33 resultados para average dip 81.5 deg
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
PURPOSE: To prospectively determine the accuracy of 1.5 Tesla (T) and 3 T magnetic resonance angiography (MRA) versus digital subtraction angiography (DSA) in the depiction of infrageniculate arteries in patients with symptomatic peripheral arterial disease. PATIENTS AND METHODS: A prospective 1.5 T, 3 T MRA, and DSA comparison was used to evaluate 360 vessel segments in 10 patients (15 limbs) with chronic symptomatic peripheral arterial disease. Selective DSA was performed within 30 days before both MRAs. The accuracy of 1.5 T and 3 T MRA was compared with DSA as the standard of reference by consensus agreement of 2 experienced readers. Signal-to-noise ratios (SNR) and signal-difference-to-noise ratios (SDNRs) were quantified. RESULTS: No significant difference in overall image quality, sufficiency for diagnosis, depiction of arterial anatomy, motion artifacts, and venous overlap was found comparing 1.5 T with 3 T MRA (P > 0.05 by Wilcoxon signed rank and as by Cohen k test). Overall sensitivity of 1.5 and 3 T MRA for detection of significant arterial stenosis was 79% and 82%, and specificity was 87% and 87% for both modalities, respectively. Interobserver agreement was excellent k > 0.8, P < 0.05) for 1.5 T as well as for 3 T MRA. SNR and SDNR were significantly increased using the 3 T system (average increase: 36.5%, P < 0.032 by t test, and 38.5%, P < 0.037 respectively). CONCLUSIONS: Despite marked improvement of SDNR, 3 T MRA does not yet provide a significantly higher accuracy in diagnostic imaging of atherosclerotic lesions below the knee joint as compared with 1.5 T MRA.
Resumo:
Surgical dislocation of the hip in the treatment of acetabular fractures allows the femoral head to be safely displaced from the acetabulum. This permits full intra-articular acetabular and femoral inspection for the evaluation and potential treatment of cartilage lesions of the labrum and femoral head, reduction of the fracture under direct vision and avoidance of intra-articular penetration with hardware. We report 60 patients with selected types of acetabular fracture who were treated using this approach. Six were lost to follow-up and the remaining 54 were available for clinical and radiological review at a mean follow-up of 4.4 years (2 to 9). Substantial damage to the intra-articular cartilage was found in the anteromedial portion of the femoral head and the posterosuperior aspect of the acetabulum. Labral lesions were predominantly seen in the posterior acetabular area. Anatomical reduction was achieved in 50 hips (93%) which was considerably higher than that seen in previous reports. There were no cases of avascular necrosis. Four patients subsequently required total hip replacement. Good or excellent results were achieved in 44 hips (81.5%). The cumulative eight-year survivorship was 89.0% (95% confidence interval 84.5 to 94.1). Significant predictors of poor outcome were involvement of the acetabular dome and lesions of the femoral cartilage greater than grade 2. The functional mid-term results were better than those of previous reports. Surgical dislocation of the hip allows accurate reduction and a predictable mid-term outcome in the management of these difficult injuries without the risk of the development of avascular necrosis.
Resumo:
Sphingosine-1-phosphate (S1P) acts as high affinity agonist at specific G-protein-coupled receptors, S1P(1-5), that play important roles e.g. in the cardiovascular and immune systems. A S1P receptor modulating drug, FTY720 (fingolimod), has been effective in phase III clinical trials for multiple sclerosis. FTY720 is a sphingosine analogue and prodrug of FTY720-phosphate, which activates all S1P receptors except S1P(2) and disrupts lymphocyte trafficking by internalizing the S1P(1) receptor. Cis-4-methylsphingosine (cis-4M-Sph) is another synthetic sphingosine analogue that is readily taken up by cells and phosphorylated to cis-4-methylsphingosine-1-phosphate (cis-4M-S1P). Therefore, we analysed whether cis-4M-Sph interacted with S1P receptors through its metabolite cis-4M-S1P in a manner similar to FTY720. Indeed, cis-4M-Sph caused an internalization of S1P receptors, but differed from FTY720 as it acted on S1P(2) and S1P(3) and only weakly on S1P(1), while FTY720 internalized S1P(1) and S1P(3) but not S1P(2). Consequently, pre-incubation with cis-4M-Sph specifically desensitized S1P-induced [Ca(2+)](i) increases, which are mediated by S1P(2) and S1P(3), in a time- and concentration-dependent manner. This effect was not shared by sphingosine or FTY720, indicating that metabolic stability and targeting of S1P(2) receptors were important. The desensitization of S1P-induced [Ca(2+)](i) increases was dependent on the expression of SphKs, predominantly of SphK2, and thus mediated by cis-4M-S1P. In agreement, cis-4M-S1P was detected in the supernatants of cells exposed to cis-4M-Sph. It is concluded that cis-4M-Sph, through its metabolite cis-4M-S1P, acts as a S1P receptor modulator and causes S1P receptor internalization and desensitization. The data furthermore help to define requirements for sphingosine kinase substrates as S1P receptor modulating prodrugs.
Resumo:
To determine the local control and complication rates for children with papillary and/or macular retinoblastoma progressing after chemotherapy and undergoing stereotactic radiotherapy (SRT) with a micromultileaf collimator.
Resumo:
Preoperative mapping of the arterial spinal supply prior to thoracoabdominal aortic aneurysm repair is highly relevant because of high risk for postoperative ischemic spinal cord injuries such as paraparesis or paraplegia.
Resumo:
Low back pain is associated with plasticity changes and central hypersensitivity in a subset of patients. We performed a case-control study to explore the discriminative ability of different quantitative sensory tests in distinguishing between 40 cases with chronic low back pain and 300 pain-free controls, and to rank these tests according to the extent of their association with chronic pain. Gender, age, height, weight, body mass index, and psychological measures were recorded as potential confounders. We used 26 quantitative sensory tests, including different modalities of pressure, heat, cold, and electrical stimulation. As measures of discrimination, we estimated receiver operating characteristics (ROC) and likelihood ratios. Six tests seemed useful (in order of their discriminative ability): (1) pressure pain detection threshold at the site of most severe pain (fitted area under the ROC, 0.87), (2) single electrical stimulation pain detection threshold (0.87), (3) single electrical stimulation reflex threshold (0.83), (4) pressure pain tolerance threshold at the site of most severe pain (0.81), (5) pressure pain detection threshold at suprascapular region (0.80), and (6) temporal summation pain threshold (0.80). Pressure and electrical pain modalities seemed most promising and may be used for diagnosis of pain hypersensitivity and potentially for identifying individuals at risk of developing chronic low back pain over time.
Resumo:
Exertional oscillatory ventilation (EOV) is an ominous prognostic sign in chronic heart failure (CHF), but little is known about the success of specific therapeutic interventions. Our aim was to study the impact of an exercise training on exercise capacity and cardiopulmonary adaptation in stable CHF patients with left ventricular systolic dysfunction and EOV. 96 stable CHF patients with EOV were included in a retrospective analysis (52 training versus 44 controls). EOV was defined as follows: 1) three or more oscillatory fluctuations in minute ventilation (V'(E)) during exercise; 2) regular oscillations; and 3) minimal average ventilation amplitude ≥5 L. EOV disappeared in 37 (71.2%) out of 52 patients after training, but only in one (2.3%) out of 44 without training (p<0.001). The decrease of EOV amplitude correlated with changes in end-tidal carbon dioxide tension (r= -0.60, p<0.001) at the respiratory compensation point and V'(E)/carbon dioxide production (V'(CO(2))) slope (r=0.50, p<0.001). Training significantly improved resting values of respiratory frequency (f(R)), V'(E), tidal volume (V(T)) and V'(E)/V'(CO(2)) ratio. During exercise, V'(E) and V(T) reached significantly higher values at the peak, while f(R) and V'(E)/V'(CO(2)) ratio were significantly lower at submaximal exercise. No change was noted in the control group. Exercise training leads to a significant decrease of EOV and improves ventilatory efficiency in patients with stable CHF.
Resumo:
We evaluated the feasibility of a modified embolization technique of pulmonary arteriovenous malformations (PAVM) using venous sac embolization with detachable coils combined with the feeding artery embolization with the Amplatzer vascular plug (AVP).
Resumo:
There is limited information regarding oral health status and other predictors of oral health-related quality of life. An association between oral health status and perceived oral health-related quality of life (OHQOL) might help clinicians motivate patients to prevent oral diseases and improve the outcome of some dental public health programs. This study evaluated the relationship between older persons' OHQOL and their functional dentition, caries, periodontal status, chronic diseases, and some demographic characteristics. A group of 733 low-income elders (mean age 72.7 [SD = 4.71, 55.6% women, 55.1% members of ethnic minority groups in the U.S. and Canada) enrolled in the TEETH clinical trial were interviewed and examined as part of their fifth annual visit for the trial. OHQOL was measured by the Geriatric Oral Health Assessment Index (GOHAI); oral health and occlusal status by clinical exams and the Eichner Index; and demographics via interviews. Elders who completed the four-year assessment had an average of 21.5 teeth (SD = 6.9), with 8.5 occluding pairs (SD = 4.6), and 32% with occlusal contacts in all four occluding zones. Stepwise multiple regressions were conducted to predict total GOHAI and its subscores (Physical, Social, and Worry). Functional dentition was a less significant predictor than ethnicity and being foreign-born. These variables, together with gender, years since immigrating, number of carious roots, and periodontal status, could predict 32% of the variance in total GOHAI, 24% in Physical, 27% in Social, and 21% in the Worry subscales. These findings suggest that functional dentition and caries influence older adults' OHQOL, but that ethnicity and immigrant status play a larger role.
Resumo:
In a suicidal gunshot fired to the chest from a carbine, the barrel of which had been shortened to half its original length, an unexpectedly large degree of destruction of the anterior thoracic wall with extensive undermining of the subcutis was found. This phenomenon was investigated for reconstructive purposes by firing test shots from two different long guns (caliber 7.92 x 57 repeating rifle with full-jacketed pointed bullet and caliber 12/70 single-barreled shotgun with shotgun slug) into blocks of soap (38 x 25 x 25 cm). The contact shots were fired before and after shortening the barrels (repeating rifle from 60 to 30 cm and single-barreled shotgun from 72 to 36 cm). The volume of the cavities in the simulant was visualized three-dimensionally with the help of a multislice computed tomography (CT) scanner and calculated sectionally. With the repeating rifle and the single-barreled shotgun, the shots from the sawed-off barrels produced significantly larger cavity diameters in the first section of the bullet track. This effect is attributable to the fact that, with a shortened barrel, the gas pressure at the muzzle is higher, thus, leading to increased expansion in the initial part of the wound track in contact shots.
Resumo:
OBJECTIVE: The standard heart-lung machine is a major trigger of systemic inflammatory response and the morbidity attributed to conventional extracorporeal circulation (CECC) is still significant. Reduction of blood-artificial surface contact and reduction of priming volume are principal aims in minimized extracorporeal circulation (MECC) cardiopulmonary bypass systems. The aim of this paper is to give an overview of the literature and to present our experience with the MECC-smart suction system. METHODS AND RESULTS: At our institution, 1799 patients underwent isolated coronary artery bypass grafting (CABG) surgery, 1372 with a MECC-smart suction system and 427 with CECC. All in-hospital data were assessed and the results were compared between the 2 groups. Patient characteristics and the distribution of EuroSCORE risk profile in our collective were similar between both groups. Average age in the MECC collective was 67.5 +/- 11.4 years and average EuroSCORE was 5.0 +/- 1.5. Average number of distal anastomoses was similar to the average number encountered in patients undergoing CABG surgery with CECC (3.3 +/- 1.0 for MECC versus 3.2 +/- 1.1 for CECC; P = ns). Myocardial protection is superior in MECC patients with lower postoperative maximal cTnI values (11.0 +/- 10.8 micromol/L for MECC versus 24.7 +/- 25.3 micromol/L for CECC; P < .05). Postoperative recovery was faster in patients operated on with the MECC-smart suction system and discharge from the hospital was earlier than for CECC patients (7.4 +/- 1.9 days for MECC versus 8.8 +/- 3.8 days for CECC; P < .05). CONCLUSIONS: The MECC-smart suction system is a safe perfusion technique for CABG surgery. In patients operated on with this system, the clinical outcome seems to be better than in patients operated on with CECC. This promising and less damaging perfusion technology has the potential to replace CECC systems in CABG surgery.
Resumo:
OBJECTIVE: To evaluate fracture patterns in bicondylar tibial plateau fractures and their impact on treatment strategy. DESIGN: Prospective data analysis with documentation of initial injury and treatment strategy, computed tomography scans, conventional x-rays, long-term evaluation of radiographs, and functional assessments. SETTING: Level 1 regional trauma center. PATIENTS: Prospective data acquisition of 14 consecutive patients (10 male and 4 female) with a bicondylar tibial plateau fracture (AO Type C). INTERVENTION: Application of a stepwise reconstruction strategy of the tibial plateau starting with the reposition and fixation of the posteromedial split fragment using a 3.5 buttress plate, followed by reposition and grafting of the lateral compartment and lateral fixation with a 3.5 plate in 90 degree to the medial fixation device. MAIN OUTCOME MEASUREMENTS: All patients were evaluated with full-length standing film, standardized x-rays, Lysholm score for functional assessment, and patient's self-appraisal. RESULTS: Most of the complex bicondylar fractures follow a regular pattern in that the medial compartment is split in a mediolateral direction with a posteromedial main fragment, combined with various amounts of multifragmental lateral compartment depression. The technique introduced allows for accurate and stable reduction and fixation of this fracture type. The final Lysholm knee score showed an average of 83.5 points (range: 64.5-92). CONCLUSIONS: Complex bicondylar tibial plateau fractures follow a regular pattern, which is not represented in existing 2-dimensional fracture classifications. A 2-incision technique starting with the reduction of the posteromedial edge results in accurate fracture reduction with low complication rates and excellent knee function.
Resumo:
Fatal falls from great height are a frequently encountered setting in forensic pathology. They present--by virtue of a calculable energy transmission to the body--an ideal model for the assessment of the effects of blunt trauma to a human body. As multislice computed tomography (MSCT) has proven not only to be invaluable in clinical examinations, but also to be a viable tool in post-mortem imaging, especially in the field of osseous injuries, we performed a MSCT scan on 20 victims of falls from great height. We hereby detected fractures and their distributions were compared with the impact energy. Our study suggests a marked increase of extensive damage to different body regions at about 20 kJ and more. The thorax was most often affected, regardless of the amount of impacting energy and the primary impact site. Cranial fracture frequency displayed a biphasic distribution with regard to the impacting energy; they were more frequent in energies of less than 10, and more than 20 kJ, but rarer in the intermediate energy group, namely that of 10-20 kJ.
Resumo:
OBJECTIVES: Various imaging techniques, including conventional radiography and computed tomography, are proposed to localize the mandibular canal prior to implant surgery. The aim of this study is to determine the incidence of altered mental nerve sensation after implant placement in the posterior segment of the mandible when a panoramic radiograph is the only preoperative imaging technique used. MATERIAL AND METHODS: The study included 1527 partially and totally edentulous patients who had consecutively received 2584 implants in the posterior segment of the mandible. Preoperative bone height was evaluated from the top of the alveolar crest to the superior border of the mandibular canal on a standard panoramic radiograph. A graduated implant scale from the implant manufacturer was used and 2 mm were subtracted as a safety margin to determine the length of the implant to be inserted. RESULTS: No permanent sensory disturbances of the inferior alveolar nerve were observed. There were two cases of postoperative paresthesia, representing 2/2584 (0.08%) of implants inserted in the posterior segment of the mandible or 2/1527 (0.13%) of patients. These sensory disturbances were minor, lasted for 3 and 6 weeks and resolved spontaneously. CONCLUSIONS: Panoramic examination can be considered a safe preoperative evaluation procedure for routine posterior mandibular implant placement. Panoramic radiography is a quick, simple, low-cost and low-dose presurgical diagnostic tool. When a safety margin of at least 2 mm above the mandibular canal is respected, panoramic radiography appears to be sufficient to evaluate available bone height prior to insertion of posterior mandibular implants; cross-sectional imaging techniques may not be necessary.