Resumo:
OBJECTIVES: To compare the practicability, visualization of structures, and iatrogenic damage of direct and transthecal approaches to the navicular bursa for diagnostic needle endoscopy. STUDY DESIGN: Descriptive study. SAMPLE POPULATION: Equine cadaver forelimbs (n = 30). METHODS: Direct and transthecal approaches for insertion of a needle endoscope into the navicular bursa were performed. Video recordings of endoscopic procedures were assessed to determine all structures visualized within the navicular bursa. Number of attempts to gain access to the navicular bursa and total time for insertion and examination were recorded. Distribution and severity of iatrogenic lesions were assessed and scored after dissection. RESULTS: There were no statistical differences for number of attempts or time needed for insertion and examination between direct and transthecal approaches. The direct approach offered significantly increased visibility of the ipsilateral abaxial and proximal margins of the navicular bone, and ipsilateral collateral sesamoidean ligament. Iatrogenic lesions were superficial and focal, regardless of approach taken, or whether a blunt or sharp trocar tip was used. CONCLUSIONS: The direct approach provided significantly better visualization of the ipsilateral structures within the navicular bursa compared to the transthecal approach. Needle endoscopy offers a reliable technique to evaluate the navicular bursa and may complement or replace other diagnostic modalities in horses with lameness localized to the navicular region.
Resumo:
PURPOSE: To determine the reproducibility and validity of video screen measurement (VSM) of sagittal plane joint angles during gait. METHODS: 17 children with spastic cerebral palsy walked on a 10m walkway. Videos were recorded and 3d-instrumented gait analysis was performed. Two investigators measured six sagittal joint/segment angles (shank, ankle, knee, hip, pelvis, and trunk) using a custom-made software package. The intra- and interrater reproducibility were expressed by the intraclass correlation coefficient (ICC), standard error of measurements (SEM) and smallest detectable difference (SDD). The agreement between VSM and 3d joint angles was illustrated by Bland-Altman plots and limits of agreement (LoA). RESULTS: Regarding the intrarater reproducibility of VSM, the ICC ranged from 0.99 (shank) to 0.58 (trunk), the SEM from 0.81 degrees (shank) to 5.97 degrees (trunk) and the SDD from 1.80 degrees (shank) to 16.55 degrees (trunk). Regarding the interrater reproducibility, the ICC ranged from 0.99 (shank) to 0.48 (trunk), the SEM from 0.70 degrees (shank) to 6.78 degrees (trunk) and the SDD from 1.95 degrees (shank) to 18.8 degrees (trunk). The LoA between VSM and 3d data ranged from 0.4+/-13.4 degrees (knee extension stance) to 12.0+/-14.6 degrees (ankle dorsiflexion swing). CONCLUSION: When performed by the same observer, VSM mostly allows the detection of relevant changes after an intervention. However, VSM angles differ from 3d-IGA and do not reflect the real sagittal joint position, probably due to the additional movements in the other planes.
Resumo:
Accurate placement of lesions is crucial for the effectiveness and safety of a retinal laser photocoagulation treatment. Computer assistance provides the capability for improvements to treatment accuracy and execution time. The idea is to use video frames acquired from a scanning digital ophthalmoscope (SDO) to compensate for retinal motion during laser treatment. This paper presents a method for the multimodal registration of the initial frame from an SDO retinal video sequence to a retinal composite image, which may contain a treatment plan. The retinal registration procedure comprises the following steps: 1) detection of vessel centerline points and identification of the optic disc; 2) prealignment of the video frame and the composite image based on optic disc parameters; and 3) iterative matching of the detected vessel centerline points in expanding matching regions. This registration algorithm was designed for the initialization of a real-time registration procedure that registers the subsequent video frames to the composite image. The algorithm demonstrated its capability to register various pairs of SDO video frames and composite images acquired from patients.
Resumo:
Dentinal cracks are occasionally observed at the cut root face after root-end resection in apical surgery. The objective of this ex vivo study was to evaluate and compare the efficiency of visual aids to identify root-end dentinal cracks.
Resumo:
Bacterial contamination of endoscopy suites is of concern; however studies evaluating bacterial aerosols are lacking. We aimed to determine the effectiveness of air suctioning during removal of biopsy forceps in reducing bacterial air contamination.
Resumo:
In schizophrenia, nonverbal behavior, including body movement, is of theoretical and clinical importance. Although reduced nonverbal expressiveness is a major component of the negative symptoms encountered in schizophrenia, few studies have objectively assessed body movement during social interaction. In the present study, 378 brief, videotaped role-play scenes involving 27 stabilized outpatients diagnosed with paranoid-type schizophrenia were analyzed using Motion Energy Analysis (MEA). This method enables the objective measuring of body movement in conjunction with ordinary video recordings. Correlations between movement parameters (percentage of time in movement, movement speed) and symptom ratings from independent PANSS interviews were calculated. Movement parameters proved to be highly reliable. In keeping with predictions, reduced movement and movement speed correlated with negative symptoms. Accordingly, in patients who exhibited noticeable movement for less than 20% of the observation time, prominent negative symptoms were highly probable. As a control measure, the percentage of movement exhibited by the patients during role-play scenes was compared to that of their normal interactants. Patients with negative symptoms differed from normal interactants by showing significantly reduced head and body movement. Two specific positive symptoms were possibly related to movement parameters: suspiciousness tended to correlate with reduced head movement, and the expression of unusual thought content tended to relate to increased movement. Overall, a close and theoretically meaningful association between the objective movement parameters and the symptom profiles was found. MEA appears to be an objective, reliable and valid method for quantifying nonverbal behavior, an aspect which may furnish new insights into the processes related to reduced expressiveness in schizophrenia.
Resumo:
The conservative treatment of acute necrotizing pancreatitis has greatly improved due to broad antibiotic treatment and improved organ support in intensive care units. Nevertheless, infected necrosis or persistent multi-organ dysfunction are predictors of poor outcome. In these patients, there is still a need to perform necrosectomy. Open surgery results in extensive operative trauma and is associated with high morbidity and mortality. Therefore, several minimally invasive techniques have been developed recently. Retroperitoneal necrosectomy has been shown to be safe and to reduce morbidity and mortality compared to the open procedure.
Resumo:
The general guidelines on the management of ingested foreign bodies (FBs) do not address specific aspects raised by psychiatric patients, particularly in patients with borderline personality disorders (BPD) who repeatedly ingest FBs. The aim of this survey was to collect data on experience and opinions on the management of FBs in psychiatric patients with BPD and to review the relevant literature.