60 resultados para anatomic fit
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Gunshot wounds (GSW) affecting the genitourinary (GU) system in civilians are uncommon. This study describes the incidence, anatomic distribution, demographics, associated injuries, management, and outcomes after civilian GU GSW.
Resumo:
The aim of this study was to demonstrate the anatomy of the quadrigeminal cistern, define the anatomic landmarks, and measure the extension of the cistern in the living by using magnetic resonance (MR) cisternography with 3-dimensional reconstruction.
Resumo:
The aims of this study were to evaluate the anatomic feasibility of medial patellofemoral ligament (MPFL) reconstruction using a part of the adductor magnus tendon and to identify possible risks.
Resumo:
The aim of this study was to assess the concomitant perioperative procedures, the causes of nasolacrimal duct obstruction, the success rate, and the complications associated with endonasal dacryocystorhinostomy (ENDCR).
Resumo:
The retromolar canal is an anatomic structure of the mandible with clinical importance. This canal branches off from the mandibular canal behind the third molar and travels to the retromolar foramen in the retromolar fossa. The retromolar canal might conduct accessory innervation to the mandibular molars or contain an aberrant buccal nerve.
Resumo:
Combined extended nerve and soft tissue defects of the upper extremity require nerve reconstruction and adequate soft tissue coverage. This study focuses on the reliability of the free vascularized sural nerve graft combined with a fasciocutaneous posterior calf flap within this indication. An anatomical study was performed on 26 cadaveric lower extremities that had been Thiel fixated and color silicone injected. Dissection of the fasciocutaneous posterior calf flap involved the medial sural nerve and superficial sural artery (SSA) with its septocutaneous perforators, extended laterally to include the lateral cutaneous branch of the sural nerve and continued to the popliteal origin of the vascular pedicle and the nerves. The vessel and nerves diameter were measured with an eyepiece reticle at 4.5× magnification. Length and diameter of the nerves and vessels were carefully assessed and reported in the dissection book. A total of 26 flaps were dissected. The SSA originated from the medial sural artery (13 cases), the popliteal artery (12 cases), or the lateral sural artery (one case). The average size of the SSA was 1.4 ± 0.4 mm. The mean pedicle length before the artery joined the sural nerve was 4.5 ± 1.9 cm. A comitant vein was present in 21 cases with an average diameter of 2.0 ± 0.8 mm, in 5 cases a separate vein needed to be dissected with an average diameter of 3.5 ± 0.4 mm. The mean medial vascularized sural nerve length was 21.2 ± 8.9 cm. Because of inclusion of the vascularized part of the lateral branch of the sural nerve (mean length of 16.7 ± 4.8 cm), a total of 35.0 ± 9.6 cm mean length of vascularized nerve could be gained from each extremity. The free vascularized sural nerve graft combined with a fasciocutaneous posterior calf flap pedicled on the SSA offers a reliable solution for complex tissue and nerve defect. Clin. Anat. 2012. © 2012 Wiley Periodicals, Inc.
Resumo:
Development of novel implants in orthopaedic trauma surgery is based on limited datasets of cadaver trials or artificial bone models. A method has been developed whereby implants can be constructed in an evidence based method founded on a large anatomic database consisting of more than 2.000 datasets of bones extracted from CT scans. The aim of this study was the development and clinical application of an anatomically pre-contoured plate for the treatment of distal fibular fractures based on the anatomical database. 48 Caucasian and Asian bone models (left and right) from the database were used for the preliminary optimization process and validation of the fibula plate. The implant was constructed to fit bilaterally in a lateral position of the fibula. Then a biomechanical comparison of the designed implant to the current gold standard in the treatment of distal fibular fractures (locking 1/3 tubular plate) was conducted. Finally, a clinical surveillance study to evaluate the grade of implant fit achieved was performed. The results showed that with a virtual anatomic database it was possible to design a fibula plate with an optimized fit for a large proportion of the population. Biomechanical testing showed the novel fibula plate to be superior to 1/3 tubular plates in 4-point bending tests. The clinical application showed a very high degree of primary implant fit. Only in a small minority of cases further intra-operative implant bending was necessary. Therefore, the goal to develop an implant for the treatment of distal fibular fractures based on the evidence of a large anatomical database could be attained. Biomechanical testing showed good results regarding the stability and the clinical application confirmed the high grade of anatomical fit.
Resumo:
OBJECTIVE: To determine the association between the 3-dimensional (3-D) motion pattern of the caudal lumbar and lumbosacral portions of the canine vertebral column and the morphology of vertebrae, facet joints, and intervertebral disks. SAMPLE POPULATION: Vertebral columns of 9 German Shepherd Dogs and 16 dogs of other breeds with similar body weights and body conditions. PROCEDURE: Different morphometric parameters of the vertebral column were assessed by computed tomography (CT) and magnetic resonance imaging. Anatomic conformation and the 3-D motion pattern were compared, and correlation coefficients were calculated. RESULTS: Total range of motion for flexion and extension was mainly associated with the facet joint angle, the facet joint angle difference between levels of the vertebral column in the transverse plane on CT images, disk height, and lever arm length. CONCLUSIONS AND CLINICAL RELEVANCE: Motion is a complex process that is influenced by the entire 3-D conformation of the lumbar portion of the vertebral column. In vivo dynamic measurements of the 3-D motion pattern of the lumbar and lumbosacral portions of the vertebral column will be necessary to further assess biomechanics that could lead to disk degeneration in dogs.