6 resultados para Ultrasound Screening

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Although routine ultrasound screening for abdominal aortic aneurysm (AAA) reduces mortality in subjects at risk, it is often omitted in clinical practice. Because computerized alerts may systematically identify subjects at risk of AAA, we hypothesized that such alerts would encourage physicians to perform an ultrasound screening test.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION For ultrasonographic diagnosis of a fetal trisomy so-called "soft markers" (=ultrasonographically detectable morphological variants) are used. Detection of a certain number of them increases the diagnostic certainty of a fetal trisomy. Up to now there are very few diagnostically accepted osseous soft markers for trisomy. Hence potential osseous soft markers applicable for first and second trimester ultrasound screening for trisomy 21, 18 or 13 were studied. METHODS Postmortal fetal X-rays (ap, lateral) of 358 fetuses (trisomy 21: n = 109, trisomy 18: n = 46; trisomy 13: n = 38, control group: n = 165). RESULTS Not yet described but with trisomy 21 statistically associated soft markers were un-timely os sternale ossification, delayed os sacrum ossification, shortened os maxillare, reduced os maxillare-jaw-corner distance, augmented orbita height, premature os calcaneus ossification, bell-shaped thorax, coronal clefts, trend to wider binocular as well as wider intraocular distances; for trisomy 18: elevated clavicula slope, reduced number of ribs, bell-shaped thorax, coronal clefts, reduced os maxillare-jaw-corner distance, shortened ramus mandibulare, shortened os metacarpale IV and V, augmented ratio between biparietal diameter and (osseus and soft-tissue) shoulder width; for trisomy 13: longer os nasale, elevated clavicula slope, premature sternum, delayed os sacrum ossification, delayed/premature cranium ossification, reduced number of ribs, coronal clefts, reduced os maxillare-jaw-corner distance, shortened ramus mandibulare, augmented orbita height, shortened os metacarpale V and a tendency for a shortened os metacarpale IV. CONCLUSION We found several not yet published osseous soft markers statistically associated with trisomy 21, 18 and 13, which can help to ensure sonographically these aneuploidy diagnoses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Isolated Horner syndrome without associated cranial nerve palsies or ischemic symptoms is an important presentation of spontaneous internal carotid artery dissection (sICAD). Ultrasound is often used as a screening method in these patients because cervical MRI is not always available on an emergency basis. Current knowledge on ultrasound findings in patients with sICAD presenting with isolated Horner syndrome is limited. METHODS: Patients were recruited from prospective cervical artery dissection databases of 3 tertiary care centers. Diagnosis of sICAD was confirmed by cervical MRI and MR angiography or digital subtraction angiography in all patients. Data on Doppler sonography and color duplex sonography examinations performed within 30 days of symptom onset were analyzed. RESULTS: We identified 88 patients with Horner syndrome as the only sign of sICAD. Initial ultrasound examination was performed in 72 patients after a mean time interval from symptom onset to examination of 11 (SD 8) days. The overall frequency of false-negative ultrasound findings was 31% (22 of 72 patients). It showed stenosis >or=80% or occlusion in 34 (47%) patients, and stenosis ultrasound were less frequently smokers (9% versus 28%, P=0.034), and had less frequently migraine without aura (9% versus 43%, P=0.012) or neck pain (18% versus 62%, P=0.003) than those with pathological ultrasound findings. CONCLUSIONS: Nearly one third of patients with Horner syndrome as the only sign of sICAD presented with normal ultrasound findings. These results indicate that ultrasound is not a reliable method to diagnose sICAD in patients with isolated Horner syndrome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To study the validity of both rheumatological and orthodontic examinations and ultrasound (US) as screening methods for early diagnosis of TMJ arthritis against the gold standard MRI. METHODS: Thirty consecutive juvenile idiopathic arthritis (JIA) patients were included in this pilot study. Rheumatological and orthodontic examinations as well as US were performed within 1 month of the MRI in a blinded fashion. Joint effusion and/or increased contrast enhancement of synovium or bone were considered signs of active arthritis on MRI. RESULTS: A total of 19/30 (63%) patients and 33/60 (55%) joints had signs of TMJ involvement on MRI. This was associated with condylar deformity in 9/19 (47%) patients and 15/33 (45%) joints. Rheumatological, orthodontic and US examinations correctly diagnosed 11 (58%), 9 (47%) and 6 (33%) patients, respectively, with active TMJ arthritis, but misdiagnosed 8 (42%), 10 (53%) and 12 (67%) patients, respectively, as having no signs of inflammation. The best predictor for active arthritis on MRI was a reduced maximum mouth opening. CONCLUSION: None of the methods tested was able to reliably predict the presence or absence of MRI-proven inflammation in the TMJ in our cohort of JIA patients. US was the least useful of all methods tested to exclude active TMJ arthritis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dual energy X-ray absorptiometry (DXA) is widely accepted as the reference method for diagnosis and monitoring of osteoporosis and for assessment of fracture risk, especially at hip. However, axial-DXA is not suitable for mass screening, because it is usually confined to specialized centers. We propose a two-step diagnostic approach to postmenopausal osteoporosis: the first step, using an inexpensive, widely available screening technique, aims at risk stratification in postmenopausal women; the second step, DXA of spine and hip is applied only to potentially osteoporotic women preselected on the basis of the screening measurement. In a group of 110 healthy postmenopausal woman, the capability of various peripheral bone measurement techniques to predict osteoporosis at spine and/or hip (T-score < -2.5SD using DXA) was tested using receiver operating characteristic (ROC) curves: radiographic absorptiometry of phalanges (RA), ultrasonometry at calcaneus (QUS. CALC), tibia (SOS.TIB), and phalanges (SOS.PHAL). Thirty-three women had osteoporosis at spine and/or hip with DXA. Areas under the ROC curves were 0.84 for RA, 0.83 for QUS.CALC, 0.77 for SOS.PHAL (p < 0.04 vs RA) and 0.74 for SOS.TIB (p < 0.02 vs RA and p = 0.05 vs QUS.CALC). For levels of sensitivity of 90%, the respective specificities were 67% (RA), 64% (QUS.CALC), 48% (SOS.PHAL), and 39% (SOS.TIB). In a cost-effective two-step, the price of the first step should not exceed 54% (RA), 51% (QUS.CALC), 42% (SOS.PHAL), and 25% (SOS.TIB). In conclusion, RA, QUS.CALC, SOS.PHAL, and SOS.TIB may be useful to preselect postmenopausal women in whom axial DXA is indicated to confirm/exclude osteoporosis at spine or hip.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Femoro-patellar dysplasia is considered as a significant risk factor of patellar instability. Different studies suggest that the shape of the trochlea is already developed in early childhood. Therefore early identification of a dysplastic configuration might be relevant information for the treating physician. An easy applicable routine screening of the trochlea is yet not available. The purpose of this study was to establish and evaluate a screening method for femoro-patellar dysplasia using 3D ultrasound. From 2012 to 2013 we prospectively imaged 160 consecutive femoro-patellar joints in 80 newborns from the 36th to 61st gestational week that underwent a routine hip sonography (Graf). All ultrasounds were performed by a pediatric radiologist with only minimal additional time to the routine hip ultrasound. In 30° flexion of the knee, axial, coronal, and sagittal reformats were used to standardize a reconstructed axial plane through the femoral condyle and the mid-patella. The sulcus angle, the lateral-to-medial facet ratio of the trochlea and the shape of the patella (Wiberg Classification) were evaluated. In all examinations reconstruction of the standardized axial plane was achieved, the mean trochlea angle was 149.1° (SD 4.9°), the lateral-to-medial facet ratio of the trochlea ratio was 1.3 (SD 0.22), and a Wiberg type I patella was found in 95% of the newborn. No statistical difference was detected between boys and girls. Using standardized reconstructions of the axial plane allows measurements to be made with lower operator dependency and higher accuracy in a short time. Therefore 3D ultrasound is an easy applicable and powerful tool to identify trochlea dysplasia in newborns and might be used for screening for trochlea dysplasia.