178 resultados para balloon dilatation
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Triple A syndrome is a rare autosomal recessive inherited disorder which is characterized by alacrima, adrenal insufficiency, and achalasia. We report on a 14-year old girl with dysphagia, regurgitation, and vomiting since 5 years. At the age of five years an Addison crisis was diagnosed and cortisone substitution was initiated. In addition, the patient had episodes of conjunctivitis. Severe esophagitis and candida infection were diagnosed by esophago-gastro-duodenoscopy and treated with omeprazole and fluconazole. The esophageal barium swallow was typical for achalasia. Medical treatment of achalasia with oral nifedipine resulted only in a partial and temporal improvement. But after seven balloon dilatations dysphagia and nocturnal coughing improved clearly and a remarkable gain of weight could be seen. Direct sequencing showed a homozygous nonsense mutation in exon 11 of the AAAS gene leading to truncation at position 342 of the 546 amino acid protein. CONCLUSION: Triple A syndrome has to be considered in patients with dysphagia. In our patient, the absence of tears since birth followed by adrenal insufficiency were early signs of the triple A syndrome. Balloon dilatation of the esophago-gastric junction is an effective treatment, which can avoid surgical interventions.
Resumo:
Vascular surgical training currently has to cope with various challenges, including restrictions on work hours, significant reduction of open surgical training cases in many countries, an increasing diversity of open and endovascular procedures, and distinct expectations by trainees. Even more important, patients and the public no longer accept a "learning by doing" training philosophy that leaves the learning curve on the patient's side. The Vascular International (VI) Foundation and School aims to overcome these obstacles by training conventional vascular and endovascular techniques before they are applied on patients. To achieve largely realistic training conditions, lifelike pulsatile models with exchangeable synthetic arterial inlays were created to practice carotid endarterectomy and patch plasty, open abdominal aortic aneurysm surgery, and peripheral bypass surgery, as well as for endovascular procedures, including endovascular aneurysm repair, thoracic endovascular aortic repair, peripheral balloon dilatation, and stenting. All models are equipped with a small pressure pump inside to create pulsatile flow conditions with variable peak pressures of ~90 mm Hg. The VI course schedule consists of a series of 2-hour modules teaching different open or endovascular procedures step-by-step in a standardized fashion. Trainees practice in pairs with continuous supervision and intensive advice provided by highly experienced vascular surgical trainers (trainer-to-trainee ratio is 1:4). Several evaluations of these courses show that tutor-assisted training on lifelike models in an educational-centered and motivated environment is associated with a significant increase of general and specific vascular surgical technical competence within a short period of time. Future studies should evaluate whether these benefits positively influence the future learning curve of vascular surgical trainees and clarify to what extent sophisticated models are useful to assess the level of technical skills of vascular surgical residents at national or international board examinations. This article gives an overview of our experiences of >20 years of practical training of beginners and advanced vascular surgeons using lifelike pulsatile vascular surgical training models.
Resumo:
Purpose We compared the long-term results of minimally invasive endourological intervention and open surgical revision in patients with a nonmalignant ureteroileal stricture. Materials and Methods We retrospectively evaluated the records of 74 patients (85 renal units) treated for unilateral or bilateral nonmalignant ureteroileal strictures. Overall, 96 endourological and 35 open surgical procedures were performed. Balloon dilatation and Acucise® or Ho:YAG laser endoureterotomy were used as minimally invasive endourological interventions. Open surgical revision with stricture resection and open ureteroileal end-to-side-reanastomosis was the alternate therapy. Treatment success was defined as radiological normalization or improvement of upper urinary tract morphology combined with absent flank pain, infection, ureteral stents or percutaneous nephrostomies. Results Median followup was 29 months (range 2 to 177). The overall success rate was 26% (25 of 96 cases) for endourological intervention vs 91% (32 of 35) for open surgical revision (p <0.001). Subgroup analysis showed a significant difference in the success rate of minimally invasive endourological interventions vs open surgical revision for strictures greater than 1 cm (3 of 52 cases or 6% vs 19 of 22 or 86%, p <0.001). The success rate of endourological and open surgical procedures for strictures 1 cm or less was 50% (22 of 44 cases) and 100% (13 of 13), respectively. After adjusting for multiple preoperative stricture characteristics, only stricture length was strongly and inversely associated with a successful outcome (p <0.001). Conclusions Open surgical revision produces better results than minimally invasive endourological intervention for ureteroileal strictures, particularly those greater than 1 cm. The success rate of endourological intervention is acceptable only for ureteroileal strictures 1 cm or less. Therefore, ureteroileal strictures greater than 1 cm should be primarily managed by open surgical revision.
Resumo:
OBJECTIVE: The Ross operation remains a controversially discussed procedure, because concern exists regarding late dilatation of the neoaortic root and progressive regurgitation of the autograft valve. We present our early experience with an external reinforcement of the autograft, which is inserted into a prosthetic Dacron graft with an artificial aortic root configuration. This detail should help to prevent neoaortic root dilatation. PATIENTS AND METHODS: Between 2006 and 2007, 12 patients (mean age 16 +/- 38 years; range 15-38 years) underwent a Ross procedure by this technique. Indications were aortic regurgitation (n = 2), aortic stenosis (n = 5), and combined aortic stenosis and insufficiency (n = 5). A bicuspid aortic valve was present in 9 patients. Balloon valvuloplasty had been performed in 7 patients. Follow-up was performed by clinical and echocardiographic examinations. RESULTS: No early or late deaths occurred in this small series, and freedom from reoperation is 100%. Echocardiographic follow-up confirmed absence of aortic insufficiency in 11 patients after a mean of 11 months (range 2-30 months). In 1 patient, a small asymmetric regurgitation jet was already observed at discharge echocardiography. As expected, no neoaortic root dilatation was observed during follow-up. All patients are in New York Heart Association class I. CONCLUSIONS: The present technique is a simple and reproducible technical step that does not require significant additional time. Inclusion of the autograft within a root prosthesis may be especially indicated in situations known for late autograft dilatation, namely, bicuspid aortic valve, predominant aortic insufficiency, and ascending aortic enlargement.
Resumo:
The Swiss Federal Office of Public Health demanded a nationwide health technology assessment registry for cervical and lumbar total disc arthroplasty and for balloon kyphoplasty (BKP) to make a decision about reimbursement of these interventions.
Resumo:
Endovascular treatment is an increasingly used therapeutic option in patients with chronic atherosclerotic occlusive mesenteric disease. Purpose of this study was evaluation of patency and mortality in patients treated with visceral artery percutaneous transluminal angioplasty (PTA) or stenting including follow-up.
Resumo:
Diagnostic coronary balloon occlusion (CBO) is mandatory for collateral function assessment, during angioscopy and optical coherence imaging, and when using certain coronary protection devices against emboli. Thus far, the safety of diagnostic CBO regarding procedural and long-term complications in normal coronary arteries has not been studied. In 316 patients, diagnostic CBO was performed for collateral function measurement in 426 angiographically normal vessels. The angioplasty balloon was inflated for 60 to 120 seconds using inflation pressures of 1 to 3 atm, followed by control angiography during and after CBO. Patients were divided into groups with entirely normal (n = 133) and partially normal (n = 183) vessels. Primary end points were procedural and long-term complications. De novo stenosis development was assessed by quantitative coronary angiography in 35% of the patients. Secondary end points were cardiac events at 5 years of follow-up. Procedural complications occurred in 1 patient (0.2%). In 150 repeat angiographic procedures in 92 patients (follow-up duration 10 +/- 15 months), quantitative coronary angiography revealed no difference in percentage diameter narrowing between baseline and follow-up (4.1% vs 3.9%, p = 0.69). During follow-up periods of 14 and 72 months, respectively, a new stenotic lesion was detected in 1 patient in each group (1.3%). Major cardiac events and percutaneous coronary intervention for stable angina were less frequent in the group with entirely normal than with partially normal vessels (0.8% vs 5.5%, p = 0.02, and 0.8% vs 18%, p <0.0001). In conclusion, low-inflation pressure diagnostic CBO in angiographically normal coronary arteries bears a minimal risk for procedural and long-term complications and can therefore be regarded as a safe procedure.
Resumo:
Balloon sinuplasty is a tool that is used to treat selected patients with paranasal sinus pathologies. No studies have investigated the aetiology of failed access to the frontal sinus. The aim of our study was to specify the intraoperative technical failure rate and to analyse the aetiology of the failed access to predict potential technical difficulties before surgery. We retrospectively analysed the charts of patients who underwent balloon sinuplasty from November 2007 to July 2010 at three different ENT-Centres. CT-analysis of the patients with failed access was performed. Of the 104 frontal sinuses, dilation of 12 (12%) sinuses failed. The anatomy of all failed cases revealed variations in the frontal recess (frontoethmoidal-cell, frontal-bulla-cell or agger-nasi-cell) or osteoneogenesis. In one patient, a lymphoma was overlooked during a balloon only procedure. The lymphoma was diagnosed 6 months later with a biopsy during functional endoscopic sinus surgery. In complex anatomical situations of the frontal recess, balloon sinuplasty may be challenging or impossible. In these situations, it is essential to have knowledge of classical functional endoscopic sinus surgery of the frontal recess area. The drawbacks of not including a histopathologic exam should be considered in balloon only procedures.
Resumo:
The study investigated the efficacy and safety of a balloon expandable, sirolimus-eluting stent (SES) in patients with symptomatic infrapopliteal arterial disease.
Resumo:
OBJECTIVE: To analyze myoelectric activity of the ileum, cecum, proximal loop of the ascending colon (PLAC), and spiral colon in cows with naturally occurring cecal dilatation-dislocation (CDD) and compare findings with those in healthy cows. ANIMALS: 8 CDD-affected and 6 healthy control cows. PROCEDURES: Immediately after diagnosis, CDD-affected cows underwent surgery; control cows underwent a similar surgical procedure. Before completion of surgery, 8 bipolar silver electrodes were implanted in the ileum (n = 2), cecum (1), PLAC (1), and spiral colon (4) of each cow. Beginning the day after surgery, intestinal myoelectric activity was recorded daily (8-hour period) for 4 days; data were analyzed by use of specialized software programs. Quantitative variables of myoelectric activity were compared between groups. RESULTS: Cows of both groups recovered without complications after surgery. In control cows, physiologic myoelectric activity was recorded in all intestinal segments on all days after surgery. Apparently normal myoelectric activity was evident in the ileum of CDD-affected cows on the first day after surgery, but myoelectric activity patterns in the cecum, PLAC, and spiral colon were variable with no organized cyclic myoelectric patterns, incomplete or normally organized migrating myoelectric complexes, and slow normalization over time. CONCLUSIONS AND CLINICAL RELEVANCE: After surgery for CDD, normal myoelectric patterns were disrupted in the large intestine of cows, especially in the spiral colon. Clinical recovery with effective transit of ingesta occurred before normalization of myoelectric activity in the large intestine. Therapeutic protocols for restoration or normalization of spiral colon motility should be developed for treatment of CDD-affected cattle.