14 resultados para device independent mobile learning

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have developed a haptic-based approach for retraining of interjoint coordination following stroke called time-independent functional training (TIFT) and implemented this mode in the ARMin III robotic exoskeleton. The ARMin III robot was developed by Drs. Robert Riener and Tobias Nef at the Swiss Federal Institute of Technology Zurich (Eidgenossische Technische Hochschule Zurich, or ETH Zurich), in Zurich, Switzerland. In the TIFT mode, the robot maintains arm movements within the proper kinematic trajectory via haptic walls at each joint. These arm movements focus training of interjoint coordination with highly intuitive real-time feedback of performance; arm movements advance within the trajectory only if their movement coordination is correct. In initial testing, 37 nondisabled subjects received a single session of learning of a complex pattern. Subjects were randomized to TIFT or visual demonstration or moved along with the robot as it moved though the pattern (time-dependent [TD] training). We examined visual demonstration to separate the effects of action observation on motor learning from the effects of the two haptic guidance methods. During these training trials, TIFT subjects reduced error and interaction forces between the robot and arm, while TD subject performance did not change. All groups showed significant learning of the trajectory during unassisted recall trials, but we observed no difference in learning between groups, possibly because this learning task is dominated by vision. Further testing in stroke populations is warranted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Arterial hypertension is a chronic disease with a therapeutical challenge for the patient and the physician involved. Patient-independent techniques with good efficacy and tolerability are wanted. The autonomous nervous system insufficiently therapeutically exploited to date, is now approachable by two types of intervention: renal nerve ablation, an endovascular approach without remaining foreign body, and BAT, baroreflex activating therapy using an implantable device stimulating the carotid sinus. The blood pressure lowering potency of BAT appears more than with renal nerve ablation and also clinical study data are more prevalent. With both treatment options the patients having the most profit are insufficiently defined. Given this knowledge, any form of secondary hypertension needs to be excluded beforehand.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Location-awareness indoors will be an inseparable feature of mobile services/applications in future wireless networks. Its current ubiquitous availability is still obstructed by technological challenges and privacy issues. We propose an innovative approach towards the concept of indoor positioning with main goal to develop a system that is self-learning and able to adapt to various radio propagation environments. The approach combines estimation of propagation conditions, subsequent appropriate channel modelling and optimisation feedback to the used positioning algorithm. Main advantages of the proposal are decreased system set-up effort, automatic re-calibration and increased precision.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The laser device DIAGNOdent developed for the detection of occlusal caries has limited value on approximal surfaces. The aim of this study was to develop and to test a new laser fluorescence (LF) device for the detection of approximal caries. Light with a wavelength of 655 nm was transported to the approximal surface using two different sapphire fibre tips. Seventy-five teeth were selected from a pool of extracted permanent human molars, frozen at -20 degrees C until use. Before being measured, they were defrosted, cleaned and calculus was removed with a scaler. The molars were set in blocks simulating the contact area of adults. Bitewing radiographs were obtained using Kodak Insight films. After two independent assessments with the new LF device, the teeth were histologically prepared, and assessed for caries extension. Using the laser, specificity values for D1 threshold (outer half of enamel), D2 threshold (inner half of enamel), D3 threshold (dentine) ranged between 0.81 and 0.93, sensitivity between 0.84 and 0.92 with no difference between the two tips. Bitewing radiography showed an inferior performance compared to LF (p<0.05). Intraex aminer reproducibility was high (kappa>.74). The new LF system might be a useful additional tool in detecting approximal caries. Because of its good reproducibility, it could be used to monitor caries regression or progression on approximal surfaces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The new device DIAGNOdent pen based on red laser light induced fluorescence was introduced for the detection of approximal and occlusal caries. The aim of this study was to test its performance on occlusal surfaces. The new device comes with two different sapphire fibre tips: a cylindrical tip and a conical tip. The two new sapphire fibre tips were used and compared with the tip currently available with DIAGNOdent (DD). METHODS: The teeth were selected from a pool of extracted permanent human molars, which were stored frozen at -20 degrees C, until use. Prior to being measured the teeth were defrosted and cleaned. One hundred and nineteen teeth were selected and measured with the old tip and with the two new tips of the new device by two independent assessments. The teeth were histologically prepared and assessed for caries extension. RESULTS: Specificity values for D(1), D(2) and D(3) ranged between 0.69 and 0.89, sensitivity between 0.78 and 0.96. There were no statistically significant differences obtained between the two tips of the new and the one tip of the old device (p>0.05). Intra-examiner reliability with kappa values of >0.83 was high. CONCLUSIONS: In this study, the new laser fluorescence device performed on occlusal surfaces as well as the available device.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a model of spike-driven synaptic plasticity inspired by experimental observations and motivated by the desire to build an electronic hardware device that can learn to classify complex stimuli in a semisupervised fashion. During training, patterns of activity are sequentially imposed on the input neurons, and an additional instructor signal drives the output neurons toward the desired activity. The network is made of integrate-and-fire neurons with constant leak and a floor. The synapses are bistable, and they are modified by the arrival of presynaptic spikes. The sign of the change is determined by both the depolarization and the state of a variable that integrates the postsynaptic action potentials. Following the training phase, the instructor signal is removed, and the output neurons are driven purely by the activity of the input neurons weighted by the plastic synapses. In the absence of stimulation, the synapses preserve their internal state indefinitely. Memories are also very robust to the disruptive action of spontaneous activity. A network of 2000 input neurons is shown to be able to classify correctly a large number (thousands) of highly overlapping patterns (300 classes of preprocessed Latex characters, 30 patterns per class, and a subset of the NIST characters data set) and to generalize with performances that are better than or comparable to those of artificial neural networks. Finally we show that the synaptic dynamics is compatible with many of the experimental observations on the induction of long-term modifications (spike-timing-dependent plasticity and its dependence on both the postsynaptic depolarization and the frequency of pre- and postsynaptic neurons).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Recurrent embolic events after device closure of patent foramen ovale (PFO) have been related to incomplete closure. Another cause could be atrial fibrillation (AF). The aim of this study was to determine the incidence of AF in stroke patients after PFO closure. METHODS: Consecutive patients with device closure of a PFO after a stroke or transient ischemic attack and control patients with stroke underwent 7-day event loop recordings 3 and 6 months after PFO closure or stroke, respectively. RESULTS: Forty patients treated by PFO device closure 96 +/- 68 days after cryptogenic ischemic stroke and 70 control patients with ischemic stroke of other etiologies (known AF excluded) were compared. AF was identified in 6 patients (15%) of the treated group and in 12 control patients (17%, p = 0.77). In multivariate analysis, the presence of an occluder device was not an independent risk factor for AF. CONCLUSIONS: The incidence of AF is high after device closure of a PFO in stroke patients and similar to that in patients with stroke of non-PFO etiology and, hence, with no device. Further studies are required to determine the risk of thromboembolism and the optimal treatment in patients developing AF after device closure of a PFO.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The C-Port System (Cardica, Inc, Redwood City, Calif) integrates in one tool all functions necessary to enable rapid automated distal coronary anastomoses. The goal of this prospective, nonrandomized, and multicenter study is to determine the safety and efficacy of this novel anastomotic system. METHODS: Five centers enrolled 133 patients awaiting elective coronary artery bypass grafting surgery. Outcome variables were intraoperative device performance, incidence of device-related adverse events, predischarge and 6-month angiographic graft patency, and 12-month clinical outcome. Independent core laboratories performed qualitative and quantitative angiographic and computed tomographic assessments. RESULTS: The C-Port was used to perform a vein-to-coronary anastomosis in 130 patients. Intraoperative conversion to a hand-sewn anastomosis was necessary in 11 patients because of inadequate target site preparation, inappropriate target vessel selection, or both. Inadequate blood flow related to poor runoff required conversion in 3 additional patients. Three patients died before discharge of causes unrelated to the device. At discharge, 113 patients had a C-Port implant in place, and 104 C-Port anastomoses were studied by means of angiography, resulting in 100 FitzGibbon A, 3 FitzGibbon B, and 1 FitzGibbon 0 classifications. At 6 months, one additional patient died of a device-unrelated cause, and 98 patients were evaluated by means of angiography (n = 89). Overall patency (FitzGibbon A) was 92.1%. Three C-Port anastomoses were rated FitzGibbon B, and 4 were rated FitzGibbon 0. At 12 months, 107 (98.2%) of 109 alive patients were followed up, without any reports of device-related major adverse cardiac events. CONCLUSIONS: The C-Port System allows for a rapid, reliable, and compliant distal anastomosis and yields favorable 6-month angiographic and 12-month clinical results when compared with published studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bilingual education programs implicitly assume that the acquired knowledge is represented in a language-independent way. This assumption, however, stands in strong contrast to research findings showing that information may be represented in a way closely tied to the specific language of instruction and learning. The present study aims to examine whether and to which extent cognitive costs appear during arithmetic learning when language of instruction and language of retrieving differ. Thirty-nine high school students participating in a bilingual education program underwent a four-day training on multiplication and subtraction problems in one language (German or French), followed by a test session in which they had to solve trained as well as untrained problems in both languages. We found that cognitive costs related to language switching appeared for both arithmetic operations. Implications of our findings are discussed with respect to bilingual education as well as to cognitive mechanisms underlying different arithmetic operations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The goal of this study was to investigate offline memory consolidation with regard to general motor skill learning and implicit sequence-specific learning. We trained young adults on a serial reaction time task with a retention interval of either 24 hours (Experiment 1) or 1 week (Experiment 2) between two sessions. We manipulated sequence complexity (deterministic vs. probabilistic) and motor responses (unimanual or vs. bimanual). We found no evidence of offline memory consolidation for sequencespecific learning with either interval (in the sense of no deterioration over the interval but no further improvement either). However, we did find evidence of offline enhancement of general motor skill learning with both intervals, independent of kind of sequence or kind of response. These results suggest that general motor skill learning, but not sequence-specific learning, appears to be enhanced during offline intervals in implicit sequence learning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Selectivity in encoding, aspects of attentional control and their contribution to learning performance were explored in a sample of preschoolers. While the children are performing a learning task, their encoding of relevant and attention towards irrelevant information was recorded through an eye-tracking device. Recognition of target items was used as measure of learning outcome, and individual differences in resistance to interference and inhibition of attention to task-irrelevant stimuli (i.e. distractibility) were used as measures of executive control of attention. Results indicated well-developed selectivity during encoding in young children. Recognition performance was related to selective encoding and aspects of attentional control, explaining individual differences in learning. Copyright © 2011 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Arterial waves are seen as possible independent mediators of cardiovascular risks, and the wave intensity analysis (WIA) has therefore been proposed as a method for patient selection for ventricular assist device (VAD) implantation. Interpreting measured wave intensity (WI) is challenging and complexity is increased by the implantation of a VAD. The waves generated by the VAD interact with the waves generated by the native heart, and this interaction varies with changing VAD settings. Eight sheep were implanted with a pulsatile VAD (PVAD) through ventriculo-aortic cannulation. The start of PVAD ejection was synchronized to the native R-wave and delayed between 0 % - 90 % of the cardiac cycle in 10 % steps or phase shifts (PS). Pressure and velocity signals were registered, using a combined Doppler and pressure wire positioned in the abdominal aorta, and used to calculate the WI. Depending on the PS, different wave interference phenomena occurred. Maximum unloading of the left ventricle (LV) coincided with constructive interference and maximum blood flow pulsatility, and maximum loading of the LV coincided with destructive interference and minimum blood flow pulsatility. We believe, that non-invasive WIA could potentially be used clinically to assess the mechanical load of the LV, and to monitor the peripheral hemodynamics such as blood flow pulsatility and risk of intestinal bleeding.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Web surveys are becoming increasingly popular in survey research. Compared with face-to-face, telephone and mail surveys, web surveys may contain a different and new source of measurement error and bias: the type of device that respondents use to answer the survey questions. To the best of our knowledge, this is the first study that tests whether the use of mobile devices affects survey characteristics and stated preferences in a web-based choice experiment. The web survey was carried out in Germany with 3,400 respondents, of which 12 per cent used a mobile device (i.e. tablet or smartphone), and comprised a stated choice experiment on externalities of renewable energy production using wind, solar and biomass. Our main finding is that survey characteristics such as interview length and acquiescence tendency are affected by the device used. In contrast to what might be expected, we find that, compared with respondents using desktop computers and laptops, mobile device users spent more time to answer the survey and are less likely to be prone to acquiescence bias. In the choice experiment, mobile device users tended to be more consistent in their stated choices, and there are differences in willingness to pay between both subsamples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Web surveys are becoming increasingly popular in survey research including stated preference surveys. Compared with face-to-face, telephone and mail surveys, web surveys may contain a different and new source of measurement error and bias: the type of device that respondents use to answer the survey questions. This is the first study that tests whether the use of mobile devices, tablets or smartphones, affects survey characteristics and stated preferences in a web-based choice experiment. The web survey on expanding renewable energy production in Germany was carried out with 3182 respondents, of which 12% used a mobile device. Propensity score matching is used to account for selection bias in the use of mobile devices for survey completion. We find that mobile device users spent more time than desktop/laptop users to answer the survey. Yet, desktop/laptop users and mobile device users do not differ in acquiescence tendency as an indicator of extreme response patterns. For mobile device users only, we find a negative correlation between screen size and interview length and a positive correlation between screen size and acquiescence tendency. In the choice experiment data, we do not find significant differences in the tendency to choose the status quo option and scale between both subsamples. However, some of the estimates of implicit prices differ, albeit not in a unidirectional fashion. Model results for mobile device users indicate a U-shaped relationship between error variance and screen size. Together, the results suggest that using mobile devices is not detrimental to survey quality.