40 resultados para definition

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because of advances in our understanding of the hypereosinophilic syndrome (HES) and the availability of novel therapeutic agents, the original criteria defining these disorders are becoming increasingly problematic. Here, we discuss shortcomings with the current definition of HES and recent developments in the classification of these disorders. Despite significant progress in our understanding of the pathogenesis of some forms of HES, the current state of knowledge is still insufficient to formulate a new comprehensive etiologic definition of HESs. Nevertheless, we suggest a new working definition that overcomes some of the most obvious limitations with the original definition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients with moderate to severe psoriasis are undertreated. To solve this persistent problem, the consensus programme was performed to define goals for treatment of plaque psoriasis with systemic therapy and to improve patient care. An expert consensus meeting and a collaborative Delphi procedure were carried out. Nineteen dermatologists from different European countries met for a face-to-face discussion and defined items through a four-round Delphi process. Severity of plaque psoriasis was graded into mild and moderate to severe disease. Mild disease was defined as body surface area (BSA) ≤10 and psoriasis area and severity index (PASI) ≤10 and dermatology life quality index (DLQI) ≤10 and moderate to severe psoriasis as (BSA > 10 or PASI > 10) and DLQI > 10. Special clinical situations may change mild psoriasis to moderate to severe including involvement of visible areas or severe nail involvement. For systemic therapy of plaque psoriasis two treatment phases were defined: (1) induction phase as the treatment period until week 16; however, depending on the type of drug and dose regimen used, this phase may be extended until week 24 and (2) maintenance phase for all drugs was defined as the treatment period after the induction phase. For the definition of treatment goals in plaque psoriasis, the change of PASI from baseline until the time of evaluation (ΔPASI) and the absolute DLQI were used. After induction and during maintenance therapy, treatment can be continued if reduction in PASI is ≥75%. The treatment regimen should be modified if improvement of PASI is <50%. In a situation where the therapeutic response improved ≥50% but <75%, as assessed by PASI, therapy should be modified if the DLQI is >5 but can be continued if the DLQI is ≤5. This programme defines the severity of plaque psoriasis for the first time using a formal consensus of 19 European experts. In addition, treatment goals for moderate to severe disease were established. Implementation of treatment goals in the daily management of psoriasis will improve patient care and mitigate the problem of undertreatment. It is planned to evaluate the implementation of these treatment goals in a subsequent programme involving patients and physicians.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the distribution of interleukin (IL)-1β, IL-6, tumour necrosis factor (TNF)-α and C-reactive protein (CRP) according to the different definitions of metabolically healthy obesity (MHO).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Early detection is a major goal in the management of malignant melanoma. Besides clinical assessment many noninvasive technologies such as dermoscopy, digital dermoscopy and in vivo laser scanner microscopy are used as additional methods. Herein we tested a system to assess lesional perfusion as a tool for early melanoma detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate high-definition and conventional oscillometry in comparison with direct blood pressure measurements in anaesthetised dogs. METHODS: Eight simultaneous readings for systolic, diastolic and mean pressure were obtained directly and with each of two devices in nine anaesthetised dogs. Measurement procedure and validation were based on the 2007 ACVIM guidelines. RESULTS: Sixty-three simultaneous readings were evaluated for each device and direct measurements. The mean differences (bias) to direct values were within 10 mmHg for both devices although bias for systolic and diastolic blood pressures was higher for Memodiagnostic. The standard deviations of differences (precision) were within 15 mmHg for Dinamap but exceeded for Memodiagnostic. Correlation coefficients were higher for Dinamap than Memodiagnostic but both failed to reach a correlation of 0.9. Over 50% of values lay within 10 mmHg of direct measures for both devices, but this percentage was greater for Dinamap than Memodiagnostic. Over 80% of values lay within 20 mmHg of direct measures for Dinamap but not for Memodiagnostic. CLINICAL SIGNIFICANCE: Both devices failed to meet ACVIM guideline validation. However, Dinamap only failed with regards to correlation. Memodiagnostic failed on several requirements, and based on poor correlation, accuracy and precision, this device cannot be currently recommended for dogs under anaesthesia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new generation of high definition computed tomography (HDCT) 64-slice devices complemented by a new iterative image reconstruction algorithm-adaptive statistical iterative reconstruction, offer substantially higher resolution compared to standard definition CT (SDCT) scanners. As high resolution confers higher noise we have compared image quality and radiation dose of coronary computed tomography angiography (CCTA) from HDCT versus SDCT. Consecutive patients (n = 93) underwent HDCT, and were compared to 93 patients who had previously undergone CCTA with SDCT matched for heart rate (HR), HR variability and body mass index (BMI). Tube voltage and current were adapted to the patient's BMI, using identical protocols in both groups. The image quality of all CCTA scans was evaluated by two independent readers in all coronary segments using a 4-point scale (1, excellent image quality; 2, blurring of the vessel wall; 3, image with artefacts but evaluative; 4, non-evaluative). Effective radiation dose was calculated from DLP multiplied by a conversion factor (0.014 mSv/mGy × cm). The mean image quality score from HDCT versus SDCT was comparable (2.02 ± 0.68 vs. 2.00 ± 0.76). Mean effective radiation dose did not significantly differ between HDCT (1.7 ± 0.6 mSv, range 1.0-3.7 mSv) and SDCT (1.9 ± 0.8 mSv, range 0.8-5.5 mSv; P = n.s.). HDCT scanners allow low-dose 64-slice CCTA scanning with higher resolution than SDCT but maintained image quality and equally low radiation dose. Whether this will translate into higher accuracy of HDCT for CAD detection remains to be evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a case of a 34-year-old woman who had a left anterior wall myocardial infarction develop in the first trimester of pregnancy. Despite urgent and successful revascularization, she demonstrated persistent segmental wall motion abnormalities by transthoracic echocardiography. To manage this patient safely through pregnancy with a better definition of myocardium at risk, a cardiac magnetic resonance examination was performed. This identified a large territory of acutely edematous myocardium in addition to providing accurate volumetric measurements of left ventricular size and function. Because of her gravid state, gadolinium was not administered nor was it required to delineate the region of myocardium at risk.