117 resultados para VENOUS SINUSES

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: We report the results and complications associated with standardized intraoperative management designed for the prevention of hemodynamically relevant venous air embolism during surgery performed in the semisitting position. METHODS: A protocol for preoperative evaluation and intraoperative monitoring was developed and applied in 187 consecutive patients who underwent surgery in the semisitting position between 1999 and 2004. The protocol included preoperative transesophageal echocardiography examination (TEE), intraoperative TEE monitoring, catheterization of the right atrium and a combination of fluid input, positive end expiratory pressure, and standardized positioning aiming at a positive pressure in the transverse and sigmoid sinuses. Data were collected retrospectively from the charts and intraoperative anesthesiological protocols of the patients for the incidence of clinically relevant air embolism (i.e., TEE-diagnosed air embolism plus a decrease in end tidal CO2 or hemodynamic changes) and other complications related to the semisitting position. RESULTS: Three cases (1.6%) of relevant venous air embolism occurred in 187 patients. Only 1 case (0.5%) was hemodynamically relevant, with temporary arterial blood pressure decrease and heart rate increase. Pneumatocephalus leading to lethargy was a frequent postoperative finding, which resolved spontaneously in all except 1 patient with epileptic seizure and oculomotor nerve palsy attributable to space-occupying subdurally trapped air, which had to be treated surgically. There was no permanent morbidity or mortality related to the semisitting position. CONCLUSION: Fear of massive venous air embolism is one reason for dramatic decline in the use of the semisitting position in neurosurgical practice. We found that strict adherence to a standardized protocol using TEE monitoring before and during surgery; exclusion of patients with patent foramen ovale; and a combination of positive end expiratory pressure, fluid input, and a standardized position aiming a positive pressure in the transverse and sigmoid sinuses helped to greatly minimize this complication to a rate of 0.5% for hemodynamically relevant events.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cerebrovascular diseases are significant causes of death and disability in humans. Improvements in diagnostic and therapeutic approaches strongly rely on adequate gyrencephalic, large animal models being demanded for translational research. Ovine stroke models may represent a promising approach but are currently limited by insufficient knowledge regarding the venous system of the cerebral angioarchitecture. The present study was intended to provide a comprehensive anatomical analysis of the intracranial venous system in sheep as a reliable basis for the interpretation of experimental results in such ovine models. We used corrosion casts as well as contrast-enhanced magnetic resonance venography to scrutinize blood drainage from the brain. This combined approach yielded detailed and, to some extent, novel findings. In particular, we provide evidence for chordae Willisii and lateral venous lacunae, and report on connections between the dorsal and ventral sinuses in this species. For the first time, we also describe venous confluences in the deep cerebral venous system and an 'anterior condylar confluent' as seen in humans. This report provides a detailed reference for the interpretation of venous diagnostic imaging findings in sheep, including an assessment of structure detectability by in vivo (imaging) versus ex vivo (corrosion cast) visualization methods. Moreover, it features a comprehensive interspecies-comparison of the venous cerebral angioarchitecture in man, rodents, canines and sheep as a relevant large animal model species, and describes possible implications for translational cerebrovascular research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the ease of application of two-piece, graduated, compression systems for the treatment of venous ulcers. METHODS: Four kits used to provide limb compression in the management of venous ulcers were evaluated. These have been proven to be non-inferior to various types of bandages in clinical trials. The interface pressure exerted above the ankle by the under-stocking and the complete compression system and the force required to pull the over-stocking off were assessed in vitro. Ease of application of the four kits was evaluated in four sessions by five nurses who put stockings on their own legs in a blinded manner. They expressed their assessment of the stockings using a series of visual analogue scales (VASs). RESULTS: The Sigvaris Ulcer X((R)) kit provided a mean interface pressure of 46 mmHg and required a force in the range of 60-90 N to remove it. The Mediven((R)) ulcer kit exerted the same pressure but required force in the range of 150-190 N to remove it. Two kits (SurePress((R)) Comfort and VenoTrain((R)) Ulcertec) exerted a mean pressure of only 25 mmHg and needed a force in the range of 100-160 N to remove them. Nurses judged the Ulcer X and SurePress kits easiest to apply. Application of the VenoTrain kit was found slightly more difficult. The Mediven kit was judged to be difficult to use. CONCLUSIONS: Comparison of ease of application of compression-stocking kits in normal legs revealed marked differences between them. Only one system exerted a high pressure and was easy to apply. Direct comparison of these compression kits in leg-ulcer patients is required to assess whether our laboratory findings correlate with patient compliance and ulcer healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Venous thromboembolism (VTE) prophylaxis remains underutilized, particularly in cancer patients. We explored clinical predictors of prophylaxis in hospitalized cancer patients before the onset of acute VTE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare the proportion and rate of healing, pain, and quality of life of low-strength medical compression stockings (MCS) with traditional bandages applied for the treatment of recalcitrant venous leg ulcers. METHODS: A single-center, randomized, open-label study was performed with consecutive patients. Sigvaris prototype MCS providing 15 mm Hg-25 mm Hg at the ankle were compared with multi-layer short-stretch bandages. In both groups, pads were placed above incompetent perforating veins in the ulcer area. The initial static pressure between the dressing-covered ulcer and the pad was 29 mm Hg and 49 mm Hg with MCS and bandages, respectively. Dynamic pressure measurements showed no difference. Compression was maintained day and night and changed every week. The primary endpoint was healing within 90 days. Secondary endpoints were healing within 180 days, time to healing, pain (weekly Likert scales), and monthly quality of life (ChronIc Venous Insufficiency Quality of Life [CIVIQ] questionnaire). RESULTS: Of 74 patients screened, 60 fulfilled the selection criteria and 55 completed the study; 28 in the MCS and 27 in the bandage group. Ulcers were recurrent (48%), long lasting (mean, 27 months), and large (mean, 13 cm2). All but one patient had deep venous reflux and/or incompetent perforating veins in addition to trunk varices. Characteristics of patients and ulcers were evenly distributed (exception: more edema in the MCS group; P = .019). Healing within 90 days was observed in 36% with MCS and in 48% with bandages (P = .350). Healing within 180 days was documented in 50% with MCS and in 67% with bandages (P = .210). Time to healing was identical. Pain scored 44 and 46 initially (on a scale in which 100 referred to maximum and 0 to no pain) and decreased within the first week to 20 and 28 in the MCS and bandage groups, respectively (P < .001 vs .010). Quality of life showed no difference between the treatment groups. In both groups, pain at 90 days had decreased by half, independent of completion of healing. Physical, social, and psychic impairment improved significantly in patients with healed ulcers only. CONCLUSION: Our study illustrates the difficulty of bringing large and long-standing venous ulcers to heal. The effect of compression with MCS was not different from that of compression with bandages. Both treatments alleviated pain promptly. Quality of life was improved only in patients whose ulcers had healed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The adequacy of thromboprophylaxis prescriptions in acutely ill hospitalized medical patients needs improvement. OBJECTIVE: To prospectively assess the efficacy of thromboprophylaxis adequacy of various clinical decision support systems (CDSS) with the aim of increasing the use of explicit criteria for thromboprophylaxis prescription in nine Swiss medical services. METHODS: We randomly assigned medical services to a pocket digital assistant program (PDA), pocket cards (PC) and no CDSS (controls). In centers using an electronic chart, an e-alert system (eAlerts) was developed. After 4 months, we compared post-CDSS with baseline thromboprophylaxis adequacy for the various CDSS and control groups. RESULTS: Overall, 1085 patients were included (395 controls, 196 PC, 168 PDA, 326 eAlerts), 651 pre- and 434 post-CDSS implementation: 472 (43.5%) presented a risk of VTE justifying thromboprophylaxis (31.8% pre, 61.1% post) and 556 (51.2%) received thromboprophylaxis (54.2% pre, 46.8% post). The overall adequacy (% patients with adequate prescription) of pre- and post-CDSS implementation was 56.2 and 50.7 for controls (P = 0.29), 67.3 and 45.3 for PC (P = 0.002), 66.0 and 64.9 for PDA (P = 0.99), 50.5 and 56.2 for eAlerts (P = 0.37), respectively, eAlerts limited overprescription (56% pre, 31% post, P = 0.01). CONCLUSION: While pocket cards and handhelds did not improve thromboprophylaxis adequacy, eAlerts had a modest effect, particularly on the reduction of overprescription. This effect only partially contributes to the improvement of patient safety and more work is needed towards institution-tailored tools.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obesity is a risk factor for chronic venous insufficiency and venous thromboembolism. The aim of this study was to compare venous flow parameters of the lower limbs assessed by duplex ultrasound scanning in obese and nonobese individuals according to body mass index (BMI).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Psychological distress, particularly anxiety and depression, has been associated with a prothrombotic state. However, the relationship between psychosocial factors and endogenous anticoagulants protein S (PS) and protein C (PC) has not previously been investigated. We explored the association between psychological distress, PS, and PC in patients with an objectively diagnosed venous thromboembolic event (VTE).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spontaneous dural arterio-venous fistulas can imperceptibly develop over a long time period before they suddenly develop symptoms like bruit, loss of vision, exophthalmos and conjunctival injection. We present the rare case of an occult, para-infectious, dural arterio-venous fistula which became symptomatic after endoscopic sinus surgery. Conjunctival injection and slight exophthalmos developed due to decompensation of venous drainage probably by intraoperative positioning of the patient, positive pressure ventilation and nasal packing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In patients with acute cancer-associated thrombosis, current consensus guidelines recommend anticoagulation therapy for an indefinite duration or until the cancer is resolved. Among 1,247 patients with acute venous thromboembolism (VTE) enrolled in the prospective Swiss Venous Thromboembolism Registry (SWIVTER) II from 18 hospitals, 315 (25%) had cancer of whom 179 (57%) had metastatic disease, 159 (50%) ongoing or recent chemotherapy, 83 (26%) prior cancer surgery, and 63 (20%) recurrent VTE. Long-term anticoagulation treatment for >12 months was more often planned in patients with versus without cancer (47% vs. 19%; p<0.001), with recurrent cancer-associated versus first cancer-associated VTE (70% vs. 41%; p<0.001), and with metastatic versus non-metastatic cancer (59% vs. 31%; p<0.001). In patients with cancer, recurrent VTE (OR 3.46; 95%CI 1.83-6.53), metastatic disease (OR 3.04; 95%CI 1.86-4.97), and the absence of an acute infection (OR 3.55; 95%CI 1.65-7.65) were independently associated with the intention to maintain anticoagulation for >12 months. In conclusion, long-term anticoagulation treatment for more than 12 months was planned in less than half of the cancer patients with acute VTE. The low rates of long-term anticoagulation in cancer patients with a first episode of VTE and in patients with non-metastatic cancer require particular attention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyse the cerebral venous outflow in relation to the arterial inflow during a Valsalva manoeuvre (VM). In 19 healthy volunteers (mean age 24.1 +/- 2.6 years), the middle cerebral artery (MCA) and the straight sinus (SRS) were insonated by transcranial Doppler sonography. Simultaneously the arterial blood pressure was recorded using a photoplethysmographic method. Two VM of 10 s length were performed per participant. Tracings of the variables were then transformed to equidistantly re-sampled data. Phases of the VM were analysed regarding the increase of the flow velocities and the latency to the peak. The typical four phases of the VM were also found in the SRS signal. The relative flow velocity (FV) increase was significantly higher in the SRS than in the MCA for all phases, particularly that of phase IV (p < 0.01). Comparison of the time latency of the VM phases of the MCA and SRS only showed a significant difference for phase I (p < 0.01). In particular, there was no significant difference for phase IV (15.8 +/- 0.29 vs. 16.0 +/- 0.28 s). Alterations in venous outflow in phase I are best explained by a cross-sectional change of the lumen of the SRS, while phases II and III are compatible with a Starling resistor. However, the significantly lager venous than the arterial overshoot in phase IV may be explained by the active regulation of the venous tone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To demonstrate that abdominal pressure impacts venous flow and pressure characteristics.