3 resultados para current solution

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To evaluate the effect of automatic tube current modulation on radiation dose and image quality for low tube voltage computed tomography (CT) angiography. MATERIALS AND METHODS: An anthropomorphic phantom was scanned with a 64-section CT scanner using following tube voltages: 140 kVp (Protocol A), 120 kVp (Protocol B), 100 kVp (Protocol C), and 80 kVp (Protocol D). To achieve similar noise, combined z-axis and xy-axes automatic tube current modulation was applied. Effective dose (ED) for the four tube voltages was assessed. Three plastic vials filled with different concentrations of iodinated solution were placed on the phantom's abdomen to obtain attenuation measurements. The signal-to-noise ratio (SNR) was calculated and a figure of merit (FOM) for each iodinated solution was computed as SNR(2)/ED. RESULTS: The ED was kept similar for the four different tube voltages: (A) 5.4 mSv +/- 0.3, (B) 4.1 mSv +/- 0.6, (C) 3.9 mSv +/- 0.5, and (D) 4.2 mSv +/- 0.3 (P > .05). As the tube voltage decreased from 140 to 80 kVp, image noise was maintained (range, 13.8-14.9 HU) (P > .05). SNR increased as the tube voltage decreased, with an overall gain of 119% for the 80-kVp compared to the 140-kVp protocol (P < .05). The FOM results indicated that with a reduction of the tube voltage from 140 to 120, 100, and 80 kVp, at constant SNR, ED was reduced by a factor of 2.1, 3.3, and 5.1, respectively, (P < .001). CONCLUSIONS: As tube voltage decreases, automatic tube current modulation for CT angiography yields either a significant increase in image quality at constant radiation dose or a significant decrease in radiation dose at a constant image quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Images of an object under different illumination are known to provide strong cues about the object surface. A mathematical formalization of how to recover the normal map of such a surface leads to the so-called uncalibrated photometric stereo problem. In the simplest instance, this problem can be reduced to the task of identifying only three parameters: the so-called generalized bas-relief (GBR) ambiguity. The challenge is to find additional general assumptions about the object, that identify these parameters uniquely. Current approaches are not consistent, i.e., they provide different solutions when run multiple times on the same data. To address this limitation, we propose exploiting local diffuse reflectance (LDR) maxima, i.e., points in the scene where the normal vector is parallel to the illumination direction (see Fig. 1). We demonstrate several noteworthy properties of these maxima: a closed-form solution, computational efficiency and GBR consistency. An LDR maximum yields a simple closed-form solution corresponding to a semi-circle in the GBR parameters space (see Fig. 2); because as few as two diffuse maxima in different images identify a unique solution, the identification of the GBR parameters can be achieved very efficiently; finally, the algorithm is consistent as it always returns the same solution given the same data. Our algorithm is also remarkably robust: It can obtain an accurate estimate of the GBR parameters even with extremely high levels of outliers in the detected maxima (up to 80 % of the observations). The method is validated on real data and achieves state-of-the-art results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The optimal crystalloid solution to use perioperatively in patients undergoing open radical cystectomy remains unclear. Many of the fluids used for intravenous hydration contain supraphysiologic concentrations of chloride, which can induce hyperchloremia and metabolic acidosis, resulting in renal vasoconstriction and decreased renal function. In addition, patients receiving less fluid and less sodium show faster recovery of gastrointestinal (GI) function after colonic surgery. METHODS AND DESIGN This is an investigator-initiated, single-center, randomized, controlled, parallel group trial with assessor-blinded outcome assessment, in the Department of Urology, University Hospital Bern, Switzerland. The study will involve 44 patients with bladder cancer scheduled for radical cystectomy and urinary diversion. The primary outcome is the duration between the end of surgery and the return of the GI function (first defecation). Secondary outcomes are fluid balance (body weight difference postoperatively versus preoperatively) and the incidence of kidney function disorders according to the Risk-Injury-Failure-Loss-End Stage Renal Disease (RIFLE classification). An equal number of patients are allocated to receive Ringerfundin® solution or a glucose/potassium-based balanced crystalloid solution as baseline infusion during the entire time that intravenous administration of fluid is necessary during the perioperative period. The randomized crystalloid solution is infused at a rate of 1 ml/kg/h until the bladder has been removed, followed by 3 ml/kg/h until the end of surgery. Postoperative hydration is identical in both groups and consists of 1,500 ml of the randomized crystalloid solution per 24 hours. Postoperative patient care is identical in both groups; patients are allowed to drink clear fluids immediately after surgery, and liquid diet is started on postoperative day 1, as well as active mobilization and the use of chewing gum. Body weight is measured daily in the morning. Time of first flatus and first defecation are recorded. DISCUSSION This trial assesses the benefits and harms of two different balanced crystalloid solutions for perioperative fluid management in patients undergoing open radical cystectomy with urinary diversion, with regard to return of GI function and effects on postoperative renal function. TRIAL REGISTRATION Current Controlled Trials ISRCTN32976792 (registered on November 21 2013).