55 resultados para Unidade de Cuidados Continuados - Unity of Continuous Care

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ACCESS trial examined the 12-month effectiveness of continuous therapeutic assertive community treatment (ACT) as part of integrated care compared to standard care in a catchment area comparison design in patients with schizophrenia spectrum disorders treated with quetiapine immediate release.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Practice guidelines are systematically developed statements and recommendations that assist the physicians and patients in making decisions about appropriate health care measures for specific clinical circumstances taking into account specific national health care structures. The 1(st) revision of the S-2k guideline of the German Sepsis Society in collaboration with 17 German medical scientific societies and one self-help group provides state-of-the-art information (results of controlled clinical trials and expert knowledge) on the effective and appropriate medical care (prevention, diagnosis, therapy and follow-up care) of critically ill patients with severe sepsis or septic shock. The guideline had been developed according to the "German Instrument for Methodological Guideline Appraisal" of the Association of the Scientific Medical Societies (AWMF). In view of the inevitable advancements in scientific knowledge and technical expertise, revisions, updates and amendments must be periodically initiated. The guideline recommendations may not be applied under all circumstances. It rests with the clinician to decide whether a certain recommendation should be adopted or not, taking into consideration the unique set of clinical facts presented in connection with each individual patient as well as the available resources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study was part of a nationwide evaluation of complementary and alternative medicine (CAM) in Swiss primary care. The aim of the study was to compare patient-physician relationships and the respective patient-reported relief of symptoms between CAM and conventional primary care (COM).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Standard indicators of quality of care have been developed in the United States. Limited information exists about quality of care in countries with universal health care coverage.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background and Aims: Data on the influence of calibration on accuracy of continuous glucose monitoring (CGM) are scarce. The aim of the present study was to investigate whether the time point of calibration has an influence on sensor accuracy and whether this effect differs according to glycemic level. Subjects and Methods: Two CGM sensors were inserted simultaneously in the abdomen on either side of 20 individuals with type 1 diabetes. One sensor was calibrated predominantly using preprandial glucose (calibration(PRE)). The other sensor was calibrated predominantly using postprandial glucose (calibration(POST)). At minimum three additional glucose values per day were obtained for analysis of accuracy. Sensor readings were divided into four categories according to the glycemic range of the reference values (low, ≤4 mmol/L; euglycemic, 4.1-7 mmol/L; hyperglycemic I, 7.1-14 mmol/L; and hyperglycemic II, >14 mmol/L). Results: The overall mean±SEM absolute relative difference (MARD) between capillary reference values and sensor readings was 18.3±0.8% for calibration(PRE) and 21.9±1.2% for calibration(POST) (P<0.001). MARD according to glycemic range was 47.4±6.5% (low), 17.4±1.3% (euglycemic), 15.0±0.8% (hyperglycemic I), and 17.7±1.9% (hyperglycemic II) for calibration(PRE) and 67.5±9.5% (low), 24.2±1.8% (euglycemic), 15.5±0.9% (hyperglycemic I), and 15.3±1.9% (hyperglycemic II) for calibration(POST). In the low and euglycemic ranges MARD was significantly lower in calibration(PRE) compared with calibration(POST) (P=0.007 and P<0.001, respectively). Conclusions: Sensor calibration predominantly based on preprandial glucose resulted in a significantly higher overall sensor accuracy compared with a predominantly postprandial calibration. The difference was most pronounced in the hypo- and euglycemic reference range, whereas both calibration patterns were comparable in the hyperglycemic range.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Swiss health care is relatively costly. In order better to understand the drivers of spending, this study analyses geographic variation in per capita consultation costs for ambulatory care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For continuous outcomes measured using instruments with an established minimally important difference (MID), pooled estimates can be usefully reported in MID units. Approaches suggested thus far omit studies that used instruments without an established MID. We describe an approach that addresses this limitation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To compare the 1-year cost-effectiveness of therapeutic assertive community treatment (ACT) with standard care in schizophrenia. ACT was specifically developed for patients with schizophrenia, delivered by psychosis experts highly trained in respective psychotherapies, and embedded into an integrated care system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was initiated to assess the quantitative impact of patient anthropometrics and dihydropyrimidine dehydrogenase (DPYD) mutations on the pharmacokinetics (PK) of 5-fluorouracil (5FU) and to explore limited sampling strategies of 5FU.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Obstructive sleep apnea (OSA) has been associated with an increased risk of atherothrombotic events. A prothrombotic state might partially explain this link. This study investigated OSA patients' day/night rhythm of several prothrombotic markers and their potential changes with therapeutic continuous positive airway pressure (CPAP).

Relevância:

100.00% 100.00%

Publicador: