14 resultados para bone conduction
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
The round window placement of a floating mass transducer (FMT) is a new approach for coupling an implantable hearing system to the cochlea. We evaluated the vibration transfer to the cochlear fluids of an FMT placed at the round window (rwFMT) with special attention to the role of bone conduction. A posterior tympanotomy was performed on eleven ears of seven human whole head specimens. Several rwFMT setups were examined using laser Doppler vibrometry measurements at the stapes and the promontory. In three ears, the vibrations of a bone anchored hearing aid (BAHA) and an FMT fixed to the promontory (pFMT) were compared to explore the role of bone conduction. Vibration transmission to the measuring point at the stapes was best when the rwFMT was perpendicularly placed in the round window and underlayed with connective tissue. Fixation of the rwFMT to the round window exhibited significantly lower vibration transmission. Although measurable, bone conduction from the pFMT was much lower than that of the BAHA. Our results suggest that the rwFMT does not act as a small bone anchored hearing aid, but instead, acts as a direct vibratory stimulator of the round window membrane.
Resumo:
The aim of this study was to evaluate changes in bone conduction thresholds before, during and after total stapedectomy.
Resumo:
INTRODUCTION Sound can reach the inner ear via at least two different pathways: air conduction and bone conduction (BC). BC hearing is used clinically for diagnostic purposes and for BC hearing aids. Research on the motion of the human middle ear in response to BC stimulation is typically conducted using cadaver models. We evaluated middle ear motion of Thiel-embalmed whole-head specimens in terms of linearity, reproducibility, and consistency with the reported middle ear motion of living subjects, fresh cadaveric temporal bones, and whole-heads embalmed with a Non-Thiel solution of salts. METHODS We used laser Doppler vibrometry to measure the displacement of the skull, the umbo, the cochlear promontory, the stapes, and the round window in seven ears from four human whole-head specimens embalmed according to Thiel's method. The ears were stimulated with a Baha(®) implanted behind the auricle. RESULTS The Thiel model shows promontory velocity similar to that reported in the literature for whole-heads embalmed with a Non-Thiel solution of salts (0- to 7-dB difference). The Thiel heads' relative velocity of the stapes with respect to the promontory was similar to that of fresh cadaver temporal bones (0- to 4-dB difference). The velocity of the umbo was comparable in Thiel-embalmed heads and living subjects (0- to 10-dB difference). The skull and all middle ear elements measured responded linearly to different stimulation levels, with an average difference less than 1 dB. The variability of repeated measurements for both short- (2 h; 4 dB) and long-term (4-16 weeks; 6 dB) repetitions in the same ear, and the difference between the two ears of the same donor (approximately 10 dB) were lower than the inter-individual difference (up to 25 dB). CONCLUSION Thiel-embalmed human whole-head specimens can be used as an alternative model for the study of human middle ear mechanics secondary to BC stimulation. At some frequencies, differences from living subjects must be considered.
Resumo:
OBJECTIVES To establish whether complex signal processing is beneficial for users of bone anchored hearing aids. METHODS Review and analysis of two studies from our own group, each comparing a speech processor with basic digital signal processing (either Baha Divino or Baha Intenso) and a processor with complex digital signal processing (either Baha BP100 or Baha BP110 power). The main differences between basic and complex signal processing are the number of audiologist accessible frequency channels and the availability and complexity of the directional multi-microphone noise reduction and loudness compression systems. RESULTS Both studies show a small, statistically non-significant improvement of speech understanding in quiet with the complex digital signal processing. The average improvement for speech in noise is +0.9 dB, if speech and noise are emitted both from the front of the listener. If noise is emitted from the rear and speech from the front of the listener, the advantage of the devices with complex digital signal processing as opposed to those with basic signal processing increases, on average, to +3.2 dB (range +2.3 … +5.1 dB, p ≤ 0.0032). DISCUSSION Complex digital signal processing does indeed improve speech understanding, especially in noise coming from the rear. This finding has been supported by another study, which has been published recently by a different research group. CONCLUSIONS When compared to basic digital signal processing, complex digital signal processing can increase speech understanding of users of bone anchored hearing aids. The benefit is most significant for speech understanding in noise.
Resumo:
CONCLUSION Bone conduction implants are useful in patients with conductive and mixed hearing loss for whom conventional surgery or hearing aids are no longer an option. They may also be used in patients affected by single-sided deafness. OBJECTIVES To establish a consensus on the quality standards required for centers willing to create a bone conduction implant program. METHOD To ensure a consistently high level of service and to provide patients with the best possible solution the members of the HEARRING network have established a set of quality standards for bone conduction implants. These standards constitute a realistic minimum attainable by all implant clinics and should be employed alongside current best practice guidelines. RESULTS Fifteen items are thoroughly analyzed. They include team structure, accommodation and clinical facilities, selection criteria, evaluation process, complete preoperative and surgical information, postoperative fitting and assessment, follow-up, device failure, clinical management, transfer of care and patient complaints.
Resumo:
Thiel-embalmed human whole-head specimens offer a promising alternative model for bone conduction (BC) studies of middle ear structures. In this work we present the Thiel model’s linearity and stability over time as well as its possible use in the study of a fixed ossicle chain. Using laser Doppler vibrometry (LDV), the motion of the retroauricular skull, the promontory, the stapes footplate and the round window (RW) were measured. A bone-anchored hearing aid stimulated the ears with step sinus tones logarithmically spread between 0.1 and 10 kHz. Linearity of the model was verified using input levels in steps of 10 dBV. The stability of the Thiel model over time was examined with measurements repeated after hours and weeks. The influence of a cement-fixed stapes was assessed. The middle ear elements measured responded linearly in amplitude for the applied input levels (100, 32.6, and 10 mV). The variability of measurements for both short- (2 h) and long-term (4-16 weeks) repetitions in the same ear was lower than the interindividual difference. The fixation of the stapes induced a lowered RW displacement for frequencies near 750 Hz (-4 dB) and an increased displacement for frequencies above 1 kHz (max. +3.7 dB at 4 kHz). LDV assessment of BC-induced middle ear motion in Thiel heads can be performed with stable results. The vibratory RW response is affected by the fixation of the stapes, indicating a measurable effect of ossicle chain inertia on BC response in Thiel embalmed heads.
Resumo:
This review covers the surgery for the bone-anchored hearing aid (Baha(®)). PREOPERATIVE WORKUP: A review of the indications and preoperative diagnostics shows that best results are generally obtained in patients with conductive or mixed hearing loss rehabilitation when surgery is not applicable or has failed and in patients that suffer from single-sided deafness. An audiogram must confirm that the bone conduction hearing is within the inclusion criteria. A computed tomography scan is performed in cases of malformation to assure sufficient bone thickness at the site of screw implantation.
Resumo:
OBJECTIVE: To investigate correlations between preoperative hearing thresholds and postoperative aided thresholds and speech understanding of users of Bone-anchored Hearing Aids (BAHA). Such correlations may be useful to estimate the postoperative outcome with BAHA from preoperative data. STUDY DESIGN: Retrospective case review. SETTING: Tertiary referral center. PATIENTS:: Ninety-two adult unilaterally implanted BAHA users in 3 groups: (A) 24 subjects with a unilateral conductive hearing loss, (B) 38 subjects with a bilateral conductive hearing loss, and (C) 30 subjects with single-sided deafness. INTERVENTIONS: Preoperative air-conduction and bone-conduction thresholds and 3-month postoperative aided and unaided sound-field thresholds as well as speech understanding using German 2-digit numbers and monosyllabic words were measured and analyzed. MAIN OUTCOME MEASURES: Correlation between preoperative air-conduction and bone-conduction thresholds of the better and of the poorer ear and postoperative aided thresholds as well as correlations between gain in sound-field threshold and gain in speech understanding. RESULTS: Aided postoperative sound-field thresholds correlate best with BC threshold of the better ear (correlation coefficients, r2 = 0.237 to 0.419, p = 0.0006 to 0.0064, depending on the group of subjects). Improvements in sound-field threshold correspond to improvements in speech understanding. CONCLUSION: When estimating expected postoperative aided sound-field thresholds of BAHA users from preoperative hearing thresholds, the BC threshold of the better ear should be used. For the patient groups considered, speech understanding in quiet can be estimated from the improvement in sound-field thresholds.
Resumo:
Bonebridge™ (BB) implantation relies on optimal anchoring of the bone-conduction implant in the temporal bone. Preoperative position planning has to account for the available bone thickness minimizing unwanted interference with underlying anatomical structures. This study describes the first clinical experience with a planning method based on topographic bone thickness maps (TBTM) for presigmoid BB implantations. The temporal bone was segmented enabling three-dimensional surface generation. Distances between the external and internal surface were color encoded and mapped to a TBTM. Suitable implant positions were planned with reference to the TBTM. Surgery was performed according to the standard procedure (n = 7). Computation of the TBTM and consecutive implant position planning took 70 min on average for a trained technician. Surgical time for implantations under passive TBTM image guidance was 60 min, on average. The sigmoid sinus (n = 5) and dura mater (n = 1) were exposed, as predicted with the TBTM. Feasibility of the TBTM method was shown for standard presigmoid BB implantations. The projection of three-dimensional bone thickness information into a single topographic map provides the surgeon with an intuitive display of the anatomical situation prior to implantation. Nevertheless, TBTM generation time has to be significantly reduced to simplify integration in clinical routine.
Resumo:
The level of improvement in the audiological results of Baha(®) users mainly depends on the patient's preoperative hearing thresholds and the type of Baha sound processor used. This investigation shows correlations between the preoperative hearing threshold and postoperative aided thresholds and audiological results in speech understanding in quiet of 84 Baha users with unilateral conductive hearing loss, bilateral conductive hearing loss and bilateral mixed hearing loss. Secondly, speech understanding in noise of 26 Baha users with different Baha sound processors (Compact, Divino, and BP100) is investigated. Linear regression between aided sound field thresholds and bone conduction (BC) thresholds of the better ear shows highest correlation coefficients and the steepest slope. Differences between better BC thresholds and aided sound field thresholds are smallest for mid-frequencies (1 and 2 kHz) and become larger at 0.5 and 4 kHz. For Baha users, the gain in speech recognition in quiet can be expected to lie in the order of magnitude of the gain in their hearing threshold. Compared to its predecessor sound processors Baha(®) Compact and Baha(®) Divino, Baha(®) BP100 improves speech understanding in noise significantly by +0.9 to +4.6 dB signal-to-noise ratio, depending on the setting and the use of directional microphone. For Baha users with unilateral and bilateral conductive hearing loss and bilateral mixed hearing loss, audiological results in aided sound field thresholds can be estimated with the better BC hearing threshold. The benefit in speech understanding in quiet can be expected to be similar to the gain in their sound field hearing threshold. The most recent technology of Baha sound processor improves speech understanding in noise by an order of magnitude that is well perceived by users and which can be very useful in everyday life.
Resumo:
OBJECTIVE To confirm the clinical efficacy and safety of a direct acoustic cochlear implant. STUDY DESIGN Prospective multicenter study. SETTING The study was performed at 3 university hospitals in Europe (Germany, The Netherlands, and Switzerland). PATIENTS Fifteen patients with severe-to-profound mixed hearing loss because of otosclerosis or previous failed stapes surgery. INTERVENTION Implantation with a Codacs direct acoustic cochlear implant investigational device (ID) combined with a stapedotomy with a conventional stapes prosthesis MAIN OUTCOME MEASURES Preoperative and postoperative (3 months after activation of the investigational direct acoustic cochlear implant) audiometric evaluation measuring conventional pure tone and speech audiometry, tympanometry, aided thresholds in sound field and hearing difficulty by the Abbreviated Profile of Hearing Aid Benefit questionnaire. RESULTS The preoperative and postoperative air and bone conduction thresholds did not change significantly by the implantation with the investigational Direct Acoustic Cochlear Implant. The mean sound field thresholds (0.25-8 kHz) improved significantly by 48 dB. The word recognition scores (WRS) at 50, 65, and 80 dB SPL improved significantly by 30.4%, 75%, and 78.2%, respectively, after implantation with the investigational direct acoustic cochlear implant compared with the preoperative unaided condition. The difficulty in hearing, measured by the Abbreviated Profile of Hearing Aid Benefit, decreased by 27% after implantation with the investigational direct acoustic cochlear implant. CONCLUSION Patients with moderate-to-severe mixed hearing loss because of otosclerosis can benefit substantially using the Codacs investigational device.
Resumo:
Objective. To compare hearing and speech understanding between a new, nonskin penetrating Baha system (Baha Attract) to the current Baha system using a skin-penetrating abutment. Methods. Hearing and speech understanding were measured in 16 experienced Baha users. The transmission path via the abutment was compared to a simulated Baha Attract transmission path by attaching the implantable magnet to the abutment and then by adding a sample of artificial skin and the external parts of the Baha Attract system. Four different measurements were performed: bone conduction thresholds directly through the sound processor (BC Direct), aided sound field thresholds, aided speech understanding in quiet, and aided speech understanding in noise. Results. The simulated Baha Attract transmission path introduced an attenuation starting from approximately 5 dB at 1000 Hz, increasing to 20–25 dB above 6000 Hz. However, aided sound field threshold shows smaller differences and aided speech understanding in quiet and in noise does not differ significantly between the two transmission paths. Conclusion. The Baha Attract system transmission path introduces predominately high frequency attenuation. This attenuation can be partially compensated by adequate fitting of the speech processor. No significant decrease in speech understanding in either quiet or in noise was found.
Resumo:
Bone Anchored Hearing Implants (BAHI) are routinely used in patients with conductive or mixed hearing loss, e.g. if conventional air conduction hearing aids cannot be used. New sound processors and new fitting software now allow the adjustment of parameters such as loudness compression ratios or maximum power output separately. Today it is unclear, how the choice of these parameters influences aided speech understanding in BAHI users. In this prospective experimental study, the effect of varying the compression ratio and lowering the maximum power output in a BAHI were investigated. Twelve experienced adult subjects with a mixed hearing loss participated in this study. Four different compression ratios (1.0; 1.3; 1.6; 2.0) were tested along with two different maximum power output settings, resulting in a total of eight different programs. Each participant tested each program during two weeks. A blinded Latin square design was used to minimize bias. For each of the eight programs, speech understanding in quiet and in noise was assessed. For speech in quiet, the Freiburg number test and the Freiburg monosyllabic word test at 50, 65, and 80 dB SPL were used. For speech in noise, the Oldenburg sentence test was administered. Speech understanding in quiet and in noise was improved significantly in the aided condition in any program, when compared to the unaided condition. However, no significant differences were found between any of the eight programs. In contrast, on a subjective level there was a significant preference for medium compression ratios of 1.3 to 1.6 and higher maximum power output.
Resumo:
One of the most promising applications for the restoration of small or moderately sized focal articular lesions is mosaicplasty (MP). Although recurrent hemarthrosis is a rare complication after MP, recently, various strategies have been designed to find an effective filling material to prevent postoperative bleeding from the donor site. The porous biodegradable polymer Polyactive (PA; a polyethylene glycol terephthalate - polybutylene terephthalate copolymer) represents a promising solution in this respect. A histological evaluation of the longterm PA-filled donor sites obtained from 10 experimental horses was performed. In this study, attention was primarily focused on the bone tissue developed in the plug. A computer-assisted image analysis and quantitative polarized light microscopic measurements of decalcified, longitudinally sectioned, dimethylmethylene blue (DMMB)- and picrosirius red (PS) stained sections revealed that the coverage area of the bone trabecules in the PA-filled donor tunnels was substantially (25%) enlarged compared to the neighboring cancellous bone. For this quantification, identical ROIs (regions of interest) were used and compared. The birefringence retardation values were also measured with a polarized light microscope using monochromatic light. Identical retardation values could be recorded from the bone trabeculae developed in the PA and in the neighboring bone, which indicates that the collagen orientation pattern does not differ significantly among these bone trabecules. Based on our new data, we speculate that PA promotes bone formation, and some of the currently identified degradation products of PA may enhance osteo-conduction and osteoinduction inside the donor canal.