6 resultados para clinical errors
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
BACKGROUND Critical incidents in clinical medicine can have far-reaching consequences on patient health. In cases of severe medical errors they can seriously harm the patient or even lead to death. The involvement in such an event can result in a stress reaction, a so-called acute posttraumatic stress disorder in the healthcare provider, the so-called second victim of an adverse event. Psychological distress may not only have a long lasting impact on quality of life of the physician or caregiver involved but it may also affect the ability to provide safe patient care in the aftermath of adverse events. METHODS A literature review was performed to obtain information on care giver responses to medical errors and to determine possible supportive strategies to mitigate negative consequences of an adverse event on the second victim. An internet search and a search in Medline/Pubmed for scientific studies were conducted using the key words "second victim, "medical error", "critical incident stress management" (CISM) and "critical incident stress reporting system" (CIRS). Sources from academic medical societies and public institutions which offer crisis management programs where analyzed. The data were sorted by main categories and relevance for hospitals. Analysis was carried out using descriptive measures. RESULTS In disaster medicine and aviation navigation services the implementation of a CISM program is an efficient intervention to help staff to recover after a traumatic event and to return to normal functioning and behavior. Several other concepts for a clinical crisis management plan were identified. CONCLUSIONS The integration of CISM and CISM-related programs in a clinical setting may provide efficient support in an acute crisis and may help the caregiver to deal effectively with future error events and employee safety.
Resumo:
The planning of refractive surgical interventions is a challenging task. Numerical modeling has been proposed as a solution to support surgical intervention and predict the visual acuity, but validation on patient specific intervention is missing. The purpose of this study was to validate the numerical predictions of the post-operative corneal topography induced by the incisions required for cataract surgery. The corneal topography of 13 patients was assessed preoperatively and postoperatively (1-day and 30-day follow-up) with a Pentacam tomography device. The preoperatively acquired geometric corneal topography – anterior, posterior and pachymetry data – was used to build patient-specific finite element models. For each patient, the effects of the cataract incisions were simulated numerically and the resulting corneal surfaces were compared to the clinical postoperative measurements at one day and at 30-days follow up. Results showed that the model was able to reproduce experimental measurements with an error on the surgically induced sphere of 0.38D one day postoperatively and 0.19D 30 days postoperatively. The standard deviation of the surgically induced cylinder was 0.54D at the first postoperative day and 0.38D 30 days postoperatively. The prediction errors in surface elevation and curvature were below the topography measurement device accuracy of ±5μm and ±0.25D after the 30-day follow-up. The results showed that finite element simulations of corneal biomechanics are able to predict post cataract surgery within topography measurement device accuracy. We can conclude that the numerical simulation can become a valuable tool to plan corneal incisions in cataract surgery and other ophthalmosurgical procedures in order to optimize patients' refractive outcome and visual function.
Resumo:
PURPOSE The range of patient setup errors in six dimensions detected in clinical routine for cranial as well as for extracranial treatments, were analyzed while performing linear accelerator based stereotactic treatments with frameless patient setup systems. Additionally, the need for re-verification of the patient setup for situations where couch rotations are involved was analyzed for patients treated in the cranial region. METHODS AND MATERIALS A total of 2185 initial (i.e. after pre-positioning the patient with the infrared system but before image guidance) patient setup errors (1705 in the cranial and 480 in the extracranial region) obtained by using ExacTrac (BrainLAB AG, Feldkirchen, Germany) were analyzed. Additionally, the patient setup errors as a function of the couch rotation angle were obtained by analyzing 242 setup errors in the cranial region. Before the couch was rotated, the patient setup error was corrected at couch rotation angle 0° with the aid of image guidance and the six degrees of freedom (6DoF) couch. For both situations attainment rates for two different tolerances (tolerance A: ± 0.5mm, ± 0.5°; tolerance B: ± 1.0 mm, ± 1.0°) were calculated. RESULTS The mean (± one standard deviation) initial patient setup errors for the cranial cases were -0.24 ± 1.21°, -0.23 ± 0.91° and -0.03 ± 1.07° for the pitch, roll and couch rotation axes and 0.10 ± 1.17 mm, 0.10 ± 1.62 mm and 0.11 ± 1.29 mm for the lateral, longitudinal and vertical axes, respectively. Attainment rate (all six axes simultaneously) for tolerance A was 0.6% and 13.1% for tolerance B, respectively. For the extracranial cases the corresponding values were -0.21 ± 0.95°, -0.05 ± 1.08° and -0.14 ± 1.02° for the pitch, roll and couch rotation axes and 0.15 ± 1.77 mm, 0.62 ± 1.94 mm and -0.40 ± 2.15 mm for the lateral, longitudinal and vertical axes. Attainment rate (all six axes simultaneously) for tolerance A was 0.0% and 3.1% for tolerance B, respectively. After initial setup correction and rotation of the couch to treatment position a re-correction has to be performed in 77.4% of all cases to fulfill tolerance A and in 15.6% of all cases to fulfill tolerance B. CONCLUSION The analysis of the data shows that all six axes of a 6DoF couch are used extensively for patient setup in clinical routine. In order to fulfill high patient setup accuracies (e.g. for stereotactic treatments), a 6DoF couch is recommended. Moreover, re-verification of the patient setup after rotating the couch is required in clinical routine.
Resumo:
Image-based modeling is a popular approach to perform patient-specific biomechanical simulations. Accurate modeling is critical for orthopedic application to evaluate implant design and surgical planning. It has been shown that bone strength can be estimated from the bone mineral density (BMD) and trabecular bone architecture. However, these findings cannot be directly and fully transferred to patient-specific modeling since only BMD can be derived from clinical CT. Therefore, the objective of this study was to propose a method to predict the trabecular bone structure using a µCT atlas and an image registration technique. The approach has been evaluated on femurs and patellae under physiological loading. The displacement and ultimate force for femurs loaded in stance position were predicted with an error of 2.5% and 3.7%, respectively, while predictions obtained with an isotropic material resulted in errors of 7.3% and 6.9%. Similar results were obtained for the patella, where the strain predicted using the registration approach resulted in an improved mean squared error compared to the isotropic model. We conclude that the registration of anisotropic information from of a single template bone enables more accurate patient-specific simulations from clinical image datasets than isotropic model.
Resumo:
MRSI grids frequently show spectra with poor quality, mainly because of the high sensitivity of MRS to field inhomogeneities. These poor quality spectra are prone to quantification and/or interpretation errors that can have a significant impact on the clinical use of spectroscopic data. Therefore, quality control of the spectra should always precede their clinical use. When performed manually, quality assessment of MRSI spectra is not only a tedious and time-consuming task, but is also affected by human subjectivity. Consequently, automatic, fast and reliable methods for spectral quality assessment are of utmost interest. In this article, we present a new random forest-based method for automatic quality assessment of (1) H MRSI brain spectra, which uses a new set of MRS signal features. The random forest classifier was trained on spectra from 40 MRSI grids that were classified as acceptable or non-acceptable by two expert spectroscopists. To account for the effects of intra-rater reliability, each spectrum was rated for quality three times by each rater. The automatic method classified these spectra with an area under the curve (AUC) of 0.976. Furthermore, in the subset of spectra containing only the cases that were classified every time in the same way by the spectroscopists, an AUC of 0.998 was obtained. Feature importance for the classification was also evaluated. Frequency domain skewness and kurtosis, as well as time domain signal-to-noise ratios (SNRs) in the ranges 50-75 ms and 75-100 ms, were the most important features. Given that the method is able to assess a whole MRSI grid faster than a spectroscopist (approximately 3 s versus approximately 3 min), and without loss of accuracy (agreement between classifier trained with just one session and any of the other labelling sessions, 89.88%; agreement between any two labelling sessions, 89.03%), the authors suggest its implementation in the clinical routine. The method presented in this article was implemented in jMRUI's SpectrIm plugin. Copyright © 2016 John Wiley & Sons, Ltd.
Resumo:
BACKGROUND Double-checking is widely recommended as an essential method to prevent medication errors. However, prior research has shown that the concept of double-checking is not clearly defined, and that little is known about actual practice in oncology, for example, what kind of checking procedures are applied. OBJECTIVE To study the practice of different double-checking procedures in chemotherapy administration and to explore nurses' experiences, for example, how often they actually find errors using a certain procedure. General evaluations regarding double-checking, for example, frequency of interruptions during and caused by a check, or what is regarded as its essential feature was assessed. METHODS In a cross-sectional survey, qualified nurses working in oncology departments of 3 hospitals were asked to rate 5 different scenarios of double-checking procedures regarding dimensions such as frequency of use in practice and appropriateness to prevent medication errors; they were also asked general questions about double-checking. RESULTS Overall, 274 nurses (70% response rate) participated in the survey. The procedure of jointly double-checking (read-read back) was most commonly used (69% of respondents) and rated as very appropriate to prevent medication errors. Jointly checking medication was seen as the essential characteristic of double-checking-more frequently than 'carrying out checks independently' (54% vs 24%). Most nurses (78%) found the frequency of double-checking in their department appropriate. Being interrupted in one's own current activity for supporting a double-check was reported to occur frequently. Regression analysis revealed a strong preference towards checks that are currently implemented at the responders' workplace. CONCLUSIONS Double-checking is well regarded by oncology nurses as a procedure to help prevent errors, with jointly checking being used most frequently. Our results show that the notion of independent checking needs to be transferred more actively into clinical practice. The high frequency of reported interruptions during and caused by double-checks is of concern.