34 resultados para USERS

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To test whether in-the-canal (ITC) microphones have an impact on spatial discrimination and speech perception by taking advantage of auricular cues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To analyze alcohol use, clinical data and laboratory parameters that may affect FIB-4, an index for measuring liver fibrosis, in HCV-monoinfected and HCV/HIV-coinfected drug users. Patients and Methods Patients admitted for substance abuse treatment between 1994 and 2006 were studied. Socio-demographic data, alcohol and drug use characteristics and clinical variables were obtained through hospital records. Blood samples for biochemistry, liver function tests, CD4 cell count, and serology of HIV and HCV infection were collected at admission. Multivariate linear regression was used to analyze the predictors of FIB-4 increase. Results A total of 472 (83% M, 17% F) patients were eligible. The median age at admission was 31 years (Interquartile range (IQR) 27–35 years), and the median duration of drug use was 10 years (IQR 5.5–15 years). Unhealthy drinking (>50 grams/day) was reported in 32% of the patients. The FIB-4 scores were significantly greater in the HCV/HIV-coinfected patients (1.14, IQR 0.76–1.87) than in the HCV-monoinfected patients (0.75, IQR 0.56–1.11) (p<0.001). In the multivariate analysis, unhealthy drinking (p = 0.034), lower total cholesterol (p = 0.042), serum albumin (p<0.001), higher GGT (p<0.001) and a longer duration of addiction (p = 0.005) were independently associated with higher FIB-4 scores in the HCV-monoinfected drug users. The effect of unhealthy drinking on FIB-4 scores disappeared in the HCV/HIV-coinfected patients, whereas lower serum albumin (p<0.001), a lower CD4 cell count (p = 0.006), higher total bilirubin (p<0.001) and a longer drug addiction duration (p<0.001) were significantly associated with higher FIB-4 values. Conclusions Unhealthy alcohol use in the HCV-monoinfected patients and HIV-related immunodeficiency in the HCV/HIV-coinfected patients are important risk factors associated with liver fibrosis in the respective populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study is to evaluate the effects of high doses of injected opiates as prescribed maintenance in intravenous drugs users. This was accomplished via a randomised double-blind study with crossover at an outpatient clinic in Bern, Switzerland. The subjects were 39 patients with a long history of intravenous opioid use and persistent abuse despite treatment; they were randomly allocated to two groups. Group A was started on controlled injection of graduated doses of morphine up to a satisfying individual dose and was then switched as a double blind to heroin at a randomly determined day between week three and four. Subsequently this group was given heroin for the remaining two to three weeks of the study. Group B was started on heroin and was then switched to morphine in the same manner. Equipotent solutions of 3% morphine and 2% heroin were administered. The main outcome measures were clinical observations, structural interviews and self report of subjective experiences to assess the effects of the drugs. In 16 cases, the study had to be discontinued owing to severe morphine-induced histamine reactions. Thirteen participants in Group B presented these adverse reactions on the day of the switch-over. Full data were thus only obtainable for 17 participants. Average daily doses were 491 mg for heroin and 597 mg for morphine. The findings indicate that heroin significantly produced a lower grade of itching, flushing, urticaria and pain/nausea. A negative correlation between dose and euphoria was observed for both heroin and morphine. The authors concluded that as heroin produces fewer side effects it is the preferred high-dose maintenance prescription to morphine. The perceived euphoric effects are limited in both substances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Speech coding might have an impact on music perception of cochlear implant users. This questionnaire study compares the musical activities and perception of postlingually deafened cochlear implant users with three different coding strategies (CIS, ACE, SPEAK) using the Munich Music Questionnaire. Overall, the self-reported perception of music of CIS, SPEAK, and ACE users did not differ by very much.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe an outbreak among drug users of severe soft-tissue infections caused by a clonal strain of group A streptococcus of M-type 25. Cases (n = 19) in drug users were defined as infections (mainly needle abscesses) due to the outbreak strain. Comparison with controls showed that infected drug users bought drugs more often at a specific place. Drug purchase and use habits may have contributed to this outbreak.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endocarditis is a relatively frequent infection in intravenous drug users. We compared features in the cases of 102 patients with those in intravenous drug users with other causes of fever to identify risk factors predictive of endocarditis. Logistic regression analysis showed cocaine use to be strongly associated with endocarditis. This special risk involving cocaine use has not been reported previously; the explanation for it may provide insight into the pathogenesis of endocarditis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Users of cochlear implant systems, that is, of auditory aids which stimulate the auditory nerve at the cochlea electrically, often complain about poor speech understanding in noisy environments. Despite the proven advantages of multimicrophone directional noise reduction systems for conventional hearing aids, only one major manufacturer has so far implemented such a system in a product, presumably because of the added power consumption and size. We present a physically small (intermicrophone distance 7 mm) and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. Supporting algorithms, which allow the adjustment of the opening angle and the maximum noise suppression, are proposed and evaluated. A portable real-time device for test in real acoustic environments is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Users of cochlear implants (auditory aids, which stimulate the auditory nerve electrically at the inner ear) often suffer from poor speech understanding in noise. We evaluate a small (intermicrophone distance 7 mm) and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. The system is evaluated in simulated and real, anechoic and reverberant environments. Results from simulations show improvements of 3.4 to 9.3 dB in signal to noise ratio for rooms with realistic reverberation and more than 18 dB under anechoic conditions. Speech understanding in noise is measured in 6 adult cochlear implant users in a reverberant room, showing average improvements of 7.9–9.6 dB, when compared to a single omnidirectional microphone or 1.3–5.6 dB, when compared to a simple directional two-microphone device. Subjective evaluation in a cafeteria at lunchtime shows a preference of the cochlear implant users for the evaluated device in terms of speech understanding and sound quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Music plays an important role in the daily life of cochlear implant (CI) users, but electrical hearing and speech processing pose challenges for enjoying music. Studies of unilateral CI (UCI) users' music perception have found that these subjects have little difficulty recognizing tempo and rhythm but great difficulty with pitch, interval and melody. The present study is an initial step towards understanding music perception in bilateral CI (BCI) users. The Munich Music Questionnaire was used to investigate music listening habits and enjoyment in 23 BCI users compared to 2 control groups: 23 UCI users and 23 normal-hearing (NH) listeners. Bilateral users appeared to have a number of advantages over unilateral users, though their enjoyment of music did not reach the level of NH listeners.