61 resultados para WAVELENGTH AUTOMATED PERIMETRY
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
AIM: To assess functional impairment in terms of visual acuity reduction and visual field defects in inactive ocular toxoplasmosis. METHODS: 61 patients with known ocular toxoplasmosis in a quiescent state were included in this prospective, cross-sectional study. A complete ophthalmic examination, retinal photodocumentation and standard automated perimetry (Octopus perimeter, program G2) were performed. Visual acuity was classified on the basis of the World Health Organization definition of visual impairment and blindness: normal (> or =20/25), mild (20/25 to 20/60), moderate (20/60 to 20/400) and severe (<20/400). Visual field damage was correspondingly graded as mild (mean defect <4 dB), moderate (mean defect 4-12 dB) or severe (mean defect >12 dB). RESULTS: 8 (13%) patients presented with bilateral ocular toxoplasmosis. Thus, a total of 69 eyes was evaluated. Visual field damage was encountered in 65 (94%) eyes, whereas only 28 (41%) eyes had reduced visual acuity, showing perimetric findings to be more sensitive in detecting chorioretinal damage (p<0.001). Correlation with the clinical localisation of chorioretinal scars was better for visual field (in 70% of the instances) than for visual acuity (33%). Moderate to severe functional impairment was registered in 65.2% for visual field, and in 27.5% for visual acuity. CONCLUSION: In its quiescent stage, ocular toxoplasmosis was associated with permanent visual field defects in >94% of the eyes studied. Hence, standard automated perimetry may better reflect the functional damage encountered by ocular toxoplasmosis than visual acuity.
Resumo:
PURPOSE To report a case of rare posterior eye manifestation of Crohn's disease preceding recurrence of inflammatory bowel disease. METHODS Case report with ophthalmoscopic findings, fluorescein/indocyanin green angiograms, automated perimetry and multifocal-ERG. RESULTS The perimetry revealed absolute and relative scotomas corresponding to multifocal inflammatory lesions in the retina and choroid, reduced a/b amplitudes in multifocal-ERG and hypofluorescent dots in angiography. Under oral prednisolone visual defects, ophthalmoscopic and angiographic findings resolved, while a/b amplitudes remained mildly reduced. The ocular changes occurred without systemic hypertension and were followed by a new episode of intestinal symptoms. CONCLUSION Multifocal inflammatory lesions in the retina and choroid in patients with Crohn's disease may occur and may precede a recurrent intestinal episode. Crohn's patients should be carefully followed up in collaboration with internal medicine specialists.
Resumo:
BACKGROUND It has been suggested that sleep apnea syndrome may play a role in normal-tension glaucoma contributing to optic nerve damage. The purpose of this study was to evaluate if optic nerve and visual field parameters in individuals with sleep apnea syndrome differ from those in controls. PATIENTS AND METHODS From the records of the sleep laboratory at the University Hospital in Bern, Switzerland, we recruited consecutive patients with severe sleep apnea syndrome proven by polysomnography, apnea-hypopnea index >20, as well as no sleep apnea controls with apnea-hypopnea index <10. Participants had to be unknown to the ophtalmology department and had to have no recent eye examination in the medical history. All participants underwent a comprehensive eye examination, scanning laser polarimetry (GDx VCC, Carl Zeiss Meditec, Dublin, California), scanning laser ophthalmoscopy (Heidelberg Retina Tomograph II, HRT II), and automated perimetry (Octopus 101 Programm G2, Haag-Streit Diagnostics, Koeniz, Switzerland). Mean values of the parameters of the two groups were compared by t-test. RESULTS The sleep apnea group consisted of 69 eyes of 35 patients; age 52.7 ± 9.7 years, apnea-hypopnea index 46.1 ± 24.8. As controls served 38 eyes of 19 patients; age 45.8 ± 11.2 years, apnea-hypopnea index 4.8 ± 1.9. A difference was found in mean intraocular pressure, although in a fully overlapping range, sleep apnea group: 15.2 ± 3.1, range 8-22 mmHg, controls: 13.6 ± 2.3, range 9-18 mmHg; p<0.01. None of the extended visual field, optic nerve head (HRT) and retinal nerve fiber layer (GDx VCC) parameters showed a significant difference between the groups. CONCLUSION Visual field, optic nerve head, and retinal nerve fiber layer parameters in patients with sleep apnea did not differ from those in the control group. Our results do not support a pathogenic relationship between sleep apnea syndrome and glaucoma.
Resumo:
Robust and accurate identification of intervertebral discs from low resolution, sparse MRI scans is essential for the automated scan planning of the MRI spine scan. This paper presents a graphical model based solution for the detection of both the positions and orientations of intervertebral discs from low resolution, sparse MRI scans. Compared with the existing graphical model based methods, the proposed method does not need a training process using training data and it also has the capability to automatically determine the number of vertebrae visible in the image. Experiments on 25 low resolution, sparse spine MRI data sets verified its performance.
Resumo:
This paper presents an automated solution for precise detection of fiducial screws from three-dimensional (3D) Computerized Tomography (CT)/Digital Volume Tomography (DVT) data for image-guided ENT surgery. Unlike previously published solutions, we regard the detection of the fiducial screws from the CT/DVT volume data as a pose estimation problem. We thus developed a model-based solution. Starting from a user-supplied initialization, our solution detects the fiducial screws by iteratively matching a computer aided design (CAD) model of the fiducial screw to features extracted from the CT/DVT data. We validated our solution on one conventional CT dataset and on five DVT volume datasets, resulting in a total detection of 24 fiducial screws. Our experimental results indicate that the proposed solution achieves much higher reproducibility and precision than the manual detection. Further comparison shows that the proposed solution produces better results on the DVT dataset than on the conventional CT dataset.
Resumo:
Vertebroplasty is a minimally invasive procedure with many benefits; however, the procedure is not without risks and potential complications, of which leakage of the cement out of the vertebral body and into the surrounding tissues is one of the most serious. Cement can leak into the spinal canal, venous system, soft tissues, lungs and intradiscal space, causing serious neurological complications, tissue necrosis or pulmonary embolism. We present a method for automatic segmentation and tracking of bone cement during vertebroplasty procedures, as a first step towards developing a warning system to avoid cement leakage outside the vertebral body. We show that by using active contours based on level sets the shape of the injected cement can be accurately detected. The model has been improved for segmentation as proposed in our previous work by including a term that restricts the level set function to the vertebral body. The method has been applied to a set of real intra-operative X-ray images and the results show that the algorithm can successfully detect different shapes with blurred and not well-defined boundaries, where the classical active contours segmentation is not applicable. The method has been positively evaluated by physicians.
Resumo:
An automated algorithm for detection of the acetabular rim was developed. Accuracy of the algorithm was validated in a sawbone study and compared against manually conducted digitization attempts, which were established as the ground truth. The latter proved to be reliable and reproducible, demonstrated by almost perfect intra- and interobserver reliability. Validation of the automated algorithm showed no significant difference compared to the manually acquired data in terms of detected version and inclination. Automated detection of the acetabular rim contour and the spatial orientation of the acetabular opening plane can be accurately achieved with this algorithm.