10 resultados para answers

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY DESIGN: The biomechanics of vertebral bodies augmented with real distributions of cement were investigated using nonlinear finite element (FE) analysis. OBJECTIVES: To compare stiffness, strength, and stress transfer of augmented versus nonaugmented osteoporotic vertebral bodies under compressive loading. Specifically, to examine how cement distribution, volume, and compliance affect these biomechanical variables. SUMMARY OF BACKGROUND DATA: Previous FE studies suggested that vertebroplasty might alter vertebral stress transfer, leading to adjacent vertebral failure. However, no FE study so far accounted for real cement distributions and bone damage accumulation. METHODS: Twelve vertebral bodies scanned with high-resolution pQCT and tested in compression were augmented with various volumes of cements and scanned again. Nonaugmented and augmented pQCT datasets were converted to FE models, with bone properties modeled with an elastic, plastic and damage constitutive law that was previously calibrated for the nonaugmented models. The cement-bone composite was modeled with a rule of mixture. The nonaugmented and augmented FE models were subjected to compression and their stiffness, strength, and stress map calculated for different cement compliances. RESULTS: Cement distribution dominated the stiffening and strengthening effects of augmentation. Models with cement connecting either the superior or inferior endplate (S/I fillings) were only up to 2 times stiffer than the nonaugmented models with minimal strengthening, whereas those with cement connecting both endplates (S + I fillings) were 1 to 8 times stiffer and 1 to 12 times stronger. Stress increases above and below the cement, which was higher for the S + I cases and was significantly reduced by increasing cement compliance. CONCLUSION: The developed FE approach, which accounts for real cement distributions and bone damage accumulation, provides a refined insight into the mechanics of augmented vertebral bodies. In particular, augmentation with compliant cement bridging both endplates would reduce stress transfer while providing sufficient strengthening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several new oral anticoagulants are now on the Swiss market and the general practitioner faces new challenges regarding the management of these new drugs. This consensus document aims to answer to the most frequently asked questions regarding rivaroxaban and covers different topics such as indications, initiation of treatment, drug-drug interactions and perioperative management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study focuses on relations between 7- and 9-year-old children’s and adults’ metacognitive monitoring and control processes. In addition to explicit confidence judgments (CJ), data for participants’ control behavior during learning and recall as well as implicit CJs were collected with an eye-tracking device (Tobii 1750). Results revealed developmental progression in both accuracy of implicit and explicit monitoring across age groups. In addition, efficiency of learning and recall strategies increases with age, as older participants allocate more fixation time to critical information and less time to peripheral or potentially interfering information. Correlational analyses, recall performance, metacognitive monitoring, and controlling indicate significant interrelations between all of these measures, with varying patterns of correlations within age groups. Results are discussed in regard to the intricate relationship between monitoring and recall and their relation to performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Multiple True-False-Items (MTF-Items) might offer some advantages compared to one-best-answer-questions (TypeA) as they allow more than one correct answer and may better represent clinical decisions. However, in medical education assessment MTF-Items are seldom used. Summary of Work: With this literature review existing findings on MTF-items and on TypeA were compared along the Ottawa Criteria for Good Assessment, i.e. (1) reproducibility, (2) feasibility, (3) validity, (4) acceptance, (5) educational effect, (6) catalytic effects, and (7) equivalence. We conducted a literature research on ERIC and Google Scholar including papers from the years 1935 to 2014. We used the search terms “multiple true-false”, “true-false”, “true/false”, and “Kprim” combined with “exam”, “test”, and “assessment”. Summary of Results: We included 29 out of 33 studies. Four of them were carried out in the medical field Compared to TypeA, MTF-Items are associated with (1) higher reproducibility (2) lower feasibility (3) similar validity (4) higher acceptance (5) higher educational effect (6) no studies on catalytic effects or (7) equivalence. Discussion and Conclusions: While studies show overall good characteristics of MTF items according to the Ottawa criteria, this type of question seems to be rather seldom used. One reason might be the reported lower feasibility. Overall the literature base is still weak. Furthermore, only 14 % of literature is from the medical domain. Further studies to better understand the characteristics of MTF-Items in the medical domain are warranted. Take-home messages: Overall the literature base is weak and therefore further studies are needed. Existing studies show that: MTF-Items show higher reliability, acceptance and educational effect; MTF-Items are more difficult to produce