54 resultados para Ultra-high energies

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Retinal laser photocoagulation is an established and successful treatment for a variety of retinal diseases. While being a valuable treatment modality, laser photocoagulation shows the drawback of employing high energy lasers which are capable of physically destroying the neural retina. For reliable therapy, it is therefore crucial to closely monitor the therapy effects caused in the retinal tissue. A depth resolved representation of optical tissue properties as provided by optical coherence tomography may provide valuable information about the treatment effects in the retinal layers if recorded simultaneously to laser coagulation. Therefore, in this work, the use of ultra-high resolution optical coherence tomography to represent tissue changes caused by conventional and selective retinal photocoagulation is investigated. Laser lesions were placed on porcine retina ex-vivo using a 577 nm laser as well as a pulsed laser at 527 nm built for selective treatment of the retinal pigment epithelium. Applied energies were varied to generate lesions best representing the span from under- to overtreatment. The lesions were examined using a custom-designed optical coherence tomography system with an axial resolution of 1.78 μm and 70 kHz Ascan rate. Optical coherence tomography scans included volume scans before and after irradiation, as well as time lapse scans (Mscan) of the lesions. Results show OCT lesion visibility thresholds to be below the thresholds of ophthalmoscopic inspection. With the ultra-high resolution OCT, 42% - 44% of ophthalmoscopically invisible lesions could be detected and lesions that were under- or overexposed could be distinguished using the OCT data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study compares the performance and the reproducibility of quantitative T2, T2* and the magnetisation transfer ratio (MTR) of articular cartilage at 7T and 3T.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dental identification is the most valuable method to identify human remains in single cases with major postmortem alterations as well as in mass casualties because of its practicability and demanding reliability. Computed tomography (CT) has been investigated as a supportive tool for forensic identification and has proven to be valuable. It can also scan the dentition of a deceased within minutes. In the present study, we investigated currently used restorative materials using ultra-high-resolution dual-source CT and the extended CT scale for the purpose of a color-encoded, in scale, and artifact-free visualization in 3D volume rendering. In 122 human molars, 220 cavities with 2-, 3-, 4- and 5-mm diameter were prepared. With presently used filling materials (different composites, temporary filling materials, ceramic, and liner), these cavities were restored in six teeth for each material and cavity size (exception amalgam n = 1). The teeth were CT scanned and images reconstructed using an extended CT scale. Filling materials were analyzed in terms of resulting Hounsfield units (HU) and filling size representation within the images. Varying restorative materials showed distinctively differing radiopacities allowing for CT-data-based discrimination. Particularly, ceramic and composite fillings could be differentiated. The HU values were used to generate an updated volume-rendering preset for postmortem extended CT scale data of the dentition to easily visualize the position of restorations, the shape (in scale), and the material used which is color encoded in 3D. The results provide the scientific background for the application of 3D volume rendering to visualize the human dentition for forensic identification purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECT: Fat suppressed 3D steady-state free precession (SSFP) sequences are of special interest in cartilage imaging due to their short repetition time in combination with high signal-to-noise ratio. At low-to-high fields (1.5-3.0 T), spectral spatial (spsp) radio frequency (RF) pulses perform superiorly over conventional saturation of the fat signal (FATSAT pulses). However, ultra-high fields (7.0 T and more) may offer alternative fat suppression techniques as a result of the increased chemical shift. MATERIALS AND METHODS: Application of a single, frequency selective, RF pulse is compared to spsp excitation for water (or fat) selective imaging at 7.0 T. RESULTS: For SSFP, application of a single frequency selective RF pulse for selective water or fat excitation performs beneficially over the commonly applied spsp RF pulses. In addition to the overall improved fat suppression, the application of single RF pulses leads to decreased power depositions, still representing one of the major restrictions in the design and application of many pulse sequences at ultra-high fields. CONCLUSION: The ease of applicability and implementation of single frequency selective RF pulses at ultra-high-fields might be of great benefit for a vast number of applications where fat suppression is desirable or fat-water separation is needed for quantification purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Cognitive impairments are regarded as a core component of schizophrenia. However, the cognitive dimension of psychosis is hardly considered by ultra-high risk (UHR) criteria. Therefore, we studied whether the combination of symptomatic UHR criteria and the basic symptom criterion "cognitive disturbances" (COGDIS) is superior in predicting first-episode psychosis. METHOD In a naturalistic 48-month follow-up study, the conversion rate to first-episode psychosis was studied in 246 outpatients of an early detection of psychosis service (FETZ); thereby, the association between conversion, and the combined and singular use of UHR criteria and COGDIS was compared. RESULTS Patients that met UHR criteria and COGDIS (n=127) at baseline had a significantly higher risk of conversion (hr=0.66 at month 48) and a shorter time to conversion than patients that met only UHR criteria (n=37; hr=0.28) or only COGDIS (n=30; hr=0.23). Furthermore, the risk of conversion was higher for the combined criteria than for UHR criteria (n=164; hr=0.56 at month 48) and COGDIS (n=158; hr=0.56 at month 48) when considered irrespective of each other. CONCLUSIONS Our findings support the merits of considering both COGDIS and UHR criteria in the early detection of persons who are at high risk of developing a first psychotic episode within 48months. Applying both sets of criteria improves sensitivity and individual risk estimation, and may thereby support the development of stage-targeted interventions. Moreover, since the combined approach enables the identification of considerably more homogeneous at-risk samples, it should support both preventive and basic research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ex vivo porcine retina laser lesions applied with varying laser power (20 mW–2 W, 10 ms pulse, 196 lesions) are manually evaluated by microscopic and optical coherence tomography (OCT) visibility, as well as in histological sections immediately after the deposition of the laser energy. An optical coherence tomography system with 1.78 um axial resolution specifically developed to image thin retinal layers simultaneously to laser therapy is presented, and visibility thresholds of the laser lesions in OCT data and fundus imaging are compared. Optical coherence tomography scans are compared with histological sections to estimate the resolving power for small optical changes in the retinal layers, and real-time time-lapse scans during laser application are shown and analyzed quantitatively. Ultrahigh-resolution OCT inspection features a lesion visibility threshold 40–50 mW (17 reduction) lower than for visual inspection. With the new measurement system, 42 of the lesions that were invisible using state-of-the-art ophthalmoscopic methods could be detected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The CHaracterising ExOPlanet Satellite (CHEOPS) is a joint ESA-Switzerland space mission (expected to launch in 2017) dedicated to search for exoplanet transits by means of ultra-high precision photometry. CHEOPS will provide accurate radii for planets down to Earth size. Targets will mainly come from radial velocity surveys. The CHEOPS instrument is an optical space telescope of 30 cm clear aperture with a single focal plane CCD detector. The tube assembly is passively cooled and thermally controlled to support high precision, low noise photometry. The telescope feeds a re-imaging optic, which supports the straylight suppression concept to achieve the required Signal to Noise. © (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Selective retina therapy (SRT) has shown great promise compared to conventional retinal laser photocoagulation as it avoids collateral damage and selectively targets the retinal pigment epithelium (RPE). Its use, however, is challenging in terms of therapy monitoring and dosage because an immediate tissue reaction is not biomicroscopically discernibel. To overcome these limitations, real-time optical coherence tomography (OCT) might be useful to monitor retinal tissue during laser application. We have thus evaluated a proprietary OCT system for its capability of mapping optical changes introduced by SRT in retinal tissue. Methods: Freshly enucleated porcine eyes, covered in DMEM upon collection were utilized and a total of 175 scans from ex-vivo porcine eyes were analyzed. The porcine eyes were used as an ex-vivo model and results compared to two time-resolved OCT scans, recorded from a patient undergoing SRT treatment (SRT Vario, Medical Laser Center Lübeck). In addition to OCT, fluorescin angiography and fundus photography were performed on the patient and OCT scans were subsequently investigated for optical tissue changes linked to laser application. Results: Biomicroscopically invisible SRT lesions were detectable in OCT by changes in the RPE / Bruch's complex both in vivo and the porcine ex-vivo model. Laser application produced clearly visible optical effects such as hyperreflectivity and tissue distortion in the treated retina. Tissue effects were even discernible in time-resolved OCT imaging when no hyper-reflectivity persisted after treatment. Data from ex-vivo porcine eyes showed similar to identical optical changes while effects visible in OCT appeared to correlate with applied pulse energy, leading to an additional reflective layer when lesions became visible in indirect ophthalmoscopy. Conclusions: Our results support the hypothesis that real-time high-resolution OCT may be a promising modality to obtain additional information about the extent of tissue damage caused by SRT treatment. Data shows that our exvivo porcine model adequately reproduces the effects occurring in-vivo, and thus can be used to further investigate this promising imaging technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Early detection of psychosis is an important topic in psychiatry. Yet, there is limited information on the prevalence and clinical significance of high-risk symptoms in children and adolescents as compared to adults. We examined ultra-high-risk (UHR) symptoms and criteria in a sample of individuals aged 8-40 years from the general population of Canton Bern, Switzerland, enrolled from June 2011 to May 2014. The current presence of attenuated psychotic symptoms (APS) and brief intermittent psychotic symptoms (BLIPS) and the fulfillment of onset/worsening and frequency requirements for these symptoms in UHR criteria were assessed using the Structured Interview for Psychosis Risk Syndromes. Additionally, perceptive and non-perceptive APS were differentiated. Psychosocial functioning and current non-psychotic DSM-IV axis I disorders were also surveyed. Well-trained psychologists performed assessments. Altogether, 9.9% of subjects reported APS and none BLIPS, and 1.3% met all the UHR requirements for APS. APS were related to more current axis I disorders and impaired psychosocial functioning, indicating some clinical significance. A strong age effect was detected around age 16: compared to older individuals, 8-15-year olds reported more perceptive APS, that is, unusual perceptual experiences and attenuated hallucinations. Perceptive APS were generally less related to functional impairment, regardless of age. Conversely, non-perceptive APS were related to low functioning, although this relationship was weaker in those below age 16. Future studies should address the differential effects of perceptive and non-perceptive APS, and their interaction with age, also in terms of conversion to psychosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective The validity of current ultra-high risk (UHR) criteria is under-examined in help-seeking minors, particularly, in children below the age of 12 years. Thus, the present study investigated predictors of one-year outcome in children and adolescents (CAD) with UHR status. Method Thirty-five children and adolescents (age 9–17 years) meeting UHR criteria according to the Structured Interview for Psychosis-Risk Syndromes were followed-up for 12 months. Regression analyses were employed to detect baseline predictors of conversion to psychosis and of outcome of non-converters (remission and persistence of UHR versus conversion). Results At one-year follow-up, 20% of patients had developed schizophrenia, 25.7% had remitted from their UHR status that, consequently, had persisted in 54.3%. No patient had fully remitted from mental disorders, even if UHR status was not maintained. Conversion was best predicted by any transient psychotic symptom and a disorganized communication score. No prediction model for outcome beyond conversion was identified. Conclusions Our findings provide the first evidence for the predictive utility of UHR criteria in CAD in terms of brief intermittent psychotic symptoms (BIPS) when accompanied by signs of cognitive impairment, i.e. disorganized communication. However, because attenuated psychotic symptoms (APS) related to thought content and perception were indicative of non-conversion at 1-year follow-up, their use in early detection of psychosis in CAD needs further study. Overall, the need for more in-depth studies into developmental peculiarities in the early detection and treatment of psychoses with an onset of illness in childhood and early adolescence was further highlighted.