50 resultados para Visual Performance

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Long-term evolution of congenital toxoplasmosis is not documented. We assessed the outcome of treated congenital toxoplasmosis in a cohort of adult individuals who had undergone ante- and postnatal treatment to provide information for pediatricians and parents on the evolution of the disease. Methods: We conducted a questionnaire study on 126 adults with congenital toxoplasmosis (mean age: 22.2 years; age range: 18–31 years) monitored regularly until the time of inclusion. The main outcome measures were quality of life (Psychological General Well-Being Index) and visual function (VF14 questionnaire), and the outcomes were correlated with disease-specific factors. Results: Of the 102 patients (80.9%) who were finally included in the study, 12 (11.8%) presented neurologic effects and 60 (58.8%) manifested ocular lesions; in the latter category, 13 individuals (12.7%) had reduced visual function. The overall global quality-of-life score (74.7 ± 14.2) was close to the expected normal range for the general population (73.7 ± 15.3). Overall, visual function was only slightly impaired (M = 97.3; 95% confidence interval, 95.8–98.8). Although disease-independent critical life circumstances were associated with a reduced Psychological General Well-Being Index, this index was not influenced by any of the clinical characteristics of congenital toxoplasmosis. Neurologic pathologies, reduced visual acuity, foveal location of the retinal lesion, and squinting contributed to decreased visual function at follow-up. Conclusions: Our data reveal that treated congenital toxoplasmosis has little effect on the quality of life and visual function of the affected individuals. These encouraging findings may help to alleviate the anxiety of affected individuals and their parents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Over recent years, it has repeatedly been shown that optimal gaze strategies enhance motor control (e.g., Foulsham, 2015). However, little is known, whether, vice versa, visual performance can be improved by optimized motor control. Consequently, in two studies, we investigated visual performance as a function of motor control strategies and task parameters, respectively. In Experiment 1, 72 participants were tested on visual acuity (Landolt) and contrast sensitivity (Grating), while standing in two different postures (upright vs. squat) on a ZEPTOR-platform that vibrated at four different frequencies (0, 4, 8, 12 Hz). After each test, perceived exertion (Borg) was assessed. Significant interactions were revealed for both tests, Landolt: F(3,213)=13.25, p<.01, ηp2=.16, Grating: F(3,213)=4.27, p<.01, ηp2=.06, elucidating a larger loss of acuity/contrast sensitivity with increasing frequencies for the upright compared with the squat posture. For perceived exertion, however, a diametrical interaction for frequency was found for acuity, F(3,213)=7.45, p<.01, ηp2=.09, and contrast sensitivity, F(3,213)=7.08, p < .01, ηp2=.09, substantiating that the impaired visual performance cannot be attributed to exertion. Consequently, the squat posture could permit better head and, hence, gaze stabilization. In Experiment 2, 64 participants performed the same tests while standing in a squat position on a ski-simulator, which vibrated with two different frequencies (2.4, 3.6 Hz) and amplitudes (50, 100 mm) in a predictable or unpredictable manner. Control strategies were identified by tracking segmental motion, which allows to derive damping characteristics. Considerable main effects were found for frequency, all F’s(1,52)>10.31, all p’s<.01, all ηp2’s>.16, as well as, in the acuity test, for predictability, F(1,52)=10.31, p<.01, ηp2=.17, and by tendency for amplitude, F(1,52)=3.53, p=.06, ηp2=.06. A significant correlation between the damping amplitude in the knee joint and the performance drop in visual acuity, r=-.97, p<.001, again points towards the importance of motor control strategies to maintain optimal visual performance.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES This study examined the impact of age and magnification on the near visual acuity of dentists in their private practice under simulated clinical conditions. MATERIALS AND METHODS Miniaturized visual tests were fixed in posterior teeth of a dental phantom head and brought to 31 dentists in their respective private practice. The visual acuity of these dentists (n = 19, ≥40 years; n = 12, <40 years) was measured in a clinical setting under the following conditions: (a) natural visual acuity, distance of 300 mm; (b) natural visual acuity, free choice of the distance; and (c) loupe and additional light source, if available. RESULTS The visual acuity under the different clinical conditions varied widely between individuals. The older group of dentists had a lower median visual acuity value under all clinical conditions. This difference was highly significant for natural visual acuity at a free choice of distance (p < 0.0001). For younger dentists (<40 years), visual acuity could be significantly improved by reducing the eye-object distance (p = 0.001) or by using loupes (p = 0.008). For older dentists (≥40 years), visual acuity could be significantly improved by using loupes (p = 0.0005). CONCLUSIONS Visual performance decreased with increasing age under the specific clinical conditions of each dentist's private practice. Magnification aids can compensate for visual deficiencies. CLINICAL RELEVANCE The question of whether findings obtained under standardized conditions are valuable for the habitual setting of each dentist's private practice seems clinically relevant.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES The aims of the present study in Swiss dental practices were 1) to provide an update on the prevalence of different magnification devices, 2) to examine the relationship between self-assessed and objectively measured visual acuity, and 3) to evaluate the visual performance of dentists in the individually optimized clinical situation of their respective practices. METHODS AND MATERIALS Sixty-nine dentists from 40 randomly selected private practices (n=20, <40 years; n=49, ≥40 years) participated in the study. A questionnaire was provided to evaluate the self-assessed near visual acuity and the experience with magnification devices. The objective near visual acuity was measured under standardized conditions on a negatoscope. The clinical situation, including the use of habitual optical aids, was evaluated with visual tests on a phantom head. RESULTS A total of 64% of the dentists owned a dental loupe: 45% Galilean loupes, 16% Keplerian loupes, and 3% single lens loupes. In total, 19% of the questioned dentists owned a microscope in addition to the loupes. The correlation between the self-assessed and the objective visual performance of the dentists was weak (Spearman rank correlation coefficient=0.25). In the habitual clinical situation, magnification devices (p=0.03) and the dentist's age (p=0.0012) had a significant influence on the visual performance. CONCLUSIONS Many dentists were not aware of their visual handicaps. Optical aids such as loupes or microscopes should be used early enough to compensate for individual or age-related visual deficiencies.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE To assess the visual performance of Swiss hand surgeons in an environment similar to their workplace. The influence of Galilean (lenses only) and Keplerian loupes (lenses and prisms), the surgeon's age, and the credibility of a self-assessment of his or her own optical performance were evaluated. METHODS Sixty-three hand surgeons between 29 and 68 years of age with 70 loupes were included in the study (Galilean n = 35, Keplerian n = 35). The visual performance as surgeons was self-assessed on a modified visual analog scale and objectively measured with miniaturized visual tests in a simulated clinical setting. We evaluated the influence of the optical device by comparing Galilean and Keplerian loupes and the influence of the surgeon's age by comparing 2 subgroups: < 40 years and ≥ 40 years. RESULTS The correlation between self-assessment and objective visual performance was weak, with a Spearman rank correlation coefficient of 0.25. The near visual acuity with habitual optical aids showed considerable variability, with a range of 300% in the dimension of the smallest detected structure. The near visual acuity was significantly lower in the older group ≥ 40 years than in the younger group < 40 years with both Galilean and Keplerian loupes. Keplerian loupes allowed a significantly higher visual performance than Galilean loupes. Surgeons 40 years or older using Keplerian loupes had a similar visual acuity to surgeons younger than 40 years with Galilean loupes. CONCLUSIONS The magnified near vision of hand surgeons showed an important individual variability. Self-assessment was not a valuable instrument for surgeons to estimate their own near vision. Hand surgeons older than 40 years should use higher magnification loupes. TYPE OF STUDY/LEVEL OF EVIDENCE Diagnostic III.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The vertebrate thyroid system is important for multiple developmental processes, including eye development. Thus, its environmentally induced disruption may impact important fitness-related parameters like visual capacities and behaviour. The present study investigated the relation between molecular effects of thyroid disruption and morphological and physiological changes of eye development in zebrafish (Danio rerio). Two test compounds representing different molecular modes of thyroid disruption were used: propylthiouracil (PTU), which is an enzyme-inhibitor of thyroid hormone synthesis, and tetrabromobisphenol A (TBBPA), which interacts with the thyroid hormone receptors. Both chemicals significantly altered transcript levels of thyroid system-related genes (TRα, TRβ, TPO, TSH, DIO1, DIO2 and DIO3) in a compound-specific way. Despite these different molecular response patterns, both treatments resulted in similar pathological alterations of the eyes such as reduced size, RPE cell diameter and pigmentation, which were concentration-dependent. The morphological changes translated into impaired visual performance of the larvae: the optokinetic response was significantly and concentration-dependently decreased in both treatments, together with a significant increase of light preference of PTU-treated larvae. In addition, swimming activity was impacted. This study provides first evidence that different modes of molecular action of the thyroid disruptors can be associated with uniform apical responses. Furthermore, this study is the first to show that pathological eye development, as it can be induced by exposure to thyroid disruptors, indeed translates into impaired visual capacities of zebrafish early life stages.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this in vitro study was to compare the performance of two laser fluorescence devices (LF, LFpen), conventional visual criteria (VE), ICDAS and radiographic examination on occlusal surfaces of primary teeth. Thirty-seven primary human molars were selected from a pool of extracted teeth, which were stored frozen at -20°C until use. Teeth were assessed twice by two experienced examiners using laser fluorescence devices (LF and LFpen), conventional visual criteria, ICDAS and bitewing radiographs, with a 2-week interval between measurements. After measurement, the teeth were histologically prepared and assessed for caries extension. The highest sensitivity was observed for ICDAS at D(1) and D(3) thresholds, with no statistically significant difference when compared to the LF devices, except at the D(3) threshold. Bitewing radiographs presented the lowest values of sensitivity. Specificity at D(1) was higher for LFpen (0.90) and for VE at D(3) (0.94). When VE was combined with LFpen the post-test probabilities were the highest (94.0% and 89.2% at D(1) and D(3) thresholds, respectively). High values were observed for the combination of ICDAS and LFpen (92.0% and 80.0%, respectively). LF and LFpen showed the highest values of ICC for interexaminer reproducibility. However, regarding ICDAS, BW and VE, intraexaminer reproducibility was not the same for the two examiners. After primary visual inspection using ICDAS or not, the use of LFpen may aid in the detection of occlusal caries in primary teeth. Bitewing radiographs may be indicated only for approximal caries detection.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of the present study was to investigate whether healthy first-degree relatives of schizophrenia patients show reduced sensitivity performance, higher intra-individual variability (IIV) in reaction time (RT), and a steeper decline in sensitivity over time in a sustained attention task. Healthy first-degree relatives of schizophrenia patients (n=23) and healthy control subjects (n=46) without a family history of schizophrenia performed a demanding version of the Rapid Visual Information Processing task (RVIP). RTs, hits, false alarms, and the sensitivity index A' were assessed. The relatives were significantly less sensitive, tended to have higher IIV in RT, but sustained the impaired level of sensitivity over time. Impaired performance on the RVIP is a possible endophenotype for schizophrenia. Higher IIV in RT, apparently caused by impaired context representations, might result in fluctuations in control and lead to more frequent attentional lapses.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to compare the performance of the DIAGNOdent 2095 with visual examination for occlusal caries detection in permanent and primary molars. The sample comprised 148 permanent human molars and 179 primary human molars. The samples were measured and visually examined three times by two examiners. After measurement, the teeth were histologically prepared and assessed for caries extension. Sensitivity, specificity, accuracy and area under the receiver operating characteristics (ROC) curve were calculated. Intra-class correlation (ICC), unweighted kappa and the Bland and Altman method were used to assess inter- and intra-examiner reproducibility. DIAGNOdent showed higher specificity and lower sensitivity than did visual examination. The ICC values indicated an excellent agreement between the examinations. Kappa values varied from good to excellent for DIAGNOdent but from poor to good for visual examination. In conclusion, the DIAGNOdent may be a useful adjunct to conventional methods for occlusal caries detection.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE This study aimed to test the prediction from the Perception and Attention Deficit model of complex visual hallucinations (CVH) that impairments in visual attention and perception are key risk factors for complex hallucinations in eye disease and dementia. METHODS Two studies ran concurrently to investigate the relationship between CVH and impairments in perception (picture naming using the Graded Naming Test) and attention (Stroop task plus a novel Imagery task). The studies were in two populations-older patients with dementia (n = 28) and older people with eye disease (n = 50) with a shared control group (n = 37). The same methodology was used in both studies, and the North East Visual Hallucinations Inventory was used to identify CVH. RESULTS A reliable relationship was found for older patients with dementia between impaired perceptual and attentional performance and CVH. A reliable relationship was not found in the population of people with eye disease. CONCLUSIONS The results add to previous research that object perception and attentional deficits are associated with CVH in dementia, but that risk factors for CVH in eye disease are inconsistent, suggesting that dynamic rather than static impairments in attentional processes may be key in this population.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The present study investigated the relationship between psychometric intelligence and temporal resolution power (TRP) as simultaneously assessed by auditory and visual psychophysical timing tasks. In addition, three different theoretical models of the functional relationship between TRP and psychometric intelligence as assessed by means of the Adaptive Matrices Test (AMT) were developed. To test the validity of these models, structural equation modeling was applied. Empirical data supported a hierarchical model that assumed auditory and visual modality-specific temporal processing at a first level and amodal temporal processing at a second level. This second-order latent variable was substantially correlated with psychometric intelligence. Therefore, the relationship between psychometric intelligence and psychophysical timing performance can be explained best by a hierarchical model of temporal information processing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Patients with homonymous hemianopia have altered visual search patterns, but it is unclear how rapidly this develops and whether it reflects a strategic adaptation to altered perception or plastic changes to tissue damage. To study the temporal dynamics of adaptation alone, we used a gaze-contingent display to simulate left or right hemianopia in 10 healthy individuals as they performed 25 visual search trials. Visual search was slower and less accurate in hemianopic than in full-field viewing. With full-field viewing, there were improvements in search speed, fixation density, and number of fixations over the first 9 trials, then stable performance. With hemianopic viewing, there was a rapid shift of fixation into the blind field over the first 5-7 trials, followed by continuing gradual improvements in completion time, number of fixations, and fixation density over all 25 trials. We conclude that in the first minutes after onset of hemianopia, there is a biphasic pattern of adaptation to altered perception: an early rapid qualitative change that shifts visual search into the blind side, followed by more gradual gains in the efficiency of using this new strategy, a pattern that has parallels in other studies of motor learning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to compare the in situ and in vitro performances of a laser fluorescence (LF) device (DIAGNOdent 2095) with visual inspection for the detection of occlusal caries in permanent teeth. Sixty-four sites were selected, and visual inspection and LF assessments were carried out, in vitro, three times by two independent examiners, with a 1-week interval between evaluations. Afterwards, the occlusal surfaces were mounted on the palatal portion of removable acrylic orthodontic appliances and placed in six volunteers. Assessments were repeated and validated by histological analysis of the tooth sections under a stereomicroscope. For both examiners, the highest intra-examiner values were observed for the visual inspection when in vitro and in situ evaluations were compared. The inter-examiner reproducibility varied from 0.61 to 0.64, except for the in vitro assessment using LF, which presented a lower value (0.43). The methods showed high specificity at the D(1) threshold (considering enamel and dentin caries as disease). In vitro evaluations showed the highest values of sensitivity for both methods when compared to the in situ evaluations at D(1) and D(2) (considering only dentinal caries as the disease) thresholds. For both methods, the results of sensitivity (at D(1) and D(2)) and accuracy (at D(1)) showed significant differences between in vitro and in situ conditions. However, the sensitivity (at D(1) and D(2)), specificity and accuracy (both at D(1)) of the methods were not significantly different when the same condition was considered. It can be concluded that visual inspection and LF showed better performance in vitro than in situ.