32 resultados para creep behaviour of rocks
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Trace element behavior during hydrous melting of a metasomatized garnet–peridotite was examined at pressures of 4–6 GPa and temperatures of 1000 °C–1200 °C, conditions appropriate for fluid penetrating the mantle wedge atop the subducting slab. Experiments were performed in a rocking multi-anvil apparatus using a diamond-trap setup. The compositions of the fluid and melt phases were measured using the cryogenic LA-ICP-MS technique. The water-saturated solidus of the K-lherzolite composition is located between 900 °C and 1000 °C at 4 GPa and between 1000 °C and 1100 °C at 5 and 6 GPa. The partition coefficients between fluid or melt and clinopyroxene reveal an asymmetric MREE trough with a minimum at Dy. The clinopyroxene in equilibrium with aqueous fluids is characterized by DUfluid–cpx > DThfluid–cpx while DUmelt–cpx tends to be similar to DThmelt–cpx. The partition coefficients between fluid or melt and garnet reveal very strong light to heavy REE fractionation, DLa/DLu from 95 (hydrous melt) to 1600 (aqueous fluid). The LILE are highly incompatible with partition coefficients > 50. The behavior of HFSE are decoupled, with DZr,Hf close to 1 while DNb,Ta > 10. Garnet is characterized by DUmelt/fluid–garnet < DThmelt/fluid–garnet. A comparison of our experimental partitioning results for trivalent cations as well as the results from the literature and the calculations carried out using the lattice strain model adapted to the presence of water in the bulk system indicates that H2O in the fluid or melt phase has a prominent effect on trace element partitioning. Garnet in mantle rocks in equilibrium with an aqueous fluid is characterized by significantly higher Do(3 +) for REE in the X site of the garnet compared with the partitioning values of the optimal cation in garnet in equilibrium with hydrous melts. Our data show for the first time that the change in the nature of the mobile phase (fluid vs. melt) does affect the affinities of trace elements into the garnet crystal at conditions below the second critical endpoint of the system. The same also applies for clinopyroxene, although this is less clear. Consequently, our new data allow for refinements in predictive modeling of element transfer from the slab to the mantle wedge and of possible compositions of metasomatized mantle that sources OIB magmatism.
Resumo:
Wear of attachments leads to a loss of retention and reduces the function of overdentures. This study evaluated the retention force changes of an attachment system for overdentures. The influence of the lubricant and the alloy on wear constancy was examined.
Resumo:
Because the recommendation to use flowables for posterior restorations is still a matter of debate, the objective of this study was to determine in a nationwide survey in Germany how frequently, for what indications, and for what reasons, German dentists use flowable composites in posterior teeth. In addition, the acceptance of a simplified filling technique for posterior restorations using a low stress flowable composite was evaluated. Completed questionnaires from all over Germany were returned by 1,449 dentists resulting in a response rate of 48.5%; 78.6% of whom regularly used flowable composites for posterior restorations. The most frequent indications were cavity lining (80.1%) and small Class I fillings (74.2%). Flowables were less frequently used for small Class II fillings (22.7%) or other indications (13.6%). Most frequent reasons given for the use of flowables in posterior teeth were the prevention of voids (71.7%) and superior adaptation to cavity walls (72.9%), whereas saving time was considered less important (13.8%). Based on the subjective opinion of the dentists the simplified filling technique seemed to deliver advantages compared to the methods used to date particularly with regard to good cavity adaptation and ease of use. In conclusion, resin composites are the standard material type used for posterior restorations by general dental practitioners in Germany and most dentists use flowable composites as liners.
Resumo:
Low rates of nest acceptance by laying hens are a major problem in commercial poultry farming operations with aviary systems, leading to costly manual collection and cleaning of mislaid eggs. To gain knowledge about factors affecting nest use, laying hens' preferences for different nest locations were tested. Nests are normally installed at one of two sites: against a wall of the hen house or integrated into one tier of the aviary rack The preferences of laying hens for different nest sites have never been examined under commercial conditions. The aim of this study is to investigate whether behavioural differences can be detected between the different nest sites. The study consists of two consecutive trials involving 5027 Lohmann Selected Leghorn hens (LSL) and 601 layer hybrids selected for extensive housing conditions (EXT). The hens were randomly assigned to eight compartments per trial in groups of 355-360 LSL or 300 EXT in a laying hen house. Four compartments were equipped with a Volito Voletage (R) aviary system (VV), and four were equipped with a Rihs Bolegell (R) aviary system (RB), both of which contained either integrated or wall-placed nests when the experiments started. A strongly balanced crossover design with four periods was used. At 36, 44 and 52 weeks of age, the nest site in four out of the eight compartments was switched. Before each change, the fronts of half of the nests were videotaped during the light period, and the behaviour throughout the main laying period was analysed. Furthermore, the numbers of nest eggs and mislaid eggs in each compartment were recorded every day. No differences in the number of mislaid eggs between the two nest sites could be detected, except at the age of 20/21 weeks when hens in VV aviaries mislaid more eggs when nests were integrated (P = 0.0012). More hens stood simultaneously in front of the integrated nests than in front of wall-placed nests (P = 0.015). Activity of the laying hens increased (P = 0.0073), and stationary behavioural patterns declined (P = 0.0093), when the nests were placed by the wall. Hens inspected integrated nests for a longer duration than wall-placed nests, but wall-placed nests were visited more frequently. In addition to the nest site, the width of the platform in front of the nest influenced laying hen behaviour. Compared with narrower platforms, balance movements decreased on wider ones. Additionally, the platform design had to be taken into account as well, given that hens could not stand or walk as securely on wooden slats as on a grid floor. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Polyetheretherketone (PEEK) is a novel polymer with potential advantages for its use in demanding orthopaedic applications (e.g. intervertebral cages). However, the influence of a physiological environment on the mechanical stability of PEEK has not been reported. Furthermore, the suitability of the polymer for use in highly stressed spinal implants such as intervertebral cages has not been investigated. Therefore, a combined experimental and analytical study was performed to address these open questions. A quasi-static mechanical compression test was performed to compare the initial mechanical properties of PEEK-OPTIMA polymer in a dry, room-temperature and in an aqueous, 37 degrees C environment (n=10 per group). The creep behaviour of cylindrical PEEK polymer specimens (n=6) was measured in a simulated physiological environment at an applied stress level of 10 MPa for a loading duration of 2000 hours (12 weeks). To compare the biomechanical performance of different intervertebral cage types made from PEEK and titanium under complex loading conditions, a three-dimensional finite element model of a functional spinal unit was created. The elastic modulus of PEEK polymer specimens in a physiological environment was 1.8% lower than that of specimens tested at dry, room temperature conditions (P<0.001). The results from the creep test showed an average creep strain of less than 0.1% after 2000 hours of loading. The finite element analysis demonstrated high strain and stress concentrations at the bone/implant interface, emphasizing the importance of cage geometry for load distribution. The stress and strain maxima in the implants were well below the material strength limits of PEEK. In summary, the experimental results verified the mechanical stability of the PEEK-OPTIMA polymer in a simulated physiological environment, and over extended loading periods. Finite element analysis supported the use of PEEK-OPTIMA for load-bearing intervertebral implants.
Resumo:
This is a retrospective clinical, radiological and patient outcome assessment of 21 consecutive patients with King 1 idiopathic adolescent scoliosis treated by short anterior selective fusion of the major thoracolumbar/lumbar (TL/L) curve. Three-dimensional changes of both curves, changes in trunk balance and rib hump were evaluated. The minimal follow-up was 24 months (max. 83). The Cobb angle of the TL/L curve was 52 degrees (45-67 degrees) with a flexibility of 72% (40-100%). The average length of the main curve was 5 (3-8) segments. An average of 3 (2-4) segments was fused using rigid single rod implants with side-loading screws. The Cobb angle of the thoracic curve was 33 degrees (18-50 degrees) with a flexibility of 69% (29-100%). The thoracic curve in bending was less than 20 degrees in 17 patients, and 20-25 degrees in 4 patients. In the TL/L curve there was an improvement of the Cobb angle of 67%, of the apex vertebral rotation of 51% and of the apex vertebral translation of 74%. The Cobb angle of the thoracic curve improved 29% spontaneously. Shoulder balance improved significantly from an average preoperative imbalance of 14.5-3.1 mm at the last follow-up. Seventy-five percent of the patients with preoperative positive shoulder imbalance (higher on the side of the thoracic curve) had levelled shoulders at the last follow-up. C7 offset improved from a preoperative 19.8 (0-40) to 4.8 (0-18) mm at the last follow-up. There were no significant changes in rotation, translation of the thoracic curve and the clinical rib hump. There were no significant changes in thoracic kyphosis or lumbar lordosis. The average score of the SRS-24 questionnaire at the last follow-up was 91 points (max. 120). We conclude that short anterior selective fusion of the TL/L curve in King 1 scoliosis with a thoracic curve bending to 25 degrees or less (Type 5 according to Lenke classification) results in a satisfactory correction and a balanced spine. Short fusions leave enough mobile lumbar segments for the establishment of global spinal balance. A positive shoulder imbalance is not a contraindication for this procedure. Structural interbody grafts are not necessary to maintain lumbar lordosis.