6 resultados para Urinary flow

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: Transsexualism occurs with an estimated prevalence of 2.4:100,000 male-to-female (MTF) and 1:100,000 female-to-male (FTM) transsexuals. As sex reassignment surgery involves surgery of the urethra and transsexuals are substituted life-long with the cross gender hormones there could possibly arise micturition disorders. Aim of the study was to determine if transsexuals have an increased risk of micturition disorders and if so which. STUDY DESIGN: Between January and July 2003 we examined 25 transsexuals whereof 18 were MTF and 7 were FTM transsexuals using King's Health Questionnaire, visual analogue scale for patient's well being, perineal and transabdominal ultrasound, urine dipstick and uroflow measurement. RESULTS: 17 out of 25 patients considered themselves very happy. In MTF transsexuals, a diverted stream, overactive bladder and stress urinary incontinence was a common problem. Prostate volume was small with 20 g and palpation did not confirm and solid or suspicious lesions. None of the patients had significant residual urine but MTF transsexuals had a reduced urinary flow. We could not detect a current urinary tract infections in any of the patients. CONCLUSION: Transsexuals have an increased risk for the development of micturition disorders including stress urinary incontinence and overactive bladder compared to age-matched control groups and should be counselled preoperatively. Reasons for the development of incontinence might be surgery including pudendal nerve damage, hormonal reasons and ageing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: We estimated the diagnostic accuracy of ultrasound detrusor thickness measurement for BOO and investigated whether this method can replace PFS for the diagnosis of BOO in some patients with lower urinary tract symptoms. MATERIALS AND METHODS: Detrusor thickness was measured by linear ultrasound (7.5 MHz) at a filling volume of greater than 50% of cystometric capacity in 102 men undergoing PFS for LUTS. All patients with prior treatment for bladder outlet obstruction and those with underlying neurological disorders were excluded from analysis. Detrusor thickness was correlated with PFS data. Obstruction was defined according to the Abrams-Griffiths nomogram. RESULTS: Detrusor thickness was significantly higher (p <0.0001) in obstructed (61 cases, median detrusor thickness 2.7 mm, IQR 2.4 to 3.3) compared to unobstructed (18 cases, median detrusor thickness 1.7 mm, IQR 1.5 to 2) as well as equivocal (23 cases, median detrusor thickness 1.8 mm, IQR 1.5 to 2.2) cases. A weak to medium Spearman correlation was found between detrusor thickness and PFS parameters. For a diagnosis of BOO, detrusor thickness of 2.9 mm or greater had a positive predictive value of 100%, a negative predictive value of 54%, specificity of 100% and sensitivity of 43%. ROC analysis revealed that detrusor thickness had a high predictive value for BOO with an AUC of 0.88 (95% CI 0.81-0.94). CONCLUSIONS: In men with LUTS without prior treatment and/or neurological disorders, ultrasonographically assessed detrusor thickness 2.9 mm or greater has a high predictive value for BOO and can replace PFS for the diagnosis of BOO. However, this cutoff value needs to be validated in a larger study population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The aim of the study was to evaluate the antiproliferative potency of Viscum album extract (VA-E) in human bladder carcinoma cell lines with regard to its possible use for intravesical therapy of superficial bladder cancer. MATERIALS AND METHODS: Proliferation (MTT-test or 3H-thymidine incorporation), necrotic disintegration (3H-thymidine release of prelabelled cells) and portions of apoptotic and/or necrotic cells (Annexin-V binding, propidium iodide (PI) labelling and DNA-fluorescence profiles by flow cytometry) were measured in four different human bladder carcinoma cell lines (T24, TCCSUP, J82 and UM-UC3) cultured in vitro. RESULTS: Antiproliferative effects of VA-E were observed in the four bladder carcinoma cell lines tested. Metabolic activity could also be completely abrogated by short-time contact of the cells with VA-E. Apoptosis and necrosis, as underlying mechanisms of action, were differentially expressed by the different cell lines. CONCLUSION: VA-E and cytotoxic proteins, i.e., mistletoe lectins (ML) and viscotoxins (VT), were able to block the growth of bladder carcinoma cells. Together with the immunomodulating properties of VA-E, the observed antiproliferative potency might give a rationale for the topical intravesical application of VA-E for the treatment of superficial bladder cancer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To assess the relationship between renal plasma flow (ERPF) or glomerular filtration rate (GFR) and the levels of norepinephrine (NE) or epinephrine (E) in plasma or urine in the presence of progressive degrees of non-oliguric renal functional impairment, these variables were assessed simultaneously in 18 normal subjects, 72 with parenchymal kidney disease and 14 with essential hypertension. ERPF and GFR were lower (P less than 0.01 to 0.001) in the groups with renal disease (mean +/- SD, 340 +/- 230 and 68 +/- 43 ml/min/1.73 m2, respectively) or essential hypertension (434 +/- 101 and 97 +/- 25 ml/min/1.73 m2) than normal subjects (597 +/- 133 and 118 +/- 14 ml/min/1.73 m2). Plasma and urinary NE and E did not differ significantly among groups and were unrelated with ERPF or GFR (range 4 to 160 ml/min/1.73 m2), except for reduced (P less than 0.001) urinary NE and E excretion in the presence of a GFR less than 20 ml/min. Subgroups with renal disease and a normal (N = 39) or high blood pressure (N = 33) also were comparable in their plasma and urinary NE and E, while ERPF and GFR tended to be lower in hypertensive patients. It is concluded that a chronic reduction in excretory kidney function may have no relevant impact on circulating levels of NE and E per se, although their urinary excretion falls distinctly at the stage of advanced renal failure. These aspects deserve consideration when pathogenetic or diagnostic studies of catecholamines are performed in normotensive or hypertensive patients with impaired kidney function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE Bladder outlet obstruction may occur after any incontinence surgery and may present as OAB, hesitancy and or the feeling of incomplete emptying. Aim of this study was to analyze the clinical and urodynamical outcome after urethrolysis in patients presenting with various clinical symptoms after Burch colposuspension for stress urinary incontinence. STUDY DESIGN Between January 2005 and December 2014, all patients who presented with symptoms and with bladder outlet obstruction were included. All patients had undergone Burch or Cowan colposuspension for stress urinary incontinence previously. Primary endpoint was the visual analogue scale (VAS) as measurement of patient perceived disease impact. Secondary endpoints were the various domains of the King's Health Questionnaire, urodynamic parameters as detrusor pressure at maximum flow, residual urine and sonographic bladder wall thickness before and six months after intervention. RESULTS Seventy-two female patients were included in this study whereof 42 suffered from urgency and urge incontinence, 20 from hesitancy and/or slow stream, seven from residual urine of more than 100ml and three from a combination of urgency and residual urine. VAS improved significantly (p<0.0001). Quality of life as determined by the King's Health Questionnaire improved for the domains general health, role limitations, emotions, physical limitations, personal limitations and incontinence impact significantly. Micturition pressure dropped significantly from 43cmH2O (95% CI 19-59cmH2O) to 18cmH2O (95% CI 16-23.5 H2O). Residual urine changed from 110ml (range 20-380ml) to 32ml (20-115ml). Bladder wall thickness decreased from 7mm (95% CI 6.235-7.152) to 5mm (95% CI 5.037-5.607; p<0.01). CONCLUSION Urethrolysis may resolve patients' symptoms and lower micturition pressure but irritative symptoms may persist.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXT Transcutaneous electrical nerve stimulation (TENS) is a promising therapy for non-neurogenic lower urinary tract dysfunction and might also be a valuable option in patients with an underlying neurological disorder. OBJECTIVE We systematically reviewed all available evidence on the efficacy and safety of TENS for treating neurogenic lower urinary tract dysfunction. EVIDENCE ACQUISITION The review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Statement. EVIDENCE SYNTHESIS After screening 1943 articles, 22 studies (two randomised controlled trials, 14 prospective cohort studies, five retrospective case series, and one case report) enrolling 450 patients were included. Eleven studies reported on acute TENS and 11 on chronic TENS. In acute TENS and chronic TENS, the mean increase of maximum cystometric capacity ranged from 69ml to 163ml and from 4ml to 156ml, the mean change of bladder volume at first detrusor overactivity from a decrease of 13ml to an increase of 175ml and from an increase of 10ml to 120ml, a mean decrease of maximum detrusor pressure at first detrusor overactivity from 18 cmH20 to 72 cmH20 and 8 cmH20, and a mean decrease of maximum storage detrusor pressure from 20 cmH20 to 58 cmH2O and from 3 cmH20 to 8 cmH2O, respectively. In chronic TENS, a mean decrease in the number of voids and leakages per 24h ranged from 1 to 3 and from 0 to 4, a mean increase of maximum flow rate from 2ml/s to 7ml/s, and a mean change of postvoid residual from an increase of 26ml to a decrease of 85ml. No TENS-related serious adverse events have been reported. Risk of bias and confounding was high in most studies. CONCLUSIONS Although preliminary data suggest TENS might be effective and safe for treating neurogenic lower urinary tract dysfunction, the evidence base is poor and more reliable data from well-designed randomised controlled trials are needed to make definitive conclusions. PATIENT SUMMARY Early data suggest that transcutaneous electrical nerve stimulation might be effective and safe for treating neurogenic lower urinary tract dysfunction, but more reliable evidence is required.