61 resultados para Video monitors

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: We developed a canine model of acute atopic dermatitis to evaluate the potential of compounds to treat pruritus and skin lesions induced in Dermatophagoides farinae (Df)-sensitized dogs. HYPOTHESIS/OBJECTIVES: The aim was to investigate the effectiveness of long-term recording activity monitors to assess pruritus induced by allergen challenges. ANIMALS: Thirty-two Df-sensitized laboratory dogs. METHODS: In two blinded crossover studies, 28 Df-sensitized dogs were challenged on 3 days with a Df slurry applied to clipped abdominal skin. Dogs were treated with a positive control (prednisolone 1 mg/kg once daily for 5 days, starting 1 day before challenge) or left untreated; all were fitted with activity monitors. To confirm pruritus, a parallel study with four dogs was conducted, filming the dogs before and during challenge and assessing the film for pruritic behaviour. RESULTS: The activity of dogs treated with prednisolone was significantly lower between 00.00 and 03.00 h and between 03.00 and 06.00 h compared with untreated dogs (repeated-measures ANCOVA; P < 0.0001). To determine whether the recorded night-time activity corresponded to pruritic manifestations, we compared activity monitor and video recordings of four dogs for two periods (16.30-20.30 and 24.00-03.00 h) before and during a Df challenge. The correlation between night-time activity monitor activity and observed pruritic behaviour was highly significant (test of correlation coefficient versus zero: r = 0.57, P < 0.0001). CONCLUSIONS AND CLINICAL IMPORTANCE: Determination of night-time activity with activity monitors after allergen challenge appears to be an objective and practical way to assess pruritus in this experimental model of canine atopic dermatitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the reproducibility and validity of video screen measurement (VSM) of sagittal plane joint angles during gait. METHODS: 17 children with spastic cerebral palsy walked on a 10m walkway. Videos were recorded and 3d-instrumented gait analysis was performed. Two investigators measured six sagittal joint/segment angles (shank, ankle, knee, hip, pelvis, and trunk) using a custom-made software package. The intra- and interrater reproducibility were expressed by the intraclass correlation coefficient (ICC), standard error of measurements (SEM) and smallest detectable difference (SDD). The agreement between VSM and 3d joint angles was illustrated by Bland-Altman plots and limits of agreement (LoA). RESULTS: Regarding the intrarater reproducibility of VSM, the ICC ranged from 0.99 (shank) to 0.58 (trunk), the SEM from 0.81 degrees (shank) to 5.97 degrees (trunk) and the SDD from 1.80 degrees (shank) to 16.55 degrees (trunk). Regarding the interrater reproducibility, the ICC ranged from 0.99 (shank) to 0.48 (trunk), the SEM from 0.70 degrees (shank) to 6.78 degrees (trunk) and the SDD from 1.95 degrees (shank) to 18.8 degrees (trunk). The LoA between VSM and 3d data ranged from 0.4+/-13.4 degrees (knee extension stance) to 12.0+/-14.6 degrees (ankle dorsiflexion swing). CONCLUSION: When performed by the same observer, VSM mostly allows the detection of relevant changes after an intervention. However, VSM angles differ from 3d-IGA and do not reflect the real sagittal joint position, probably due to the additional movements in the other planes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accurate placement of lesions is crucial for the effectiveness and safety of a retinal laser photocoagulation treatment. Computer assistance provides the capability for improvements to treatment accuracy and execution time. The idea is to use video frames acquired from a scanning digital ophthalmoscope (SDO) to compensate for retinal motion during laser treatment. This paper presents a method for the multimodal registration of the initial frame from an SDO retinal video sequence to a retinal composite image, which may contain a treatment plan. The retinal registration procedure comprises the following steps: 1) detection of vessel centerline points and identification of the optic disc; 2) prealignment of the video frame and the composite image based on optic disc parameters; and 3) iterative matching of the detected vessel centerline points in expanding matching regions. This registration algorithm was designed for the initialization of a real-time registration procedure that registers the subsequent video frames to the composite image. The algorithm demonstrated its capability to register various pairs of SDO video frames and composite images acquired from patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Physiologic data display is essential to decision making in critical care. Current displays echo first-generation hemodynamic monitors dating to the 1970s and have not kept pace with new insights into physiology or the needs of clinicians who must make progressively more complex decisions about their patients. The effectiveness of any redesign must be tested before deployment. Tools that compare current displays with novel presentations of processed physiologic data are required. Regenerating conventional physiologic displays from archived physiologic data is an essential first step. OBJECTIVES: The purposes of the study were to (1) describe the SSSI (single sensor single indicator) paradigm that is currently used for physiologic signal displays, (2) identify and discuss possible extensions and enhancements of the SSSI paradigm, and (3) develop a general approach and a software prototype to construct such "extended SSSI displays" from raw data. RESULTS: We present Multi Wave Animator (MWA) framework-a set of open source MATLAB (MathWorks, Inc., Natick, MA, USA) scripts aimed to create dynamic visualizations (eg, video files in AVI format) of patient vital signs recorded from bedside (intensive care unit or operating room) monitors. Multi Wave Animator creates animations in which vital signs are displayed to mimic their appearance on current bedside monitors. The source code of MWA is freely available online together with a detailed tutorial and sample data sets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arterial pressure-based cardiac output monitors (APCOs) are increasingly used as alternatives to thermodilution. Validation of these evolving technologies in high-risk surgery is still ongoing. In liver transplantation, FloTrac-Vigileo (Edwards Lifesciences) has limited correlation with thermodilution, whereas LiDCO Plus (LiDCO Ltd.) has not been tested intraoperatively. Our goal was to directly compare the 2 proprietary APCO algorithms as alternatives to pulmonary artery catheter thermodilution in orthotopic liver transplantation (OLT). The cardiac index (CI) was measured simultaneously in 20 OLT patients at prospectively defined surgical landmarks with the LiDCO Plus monitor (CI(L)) and the FloTrac-Vigileo monitor (CI(V)). LiDCO Plus was calibrated according to the manufacturer's instructions. FloTrac-Vigileo did not require calibration. The reference CI was derived from pulmonary artery catheter intermittent thermodilution (CI(TD)). CI(V)-CI(TD) bias ranged from -1.38 (95% confidence interval = -2.02 to -0.75 L/minute/m(2), P = 0.02) to -2.51 L/minute/m(2) (95% confidence interval = -3.36 to -1.65 L/minute/m(2), P < 0.001), and CI(L)-CI(TD) bias ranged from -0.65 (95% confidence interval = -1.29 to -0.01 L/minute/m(2), P = 0.047) to -1.48 L/minute/m(2) (95% confidence interval = -2.37 to -0.60 L/minute/m(2), P < 0.01). For both APCOs, bias to CI(TD) was correlated with the systemic vascular resistance index, with a stronger dependence for FloTrac-Vigileo. The capability of the APCOs for tracking changes in CI(TD) was assessed with a 4-quadrant plot for directional changes and with receiver operating characteristic curves for specificity and sensitivity. The performance of both APCOs was poor in detecting increases and fair in detecting decreases in CI(TD). In conclusion, the calibrated and uncalibrated APCOs perform differently during OLT. Although the calibrated APCO is less influenced by changes in the systemic vascular resistance, neither device can be used interchangeably with thermodilution to monitor cardiac output during liver transplantation.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In schizophrenia, nonverbal behavior, including body movement, is of theoretical and clinical importance. Although reduced nonverbal expressiveness is a major component of the negative symptoms encountered in schizophrenia, few studies have objectively assessed body movement during social interaction. In the present study, 378 brief, videotaped role-play scenes involving 27 stabilized outpatients diagnosed with paranoid-type schizophrenia were analyzed using Motion Energy Analysis (MEA). This method enables the objective measuring of body movement in conjunction with ordinary video recordings. Correlations between movement parameters (percentage of time in movement, movement speed) and symptom ratings from independent PANSS interviews were calculated. Movement parameters proved to be highly reliable. In keeping with predictions, reduced movement and movement speed correlated with negative symptoms. Accordingly, in patients who exhibited noticeable movement for less than 20% of the observation time, prominent negative symptoms were highly probable. As a control measure, the percentage of movement exhibited by the patients during role-play scenes was compared to that of their normal interactants. Patients with negative symptoms differed from normal interactants by showing significantly reduced head and body movement. Two specific positive symptoms were possibly related to movement parameters: suspiciousness tended to correlate with reduced head movement, and the expression of unusual thought content tended to relate to increased movement. Overall, a close and theoretically meaningful association between the objective movement parameters and the symptom profiles was found. MEA appears to be an objective, reliable and valid method for quantifying nonverbal behavior, an aspect which may furnish new insights into the processes related to reduced expressiveness in schizophrenia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conservative treatment of acute necrotizing pancreatitis has greatly improved due to broad antibiotic treatment and improved organ support in intensive care units. Nevertheless, infected necrosis or persistent multi-organ dysfunction are predictors of poor outcome. In these patients, there is still a need to perform necrosectomy. Open surgery results in extensive operative trauma and is associated with high morbidity and mortality. Therefore, several minimally invasive techniques have been developed recently. Retroperitoneal necrosectomy has been shown to be safe and to reduce morbidity and mortality compared to the open procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Video-laryngoscopes are marketed for intubation in difficult airway management. They provide a better view of the larynx and may facilitate tracheal intubation, but there is no adequately powered study comparing different types of video-laryngoscopes in a difficult airway scenario or in a simulated difficult airway situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For smart applications, nodes in wireless multimedia sensor networks (MWSNs) have to take decisions based on sensed scalar physical measurements. A routing protocol must provide the multimedia delivery with quality level support and be energy-efficient for large-scale networks. With this goal in mind, this paper proposes a smart Multi-hop hierarchical routing protocol for Efficient VIdeo communication (MEVI). MEVI combines an opportunistic scheme to create clusters, a cross-layer solution to select routes based on network conditions, and a smart solution to trigger multimedia transmission according to sensed data. Simulations were conducted to show the benefits of MEVI compared with the well-known Low-Energy Adaptive Clustering Hierarchy (LEACH) protocol. This paper includes an analysis of the signaling overhead, energy-efficiency, and video quality.