient was admitted for percutaneous left atrial appendage (LAA) closure because of chronic atrial fibrillation and a history of gastrointestinal bleeding under oral anticoagulation. The procedure was complicated by perforation of the LAA with the lobe of the closure device being placed in the pericardial space. Keeping access to the pericardial space with the delivery sheath, the LAA closure device was replaced by an atrial septal defect closure device to seal the perforation. Then the initial LAA closure device was reimplanted in a correct position. Needle pericardiocentesis was required but the subsequent course was uneventful.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Successful management of orthopaedic device-related infections requires combined surgical and antimicrobial therapy. Because of the heterogeneity of clinical situations, controlled trials are lacking. Although rational concepts for surgical treatment have been published, many aspects of antimicrobial therapy are still not well documented. In this review, some of these knowledge gaps are discussed, and rational arguments for initial parenteral treatment are presented. In addition, the interpretation of data regarding bone penetration is discussed. Whereas rifampin is now a standard combination partner in the treatment of staphylococcal infections, its role against other microorganisms is still unclear. Finally, in view of the increasing prevalence of methicillin-resistant staphylococci and their decreasing susceptibility to vancomycin, data are provided on linezolid and daptomycin, which can potentially be used in bone and joint infections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Symptomatic overdrainage in children with shunt-treated hydrocephalus represents one of the more difficult shunt-related diseases and may require repeated surgery. Gravity-assisted valve design has become a standard device to avoid overdrainage in many European pediatric hydrocephalus centers. However, the use of a gravitational valve for relieving symptoms associated with overdrainage has not yet been addressed. The goal of this study was to evaluate the effectiveness of a gravitational valve in the treatment of symptomatic overdrainage in children with shunts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Current pulsatile ventricular assist devices operate asynchronous with the left ventricle in fixed-rate or fill-to-empty modes because electrocardiogram-triggered modes have been abandoned. We hypothesize that varying the ejection delay in the synchronized mode yields more precise control of hemodynamics and left ventricular loading. This allows for a refined management that may be clinically beneficial. METHODS: Eight sheep received a Thoratec paracorporeal ventricular assist device (Thoratec Corp, Pleasanton, Calif) via ventriculo-aortic cannulation. Left ventricular pressure and volume, aortic pressure, pulmonary flow, pump chamber pressure, and pump inflow and outflow were recorded. The pump was driven by a clinical pneumatic drive unit (Medos Medizintechnik AG, Stolberg, Germany) synchronously with the native R-wave. The start of pump ejection was delayed between 0% and 100% of the cardiac period in 10% increments. For each of these delays, hemodynamic variables were compared with baseline data using paired t tests. RESULTS: The location of the minimum of stroke work was observed at a delay of 10% (soon after aortic valve opening), resulting in a median of 43% reduction in stroke work compared with baseline. Maximum stroke work occurred at a median delay of 70% with a median stroke work increase of 11% above baseline. Left ventricular volume unloading expressed by end-diastolic volume was most pronounced for copulsation (delay 0%). CONCLUSIONS: The timing of pump ejection in synchronized mode yields control over left ventricular energetics and can be a method to achieve gradual reloading of a recoverable left ventricle. The traditionally suggested counterpulsation is not optimal in ventriculo-aortic cannulation when maximum unloading is desired.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Arterial puncture closure devices (APCD) are frequently used after cardiac catheterization. Here, the diagnosis and therapy of femoral artery complications after the use of the Angio-Seal APCD is reported. PATIENTS AND METHODS: The Angio-Seal APCD was deployed in 1600 patients undergoing transfemoral catheterization. RESULTS: In 7 of 1600 cases (0.4%) vascular complications occurred following Angio-Seal deployment. Diagnosis was made by duplex sonography. Intraoperative findings consisted of a complete occlusion with dissection of the femoral artery in all patients. In 6 cases, the femoral bifurcation had to be reconstructed after endarterectomy. Follow-up is complete with a mean of 6 months. CONCLUSION: The Angio-Seal device should not be used for closure of the superficial femoral artery and in patients with severe arteriosclerosis. The application of arteriography as well as the use of ultrasound-guided puncture is advisable. In all cases, surgical intervention was successful and an adequate therapy for management of complications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In a 9-year-old boy, bridging to transplantation was successful with an external biventricular device, the Berlin Heart Excor (Berlin Heart, Berlin, Germany), during a 7-month period. Main long-term complications consisted of infection and hypercoagulability with clotting inside the chambers necessitating six pump exchanges, but without thromboembolic events. This report reviews hemostasis monitoring and management of long-term mechanical circulatory support.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is focused on the integration of state-of-the-art technologies in the fields of telecommunications, simulation algorithms, and data mining in order to develop a Type 1 diabetes patient's semi to fully-automated monitoring and management system. The main components of the system are a glucose measurement device, an insulin delivery system (insulin injection or insulin pumps), a mobile phone for the GPRS network, and a PDA or laptop for the Internet. In the medical environment, appropriate infrastructure for storage, analysis and visualizing of patients' data has been implemented to facilitate treatment design by health care experts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This case report describes the anesthetic and airways management of a dog affected by 4th degree tracheal collapse and undergoing endoscope-guided intraluminal stent placement. After premedication with acepromazine and butorphanol, general anesthesia was induced with propofol and maintained with intravenous propofol and butorphanol in constant rate infusion. During intraluminal stent placement, oxygen was supplemented by means of a simple and inexpensive handmade device, namely, a ureteral catheter inserted into the trachea and connected to an oxygen source, which allowed for the maintenance of airways’ patency and adequate patient’s oxygenation, without decreasing visibility in the surgical field or interfering with the procedure. The use of the technique described in the present paper was the main determinant of the successful anesthetic management and may be proposed for similar critical cases in which surgical manipulation of the tracheal lumen, which may potentially result in hypoxia by compromising airways patency, is required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a case of laparoscopic surgical management of an iatrogenic lymphorrhea using indocyanine green (ICG). A case of a patient who developed recurrent symptomatic lymphorrhea after laparoscopic radical hysterectomy and bilateral pelvic lymphadenectomy for an early stage cervical cancer is presented. Intraoperative bipedal interdigital subcutaneous injection of ICG exactly localized the disrupted lymphatic duct on fluorescence imaging performed with a near-infrared laparoscopic fluorescent optic device, thus allowing a successful surgical repair.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXT Radiolabelled choline positron emission tomography has changed the management of prostate cancer patients. However, new emerging radiopharmaceutical agents, like radiolabelled prostate specific membrane antigen, and new promising hybrid imaging will begin new challenges in the diagnostic field. OBJECTIVE The continuous evolution in nuclear medicine has led to the improvement in the detection of recurrent prostate cancer (PCa), particularly distant metastases. New horizons have been opened for radiolabelled choline positron emission tomography (PET)/computed tomography (CT) as a guide for salvage therapy or for the assessment of systemic therapies. In addition, new tracers and imaging tools have been recently tested, providing important information for the management of PCa patients. Herein we discuss: (1) the available evidence in literature on radiolabelled choline PET and their recent indications, (2) the role of alternative radiopharmaceutical agents, and (3) the advantages of a recent hybrid imaging device (PET/magnetic resonance imaging) in PCa. EVIDENCE ACQUISITION Data from recently published (2010-2015), original articles concerning the role of choline PET/CT, new emerging radiotracers, and a new imaging device are analysed. This review is reported according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. EVIDENCE SYNTHESIS In the restaging phase, the detection rate of choline PET varies between 4% and 97%, mainly depending on the site of recurrence and prostate-specific antigen levels. Both 68gallium (68Ga)-prostate specific membrane antigen and 18F-fluciclovine are shown to be more accurate in the detection of recurrent disease as compared with radiolabelled choline PET/CT. Particularly, Ga68-PSMA has a detection rate of 50% and 68%, respectively for prostate-specific antigen levels < 0.5ng/ml and 0.5-2ng/ml. Moreover, 68Ga- PSMA PET/magnetic resonance imaging demonstrated a particularly higher accuracy in detecting PCa than PET/CT. New tracers, such as radiolabelled bombesin or urokinase-type plasminogen activator receptor, are promising, but few data in clinical practice are available today. CONCLUSIONS Some limitations emerge from the published papers, both for radiolabelled choline PET/CT and also for new radiopharmaceutical agents. Efforts are still needed to enhance the impact of published data in the world of oncology, in particular when new radiopharmaceuticals are introduced into the clinical arena. PATIENT SUMMARY In the present review, the authors summarise the last evidences in clinical practice for the assessment of prostate cancer, by using nuclear medicine modalities, like positron emission tomography/computed tomography and positron emission tomography/magnetic resonance imaging.