11 resultados para Underwater robotics

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The three main classes of robotics in ear, nose and throat (ENT) surgery (telemanipulation, image-guided functional servoing, and computer numerical control) are discussed and important examples of applications are described to show both technological and clinical developments. As access to many anatomical features of the head requires very small and compact tools to accurately perform procedures, examples are give in ear surgery where manipulation of the minute ossicles requires fine, dexterous movements.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computer-aided microscopic surgery of the lateral skull base is a rare intervention in daily practice. It is often a delicate and difficult minimally invasive intervention, since orientation between the petrous bone and the petrous bone apex is often challenging. In the case of aural atresia or tumors the normal anatomical landmarks are often absent, making orientation more difficult. Navigation support, together with imaging techniques such as CT, MR and angiography, enable the surgeon in such cases to perform the operation more accurately and, in some cases, also in a shorter time. However, there are no internationally standardised indications for navigated surgery on the lateral skull base. Miniaturised robotic systems are still in the initial validation phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Robotics-assisted tilt table technology was introduced for early rehabilitation of neurological patients. It provides cyclical stepping movement and physiological loading of the legs. The aim of the present study was to assess the feasibility of this type of device for peak cardiopulmonary performance testing using able-bodied subjects. METHODS: A robotics-assisted tilt table was augmented with force sensors in the thigh cuffs and a work rate estimation algorithm. A custom visual feedback system was employed to guide the subjects' work rate and to provide real time feedback of actual work rate. Feasibility assessment focused on: (i) implementation (technical feasibility), and (ii) responsiveness (was there a measurable, high-level cardiopulmonary reaction?). For responsiveness testing, each subject carried out an incremental exercise test to the limit of functional capacity with a work rate increment of 5 W/min in female subjects and 8 W/min in males. RESULTS: 11 able-bodied subjects were included (9 male, 2 female; age 29.6 ± 7.1 years: mean ± SD). Resting oxygen uptake (O_{2}) was 4.6 ± 0.7 mL/min/kg and O_{2}peak was 32.4 ± 5.1 mL/min/kg; this mean O_{2}peak was 81.1% of the predicted peak value for cycle ergometry. Peak heart rate (HRpeak) was 177.5 ± 9.7 beats/min; all subjects reached at least 85% of their predicted HRpeak value. Respiratory exchange ratio (RER) at O_{2}peak was 1.02 ± 0.07. Peak work rate) was 61.3 ± 15.1 W. All subjects reported a Borg CR10 value for exertion and leg fatigue of 7 or more. CONCLUSIONS: The robotics-assisted tilt table is deemed feasible for peak cardiopulmonary performance testing: the approach was found to be technically implementable and substantial cardiopulmonary responses were observed. Further testing in neurologically-impaired subjects is warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Robotics-assisted tilt table (RATT) technology provides body support, cyclical stepping movement and physiological loading. This technology can potentially be used to facilitate the estimation of peak cardiopulmonary performance parameters in patients who have neurological or other problems that may preclude testing on a treadmill or cycle ergometer. The aim of the study was to compare the magnitude of peak cardiopulmonary performance parameters including peak oxygen uptake (VO2peak) and peak heart rate (HRpeak) obtained from a robotics-assisted tilt table (RATT), a cycle ergometer and a treadmill. The strength of correlations between the three devices, test-retest reliability and repeatability were also assessed. Eighteen healthy subjects performed six maximal exercise tests, with two tests on each of the three exercise modalities. Data from the second tests were used for the comparative and correlation analyses. For nine subjects, test-retest reliability and repeatability of VO2peak and HRpeak were assessed. Absolute VO2peak from the RATT, the cycle ergometer and the treadmill was (mean (SD)) 2.2 (0.56), 2.8 (0.80) and 3.2 (0.87) L/min, respectively (p < 0.001). HRpeak from the RATT, the cycle ergometer and the treadmill was 168 (9.5), 179 (7.9) and 184 (6.9) beats/min, respectively (p < 0.001). VO2peak and HRpeak from the RATT vs the cycle ergometer and the RATT vs the treadmill showed strong correlations. Test-retest reliability and repeatability were high for VO2peak and HRpeak for all devices. The results demonstrate that the RATT is a valid and reliable device for exercise testing. There is potential for the RATT to be used in severely impaired subjects who cannot use the standard modalities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: We evaluated the feasibility of an augmented robotics-assisted tilt table (RATT) for incremental cardiopulmonary exercise testing (CPET) and exercise training in dependent-ambulatory stroke patients. METHODS: Stroke patients (Functional Ambulation Category ≤ 3) underwent familiarization, an incremental exercise test (IET) and a constant load test (CLT) on separate days. A RATT equipped with force sensors in the thigh cuffs, a work rate estimation algorithm and real-time visual feedback to guide the exercise work rate was used. Feasibility assessment considered technical feasibility, patient tolerability, and cardiopulmonary responsiveness. RESULTS: Eight patients (4 female) aged 58.3 ± 9.2 years (mean ± SD) were recruited and all completed the study. For IETs, peak oxygen uptake (V'O2peak), peak heart rate (HRpeak) and peak work rate (WRpeak) were 11.9 ± 4.0 ml/kg/min (45 % of predicted V'O2max), 117 ± 32 beats/min (72 % of predicted HRmax) and 22.5 ± 13.0 W, respectively. Peak ratings of perceived exertion (RPE) were on the range "hard" to "very hard". All 8 patients reached their limit of functional capacity in terms of either their cardiopulmonary or neuromuscular performance. A ventilatory threshold (VT) was identified in 7 patients and a respiratory compensation point (RCP) in 6 patients: mean V'O2 at VT and RCP was 8.9 and 10.7 ml/kg/min, respectively, which represent 75 % (VT) and 85 % (RCP) of mean V'O2peak. Incremental CPET provided sufficient information to satisfy the responsiveness criteria and identification of key outcomes in all 8 patients. For CLTs, mean steady-state V'O2 was 6.9 ml/kg/min (49 % of V'O2 reserve), mean HR was 90 beats/min (56 % of HRmax), RPEs were > 2, and all patients maintained the active work rate for 10 min: these values meet recommended intensity levels for bouts of training. CONCLUSIONS: The augmented RATT is deemed feasible for incremental cardiopulmonary exercise testing and exercise training in dependent-ambulatory stroke patients: the approach was found to be technically implementable, acceptable to the patients, and it showed substantial cardiopulmonary responsiveness. This work has clinical implications for patients with severe disability who otherwise are not able to be tested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The robotics-assisted tilt table (RATT), including actuators for tilting and cyclical leg movement, is used for rehabilitation of severely disabled neurological patients. Following further engineering development of the system, i.e. the addition of force sensors and visual bio-feedback, patients can actively participate in exercise testing and training on the device. Peak cardiopulmonary performance parameters were previously investigated, but it also important to compare submaximal parameters with standard devices. The aim of this study was to evaluate the feasibility of the RATT for estimation of submaximal exercise thresholds by comparison with a cycle ergometer and a treadmill. METHODS: 17 healthy subjects randomly performed six maximal individualized incremental exercise tests, with two tests on each of the three exercise modalities. The ventilatory anaerobic threshold (VAT) and respiratory compensation point (RCP) were determined from breath-by-breath data. RESULTS: VAT and RCP on the RATT were lower than the cycle ergometer and the treadmill: oxygen uptake (V'O2) at VAT was [mean (SD)] 1.2 (0.3), 1.5 (0.4) and 1.6 (0.5) L/min, respectively (p < 0.001); V'O2 at RCP was 1.7 (0.4), 2.3 (0.8) and 2.6 (0.9) L/min, respectively (p = 0.001). High correlations for VAT and RCP were found between the RATT vs the cycle ergometer and RATT vs the treadmill (R on the range 0.69-0.80). VAT and RCP demonstrated excellent test-retest reliability for all three devices (ICC from 0.81 to 0.98). Mean differences between the test and retest values on each device were close to zero. The ventilatory equivalent for O2 at VAT for the RATT and cycle ergometer were similar and both were higher than the treadmill. The ventilatory equivalent for CO2 at RCP was similar for all devices. Ventilatory equivalent parameters demonstrated fair-to-excellent reliability and repeatability. CONCLUSIONS: It is feasible to use the RATT for estimation of submaximal exercise thresholds: VAT and RCP on the RATT were lower than the cycle ergometer and the treadmill, but there were high correlations between the RATT vs the cycle ergometer and vs the treadmill. Repeatability and test-retest reliability of all submaximal threshold parameters from the RATT were comparable to those of standard devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the lack of exercise testing devices that can be employed in stroke patients with severe disability, the aim of this PhD research was to investigate the clinical feasibility of using a robotics-assisted tilt table (RATT) as a method for cardiopulmonary exercise testing (CPET) and exercise training in stroke patients. For this purpose, the RATT was augmented with force sensors, a visual feedback system and a work rate calculation algorithm. As the RATT had not been used previously for CPET, the first phase of this project focused on a feasibility study in 11 healthy able-bodied subjects. The results demonstrated substantial cardiopulmonary responses, no complications were found, and the method was deemed feasible. The second phase was to analyse validity and test-retest reliability of the primary CPET parameters obtained from the RATT in 18 healthy able-bodied subjects and to compare the outcomes to those obtained from standard exercise testing devices (a cycle ergometer and a treadmill). The results demonstrated that peak oxygen uptake (V'O2peak) and oxygen uptake at the submaximal exercise thresholds on the RATT were ̴20% lower than for the cycle ergometer and ̴30% lower than on the treadmill. A very high correlation was found between the RATT vs the cycle ergometer V'O2peak and the RATT vs the treadmill V'O2peak. Test-retest reliability of CPET parameters obtained from the RATT were similarly high to those for standard exercise testing devices. These findings suggested that the RATT is a valid and reliable device for CPET and that it has potential to be used in severely impaired patients. Thus, the third phase was to investigate using the RATT for CPET and exercise training in 8 severely disabled stroke patients. The method was technically implementable, well tolerated by the patients, and substantial cardiopulmonary responses were observed. Additionally, all patients could exercise at the recommended training intensity for 10 min bouts. Finally, an investigation of test-retest reliability and four-week changes in cardiopulmonary fitness was carried out in 17 stroke patients with various degrees of disability. Good to excellent test-retest reliability and repeatability were found for the main CPET variables. There was no significant difference in most CPET parameters over four weeks. In conclusion, based on the demonstrated validity, reliability and repeatability, the RATT was found to be a feasible and appropriate alternative exercise testing and training device for patients who have limitations for use of standard devices.