377 resultados para bicuspid aortic valve

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Limited information exists describing the results of transcatheter aortic valve (TAV) replacement in patients with bicuspid aortic valve (BAV) disease (TAV-in-BAV). OBJECTIVES This study sought to evaluate clinical outcomes of a large cohort of patients undergoing TAV-in-BAV. METHODS We retrospectively collected baseline characteristics, procedural data, and clinical follow-up findings from 12 centers in Europe and Canada that had performed TAV-in-BAV. RESULTS A total of 139 patients underwent TAV-in-BAV with the balloon-expandable transcatheter heart valve (THV) (n = 48) or self-expandable THV (n = 91) systems. Patient mean age and Society of Thoracic Surgeons predicted risk of mortality scores were 78.0 ± 8.9 years and 4.9 ± 3.4%, respectively. BAV stenosis occurred in 65.5%, regurgitation in 0.7%, and mixed disease in 33.8% of patients. Incidence of type 0 BAV was 26.7%; type 1 BAV was 68.3%; and type 2 BAV was 5.0%. Multislice computed tomography (MSCT)-based TAV sizing was used in 63.5% of patients (77.1% balloon-expandable THV vs. 56.0% self-expandable THV, p = 0.02). Procedural mortality was 3.6%, with TAV embolization in 2.2% and conversion to surgery in 2.2%. The mean aortic gradient decreased from 48.7 ± 16.5 mm Hg to 11.4 ± 9.9 mm Hg (p < 0.0001). Post-implantation aortic regurgitation (AR) grade ≥2 occurred in 28.4% (19.6% balloon-expandable THV vs. 32.2% self-expandable THV, p = 0.11) but was prevalent in only 17.4% when MSCT-based TAV sizing was performed (16.7% balloon-expandable THV vs. 17.6% self-expandable THV, p = 0.99). MSCT sizing was associated with reduced AR on multivariate analysis (odds ratio [OR]: 0.19, 95% confidence intervals [CI]: 0.08 to 0.45; p < 0.0001). Thirty-day device safety, success, and efficacy were noted in 79.1%, 89.9%, and 84.9% of patients, respectively. One-year mortality was 17.5%. Major vascular complications were associated with increased 1-year mortality (OR: 5.66, 95% CI: 1.21 to 26.43; p = 0.03). CONCLUSIONS TAV-in-BAV is feasible with encouraging short- and intermediate-term clinical outcomes. Importantly, a high incidence of post-implantation AR is observed, which appears to be mitigated by MSCT-based TAV sizing. Given the suboptimal echocardiographic results, further study is required to evaluate long-term efficacy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES The aim of the Cavalier trial was to evaluate the safety and performance of the Perceval sutureless aortic valve in patients undergoing aortic valve replacement (AVR). We report the 30-day clinical and haemodynamic outcomes from the largest study cohort with a sutureless valve. METHODS From February 2010 to September 2013, 658 consecutive patients (mean age 77.8 years; 64.4% females; mean logistic EuroSCORE 10.2%) underwent AVR in 25 European Centres. Isolated AVRs were performed in 451 (68.5%) patients with a less invasive approach in 219 (33.3%) cases. Of the total, 40.0% were octogenarians. Congenital bicuspid aortic valve was considered an exclusion criterion. RESULTS Implantation was successful in 628 patients (95.4%). In isolated AVR through sternotomy, the mean cross-clamp time and the cardiopulmonary bypass (CPB) time were 32.6 and 53.7 min, and with the less invasive approach 38.8 and 64.5 min, respectively. The 30-day overall and valve-related mortality rates were 3.7 and 0.5%, respectively. Valve explants, stroke and endocarditis occurred in 0.6, 2.1 and in 0.1% of cases, respectively. Preoperative mean and peak pressure gradients decreased from 44.8 and 73.24 mmHg to 10.24 and 19.27 mmHg at discharge, respectively. The mean effective orifice area improved from 0.72 to 1.46 cm(2). CONCLUSIONS The current 30-day results show that the Perceval valve is safe (favourable haemodynamic effect and low complication rate), and can be implanted with a fast and reproducible technique after a short learning period. Short cross-clamp and CPB times were achieved in both isolated and combined procedures. The Perceval valve represents a promising alternative to biological AVR, especially with a less invasive approach and in older patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Whether or not there are molecular differences, at the intra- and extracellular level, between aortic dilatation in patients with bicuspid (BAV) and those with a tricuspid aortic valve (TAV) has remained controversial for years. We have performed 2-dimensional gel electrophoresis and mass spectrometry coupled with dephosphorylation and phosphostaining experiments to reveal and define protein alterations and the high abundant structural phosphoproteins in BAV compared to TAV aortic aneurysm samples. 2-D gel patterns showed a high correlation in protein expression between BAV and TAV specimens (n=10). Few proteins showed significant differences, among those a phosphorylated form of heat shock protein (HSP) 27 with significantly lower expression in BAV compared to TAV aortic samples (p=0.02). The phosphoprotein tracing revealed four different phosphoproteins including Rho GDP dissociation inhibitor 1, calponin 3, myosin regulatory light chain 2 and four differentially phosphorylated forms of HSP27. Levels of total HSP27 and dually phosphorylated HSP27 (S78/S82) were investigated in an extended patient cohort (n=15) using ELISA. Total HSP27 was significantly lower in BAV compared to TAV patients (p=0.03), with no correlation in levels of phospho-HSP27 (S78/S82) (p=0.4). Western blots analysis showed a trend towards lower levels of phospho-HSP27 (S78) in BAV patients (p=0.07). Immunohistochemical analysis revealed that differences in HSP27 occur in the cytoplasma of VSMC's and not extracellularly. Alterations in HSP27 may give early evidence for intracellular differences in aortic aneurysm of patients with BAV and TAV. Whether HSP27 and the defined phosphoproteins have a specific role in BAV associated aortic dilatation remains to be elucidated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An exponential increase in the use of transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis has been witnessed over the recent years. The current article reviews different areas of uncertainty related to patient selection. The use and limitations of risk scores are addressed, followed by an extensive discussion on the value of three-dimensional imaging for prosthesis sizing and the assessment of complex valve anatomy such as degenerated bicuspid valves. The uncertainty about valvular stenosis severity in patients with a mismatch between the transvalvular gradient and the aortic valve area, and how integrated use of echocardiography and computed tomographic imaging may help, is also addressed. Finally, patients referred for TAVI may have concomitant mitral regurgitation and/or coronary artery disease and the management of these patients is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present analysis was to identify predictors of procedural success of percutaneous transcatheter aortic valve implantation (TAVI).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors present the case of an 81-year-old patient with severe aortic stenosis who experienced left ventricular embolization of an aortic bioprosthesis during transapical aortic valve implantation. The authors discuss reasons for prosthesis embolization and reinforce the attention to technical details and the widespread use of multimodality imaging techniques. In this context, transesophageal echocardiography appears indispensable in the detection and management of procedure-related complications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Atrioventricular (AV) conduction impairment is well described after surgical aortic valve replacement, but little is known in patients undergoing transcatheter aortic valve implantation (TAVI). We assessed AV conduction and need for a permanent pacemaker in patients undergoing TAVI with the Medtronic CoreValve Revalving System (MCRS) or the Edwards Sapien Valve (ESV). Sixty-seven patients without pre-existing permanent pacemaker were included in the study. Forty-one patients (61%) and 26 patients (39%) underwent successful TAVI with the MCRS and ESV, respectively. Complete AV block occurred in 15 patients (22%), second-degree AV block in 4 (6%), and new left bundle branch block in 15 (22%), respectively. A permanent pacemaker was implanted in 23 patients (34%). Overall PR interval and QRS width increased significantly after the procedure (p <0.001 for the 2 comparisons). Implantation of the MCRS compared to the ESV resulted in a trend toward a higher rate of new left bundle branch block and complete AV block (29% vs 12%, p = 0.09 for the 2 comparisons). During follow-up, complete AV block resolved in 64% of patients. In multivariable regression analysis pre-existing right bundle branch block was the only independent predictor of complete AV block after TAVI (relative risk 7.3, 95% confidence interval 2.4 to 22.2). In conclusion, TAVI is associated with impairment of AV conduction in a considerable portion of patients, patients with pre-existing right bundle branch block are at increased risk of complete AV block, and complete AV block resolves over time in most patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Valvuloplasty of the aortic valve is currently used in selected patients for severe calcified aortic valve disease, but clinical effectiveness is low and complication rate remains high. In this study, the total particle load after valvuloplasty and the embolization risk of calcific debris into the coronary arteries was analyzed in an in vitro model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The conventional surgical aortic bioprostheses used for treatment of aortic stenosis (AS) are inherently stenotic in nature. The more favorable mechanical profile of the Medtronic CoreValve bioprosthesis may translate into a better hemodynamic and neurohormonal response.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 91-year-old female patient presented with worsening exertional dyspnea 1 month after transfemoral aortic valve implantation using an Edwards Sapien valve. She was found to have a paraprosthetic sinus of Valsalva rupture with a left-to-right shunt into the right ventricular cavity. The patient underwent coil closure of the defect with successful shunt elimination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To date, transapical aortic valve implantation has required a balloon-expandable stented valve prosthesis. More recently, a novel self-expanding sutureless stented bovine pericardial prosthesis has been developed which allows rapid aortic valve replacement via an open transaortic approach in humans. The aim of this animal study was to develop a reliable protocol to facilitate the transapical implantation of this self-expanding valve in a porcine model.