124 resultados para cliche recognition

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

One to three percent of patients exposed to intravenously injected iodinated contrast media (CM) develop delayed hypersensitivity reactions. Positive patch test reactions, immunohistological findings, and CM-specific proliferation of T cells in vitro suggest a pathogenetic role for T cells. We have previously demonstrated that CM-specific T cell clones (TCCs) show a broad range of cross-reactivity to different CM. However, the mechanism of specific CM recognition by T cell receptors (TCRs) has not been analysed so far.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is conflicting evidence whether Parkinson's disease (PD) is associated with impaired recognition memory and which of its underlying processes, namely recollection and familiarity, is more affected by the disease. The present study explored the contribution of recollection and familiarity to verbal recognition memory performance in 14 nondemented PD patients and a healthy control group with two different methods: (i) the word-frequency mirror effect, and (ii) Remember/Know judgments. Overall, recognition memory of patients was intact. The word-frequency mirror effect was observed both in patients and controls: Hit rates were higher and false alarm rates were lower for low-frequency compared to high-frequency words. However, Remember/Know judgments indicated normal recollection, but impaired familiarity. Our findings suggest that mild to moderate PD patients are selectively impaired at familiarity whereas recollection and overall recognition memory are intact.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the last 10 years several molecular markers have been established as useful tools among the armamentarium of a hematologist. As a consequence, the number of performed hematologic molecular analyses has immensely increased. Often, such tests replace or complement other laboratory methods. Molecular markers can be useful in many ways: they can serve for diagnostics, describe the prognostic profile, predict which types of drugs are indicated, and can be used for the therapeutic monitoring of the patient to indicate an adequate response or predict resistance or relapse of the disease. Many markers fulfill more than one of these aspects. Most important, however, is the right choice of analyses at the right time-points!

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Supramolecular two-dimensional engineering epitomizes the design of complex molecular architectures through recognition events in multicomponent self-assembly. Despite being the subject of in-depth experimental studies, such articulated phenomena have not been yet elucidated in time and space with atomic precision. Here we use atomistic molecular dynamics to simulate the recognition of complementary hydrogen-bonding modules forming 2D porous networks on graphite. We describe the transition path from the melt to the crystalline hexagonal phase and show that self-assembly proceeds through a series of intermediate states featuring a plethora of polygonal types. Finally, we design a novel bicomponent system possessing kinetically improved self-healing ability in silico, thus demonstrating that a priori engineering of 2D self-assembly is possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mapping and ablation of atrial tachycardias (ATs) secondary to catheter ablation of atrial fibrillation (AF) is often challenging due to the complex atrial substrate, different AT mechanisms, and potential origin not only in the left atrium (LA) but also from the right atrium (RA) and the adjacent thoracic veins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemicals can elicit T-cell-mediated diseases such as allergic contact dermatitis and adverse drug reactions. Therefore, testing of chemicals, drugs and protein allergens for hazard identification and risk assessment is essential in regulatory toxicology. The seventh amendment of the EU Cosmetics Directive now prohibits the testing of cosmetic ingredients in mice, guinea pigs and other animal species to assess their sensitizing potential. In addition, the EU Chemicals Directive REACh requires the retesting of more than 30,000 chemicals for different toxicological endpoints, including sensitization, requiring vast numbers of animals. Therefore, alternative methods are urgently needed to eventually replace animal testing. Here, we summarize the outcome of an expert meeting in Rome on 7 November 2009 on the development of T-cell-based in vitro assays as tools in immunotoxicology to identify hazardous chemicals and drugs. In addition, we provide an overview of the development of the field over the last two decades.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Many medical exams use 5 options for multiple choice questions (MCQs), although the literature suggests that 3 options are optimal. Previous studies on this topic have often been based on non-medical examinations, so we sought to analyse rarely selected, 'non-functional' distractors (NF-D) in high stakes medical examinations, and their detection by item authors as well as psychometric changes resulting from a reduction in the number of options. Methods Based on Swiss Federal MCQ examinations from 2005-2007, the frequency of NF-D (selected by <1% or <5% of the candidates) was calculated. Distractors that were chosen the least or second least were identified and candidates who chose them were allocated to the remaining options using two extreme assumptions about their hypothetical behaviour: In case rarely selected distractors were eliminated, candidates could randomly choose another option - or purposively choose the correct answer, from which they had originally been distracted. In a second step, 37 experts were asked to mark the least plausible options. The consequences of a reduction from 4 to 3 or 2 distractors - based on item statistics or on the experts' ratings - with respect to difficulty, discrimination and reliability were modelled. Results About 70% of the 5-option-items had at least 1 NF-D selected by <1% of the candidates (97% for NF-Ds selected by <5%). Only a reduction to 2 distractors and assuming that candidates would switch to the correct answer in the absence of a 'non-functional' distractor led to relevant differences in reliability and difficulty (and to a lesser degree discrimination). The experts' ratings resulted in slightly greater changes compared to the statistical approach. Conclusions Based on item statistics and/or an expert panel's recommendation, the choice of a varying number of 3-4 (or partly 2) plausible distractors could be performed without marked deteriorations in psychometric characteristics.