3 resultados para breakdown point

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

70.00% 70.00%

Publicador:

Resumo:

For probability distributions on ℝq, a detailed study of the breakdown properties of some multivariate M-functionals related to Tyler's [Ann. Statist. 15 (1987) 234] ‘distribution-free’ M-functional of scatter is given. These include a symmetrized version of Tyler's M-functional of scatter, and the multivariate t M-functionals of location and scatter. It is shown that for ‘smooth’ distributions, the (contamination) breakdown point of Tyler's M-functional of scatter and of its symmetrized version are 1/q and inline image, respectively. For the multivariate t M-functional which arises from the maximum likelihood estimate for the parameters of an elliptical t distribution on ν ≥ 1 degrees of freedom the breakdown point at smooth distributions is 1/(q + ν). Breakdown points are also obtained for general distributions, including empirical distributions. Finally, the sources of breakdown are investigated. It turns out that breakdown can only be caused by contaminating distributions that are concentrated near low-dimensional subspaces.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

robreg provides a number of robust estimators for linear regression models. Among them are the high breakdown-point and high efficiency MM-estimator, the Huber and bisquare M-estimator, and the S-estimator, each supporting classic or robust standard errors. Furthermore, basic versions of the LMS/LQS (least median of squares) and LTS (least trimmed squares) estimators are provided. Note that the moremata package, also available from SSC, is required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a study on the dependence of electric breakdown discharge properties on electrode geometry and the breakdown field in liquid argon near its boiling point. The measurements were performed with a spherical cathode and a planar anode at distances ranging from 0.1 mm to 10.0 mm. A detailed study of the time evolution of the breakdown volt-ampere characteristics was performed for the first time. It revealed a slow streamer development phase in the discharge. The results of a spectroscopic study of the visible light emission of the breakdowns complement the measurements. The light emission from the initial phase of the discharge is attributed to electro-luminescence of liquid argon following a current of drifting electrons. These results contribute to set benchmarks for breakdown-safe design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).