26 resultados para conductive

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The level of improvement in the audiological results of Baha(®) users mainly depends on the patient's preoperative hearing thresholds and the type of Baha sound processor used. This investigation shows correlations between the preoperative hearing threshold and postoperative aided thresholds and audiological results in speech understanding in quiet of 84 Baha users with unilateral conductive hearing loss, bilateral conductive hearing loss and bilateral mixed hearing loss. Secondly, speech understanding in noise of 26 Baha users with different Baha sound processors (Compact, Divino, and BP100) is investigated. Linear regression between aided sound field thresholds and bone conduction (BC) thresholds of the better ear shows highest correlation coefficients and the steepest slope. Differences between better BC thresholds and aided sound field thresholds are smallest for mid-frequencies (1 and 2 kHz) and become larger at 0.5 and 4 kHz. For Baha users, the gain in speech recognition in quiet can be expected to lie in the order of magnitude of the gain in their hearing threshold. Compared to its predecessor sound processors Baha(®) Compact and Baha(®) Divino, Baha(®) BP100 improves speech understanding in noise significantly by +0.9 to +4.6 dB signal-to-noise ratio, depending on the setting and the use of directional microphone. For Baha users with unilateral and bilateral conductive hearing loss and bilateral mixed hearing loss, audiological results in aided sound field thresholds can be estimated with the better BC hearing threshold. The benefit in speech understanding in quiet can be expected to be similar to the gain in their sound field hearing threshold. The most recent technology of Baha sound processor improves speech understanding in noise by an order of magnitude that is well perceived by users and which can be very useful in everyday life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare the patient benefit of the Bone-Anchored Hearing Aid (Baha) Divino and the Baha BP100 sound processors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nose-ear-throat manifestations of immunodeficiency disorders represent a diagnostic challenge for clinicians as these diseases often constitute the initial sign for connective disorders or autoimmune disease. The history of chronic rhinosinusitis and conductive hearing loss is often non specific. Therefore attention to an HLA class I deficiency must be considered if the disease has not been diagnosed on routine examination. One of the syndromes is due to a defective TAP complex, the peptide transporter complex associated with antigen presentation. Herein, we report two sisters with TAP-deficiency. The treatment of choice for TAP-deficient patients is conservative.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Insulated atomic force microscopy probes carrying gold conductive tips were fabricated and employed as bifunctional force and current sensors in electrolyte solutions under electrochemical potential control. The application of the probes for current-sensing imaging, force and current–distance spectroscopy as well as scanning electrochemical microscopy experiments was demonstrated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This review covers the surgery for the bone-anchored hearing aid (Baha(®)). PREOPERATIVE WORKUP: A review of the indications and preoperative diagnostics shows that best results are generally obtained in patients with conductive or mixed hearing loss rehabilitation when surgery is not applicable or has failed and in patients that suffer from single-sided deafness. An audiogram must confirm that the bone conduction hearing is within the inclusion criteria. A computed tomography scan is performed in cases of malformation to assure sufficient bone thickness at the site of screw implantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In cystic fibrosis (CF), tests for ventilation inhomogeneity are sensitive but not established for clinical routine. We assessed feasibility of a new double-tracer gas single-breath washout (SBW) in school-aged children with CF and control subjects, and compared SBW between groups and with multiple-breath nitrogen washout (MBNW). Three SBW and MBNW were performed in 118 children (66 with CF) using a side-stream ultrasonic flowmeter setup. The double-tracer gas containing 5% sulfur hexafluoride and 26.3% helium was applied during one tidal breath. Outcomes were SBW phase III slope (SIII(DTG)), MBNW-derived lung clearance index (LCI), and indices of acinar (S(acin)) and conductive (S(cond)) ventilation inhomogeneity. SBW took significantly less time to perform than MBNW. SBW and MBNW were feasible in 109 (92.4%) and 98 (83.0%) children, respectively. SIII(DTG) differed between children with CF and controls, mean±sd was -456.7±492.8 and -88.4±129.1 mg·mol·L(-1), respectively. Abnormal SIII(DTG) was present in 36 (59%) children with CF. SIII(DTG) was associated with LCI (r= -0.58) and S(acin) (r= -0.58), but not with S(cond). In CF, steeply sloping SIII(DTG) potentially reflects ventilation inhomogeneity near the acinus entrance. This tidal SBW is a promising test to assess ventilation inhomogeneity in an easy and fast way.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONCLUSIONS: Speech understanding is better with the Baha Divino than with the Baha Compact in competing noise from the rear. No difference was found for speech understanding in quiet. Subjectively, overall sound quality and speech understanding were rated better for the Baha Divino. OBJECTIVES: To compare speech understanding in quiet and in noise and subjective ratings for two different bone-anchored hearing aids: the recently developed Baha Divino and the Baha Compact. PATIENTS AND METHODS: Seven adults with bilateral conductive or mixed hearing losses who were users of a bone-anchored hearing aid were tested with the Baha Compact in quiet and in noise. Tests were repeated after 3 months of use with the Baha Divino. RESULTS: There was no significant difference between the two types of Baha for speech understanding in quiet when tested with German numbers and monosyllabic words at presentation levels between 50 and 80 dB. For speech understanding in noise, an advantage of 2.3 dB for the Baha Divino vs the Baha Compact was found, if noise was emitted from a loudspeaker to the rear of the listener and the directional microphone noise reduction system was activated. Subjectively, the Baha Divino was rated statistically significantly better in terms of overall sound quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: It was the aim of this study to investigate the prevalence of otologic manifestations in a cohort of Samter's syndrome patients (nasal polyps with chronic rhinosinusitis, aspirin intolerance and asthma). METHODS: We analyzed a retrospective and prospective case review from 1995 to 2005, performed in the otorhinolaryngology outpatient clinic of a tertiary referral center. Ear history, clinical examinations, treatment and outcome were evaluated using office and hospital records in 23 cases. All subjects completed a questionnaire. RESULTS: In 6 cases (26%), otological manifestations with ear pressure and conductive hearing loss occurred during an advanced stage of Samter's syndrome (>5 years after onset of the first nasal symptoms) partially responsive to systemic steroids. CONCLUSION: Recognition of the association between Samter's syndrome and otological disease is important (26% of the cases) because it could also be responsive to systemic steroids which prevent progression to irreversible hearing loss or infectious otomastoiditis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: External auditory canal cholesteatoma (EACC) is a rarity. Although there have been numerous case reports, there are only few systematic analyses of case series, and the pathogenesis of idiopathic EACC remains enigmatic. STUDY DESIGN: In a tertiary referral center for a population of 1.5 million inhabitants, 34 patients with 35 EACC (13 idiopathic [1 bilateral] and 22 secondary) who were treated between 1994 and 2006 were included in the study. RESULTS: EACC cardinal symptoms were longstanding otorrhea (65%) and dull otalgia (12%). Focal bone destruction in the external auditory canal with retained squamous debris and an intact tympanic membrane were characteristic. Only 27% of the patients showed conductive hearing loss exceeding 20 dB. Patients with idiopathic EACC had lesions typically located on the floor of the external auditory canal and were older, and the mean smoking intensity was also greater (p < 0.05) compared with patients with secondary EACC. The secondary lesions were assigned to categories (poststenotic [n = 6], postoperative [n = 6], and posttraumatic EACC [n = 4]) and rare categories (radiogenic [n = 2], postinflammatory [n = 1], and postobstructive EACC [n = 1]). In addition, we describe 2 patients with EACC secondary to the complete remission of a Langerhans cell histiocytosis of the external auditory canal. Thirty of 34 patients were treated surgically and became all free of recurrence, even after extensive disease. DISCUSSION: For the development of idiopathic EACC, repeated microtrauma (e.g., microtrauma resulting from cotton-tipped applicator abuse or from hearing aids) and diminished microcirculation (e.g., from smoking) might be risk factors. A location other than in the inferior portion of the external auditory canal indicates a secondary form of the disease, as in the case of 2 patients with atypically located EACC after years of complete remission of Langerhans cell histiocytosis, which we consider as a new posttumorous category and specific late complication of this rare disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To investigate correlations between preoperative hearing thresholds and postoperative aided thresholds and speech understanding of users of Bone-anchored Hearing Aids (BAHA). Such correlations may be useful to estimate the postoperative outcome with BAHA from preoperative data. STUDY DESIGN: Retrospective case review. SETTING: Tertiary referral center. PATIENTS:: Ninety-two adult unilaterally implanted BAHA users in 3 groups: (A) 24 subjects with a unilateral conductive hearing loss, (B) 38 subjects with a bilateral conductive hearing loss, and (C) 30 subjects with single-sided deafness. INTERVENTIONS: Preoperative air-conduction and bone-conduction thresholds and 3-month postoperative aided and unaided sound-field thresholds as well as speech understanding using German 2-digit numbers and monosyllabic words were measured and analyzed. MAIN OUTCOME MEASURES: Correlation between preoperative air-conduction and bone-conduction thresholds of the better and of the poorer ear and postoperative aided thresholds as well as correlations between gain in sound-field threshold and gain in speech understanding. RESULTS: Aided postoperative sound-field thresholds correlate best with BC threshold of the better ear (correlation coefficients, r2 = 0.237 to 0.419, p = 0.0006 to 0.0064, depending on the group of subjects). Improvements in sound-field threshold correspond to improvements in speech understanding. CONCLUSION: When estimating expected postoperative aided sound-field thresholds of BAHA users from preoperative hearing thresholds, the BC threshold of the better ear should be used. For the patient groups considered, speech understanding in quiet can be estimated from the improvement in sound-field thresholds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To compare speech understanding of the BAHA BP110 and BAHA Intenso sound processors. STUDY DESIGN Prospective experimental study. SETTING Tertiary referral center. PATIENTS Twenty experienced user of osseointegrated auditory implants with conductive or mixed hearing loss. INTERVENTIONS In a first session, half of the participants were fitted with an Intenso, the other half with a BP110. After 1 month of use, aided speech understanding in quiet and in noise was measured, and the other test processor was fitted. One month later, speech understanding with the second sound processor was assessed. MAIN OUTCOME MEASURES Speech understanding in quiet and in noise, with noise arriving either from the front, the rear, or the side of the user with the osseointegrated bone conductor. RESULTS Significant improvements were found for both processors for speech understanding in quiet (+9.6 to +34.8 percent points; p = 0.02 to 0.001) and in noise (+6.2 to +13.8 dB, p < 0.001). No significant differences were found between the 2 devices for speech in quiet. For noise from the rear, subjects were able to understand speech at signal-to-noise ratios which were lower (less favorable) by -5.1 dB (p < 0.001) when compared with the Intenso. CONCLUSION Speech understanding is substantially improved by both devices, with no significant differences between the sound processors in quiet. In noise, speech understanding is significantly better with the BP110 when compared to the Intenso for noise from the rear.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Poly(ɛ)caprolactone scaffolds have been electrospun directly into an auricular shaped conductive mould. Bovine chondrocytes were harvested from articular cartilage and seeded onto 16 of the produced scaffolds, which received either an ethanol (group A) or a plasma treatment (group B) for sterilisation before seeding. The seeded scaffolds were cultured for 3 weeks in vitro and analysed with regard to total DNA and GAG content as well as the expression of AGG, COL1, COL2, MMP3 and MMP13. Rapid cell proliferation and GAG accumulation was observed until week 2. However, total DNA and GAG content decreased again in week 3. qPCR data shows a slight increase in the expression of anabolic genes and a slight decrease for the catabolic genes, with a significant difference between the groups A and B only for COL2 and MMP13.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A close to native structure of bulk biological specimens can be imaged by cryo-electron microscopy of vitreous sections (CEMOVIS). In some cases structural information can be combined with X-ray data leading to atomic resolution in situ. However, CEMOVIS is not routinely used. The two critical steps consist of producing a frozen section ribbon of a few millimeters in length and transferring the ribbon onto an electron microscopy grid. During these steps, the first sections of the ribbon are wrapped around an eyelash (unwrapping is frequent). When a ribbon is sufficiently attached to the eyelash, the operator must guide the nascent ribbon. Steady hands are required. Shaking or overstretching may break the ribbon. In turn, the ribbon immediately wraps around itself or flies away and thereby becomes unusable. Micromanipulators for eyelashes and grids as well as ionizers to attach section ribbons to grids were proposed. The rate of successful ribbon collection, however, remained low for most operators. Here we present a setup composed of two micromanipulators. One of the micromanipulators guides an electrically conductive fiber to which the ribbon sticks with unprecedented efficiency in comparison to a not conductive eyelash. The second micromanipulator positions the grid beneath the newly formed section ribbon and with the help of an ionizer the ribbon is attached to the grid. Although manipulations are greatly facilitated, sectioning artifacts remain but the likelihood to investigate high quality sections is significantly increased due to the large number of sections that can be produced with the reported tool.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bone Anchored Hearing Implants (BAHI) are routinely used in patients with conductive or mixed hearing loss, e.g. if conventional air conduction hearing aids cannot be used. New sound processors and new fitting software now allow the adjustment of parameters such as loudness compression ratios or maximum power output separately. Today it is unclear, how the choice of these parameters influences aided speech understanding in BAHI users. In this prospective experimental study, the effect of varying the compression ratio and lowering the maximum power output in a BAHI were investigated. Twelve experienced adult subjects with a mixed hearing loss participated in this study. Four different compression ratios (1.0; 1.3; 1.6; 2.0) were tested along with two different maximum power output settings, resulting in a total of eight different programs. Each participant tested each program during two weeks. A blinded Latin square design was used to minimize bias. For each of the eight programs, speech understanding in quiet and in noise was assessed. For speech in quiet, the Freiburg number test and the Freiburg monosyllabic word test at 50, 65, and 80 dB SPL were used. For speech in noise, the Oldenburg sentence test was administered. Speech understanding in quiet and in noise was improved significantly in the aided condition in any program, when compared to the unaided condition. However, no significant differences were found between any of the eight programs. In contrast, on a subjective level there was a significant preference for medium compression ratios of 1.3 to 1.6 and higher maximum power output.