11 resultados para Tunneled central catheter

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: Compare changes in P-wave amplitude of the intra-atrial electrocardiogram (ECG) and its corresponding transesophageal echocardiography (TEE)-controlled position to verify the exact localization of a central venous catheter (CVC) tip. DESIGN: A prospective study. SETTING: University, single-institutional setting. PARTICIPANTS: Two hundred patients undergoing elective cardiac surgery. INTERVENTIONS: CVC placement via the right internal jugular vein with ECG control using the guidewire technique and TEE control in 4 different phases: phase 1: CVC placement with normalized P wave and measurement of distance from the crista terminalis to the CVC tip; phase 2: TEE-controlled placement of the CVC tip; parallel to the superior vena cava (SVC) and measurements of P-wave amplitude; phase 3: influence of head positioning on CVC migration; and phase 4: evaluation of positioning of the CVC postoperatively using a chest x-ray. MEASUREMENTS AND MAIN RESULTS: The CVC tip could only be visualized in 67 patients on TEE with a normalized P wave. In 198 patients with the CVC parallel to the SVC wall controlled by TEE (phase 2), an elevated P wave was observed. Different head movements led to no significant migration of the CVC (phase 3). On a postoperative chest-x-ray, the CVC position was correct in 87.6% (phase 4). CONCLUSION: The study suggests that the position of the CVC tip is located parallel to the SVC and 1.5 cm above the crista terminalis if the P wave starts to decrease during withdrawal of the catheter. The authors recommend that ECG control as per their study should be routinely used for placement of central venous catheters via the right internal jugular vein.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. MATERIALS AND METHODS: Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. RESULTS: Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. CONCLUSION: Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

When used in veterinary medicine, central venous catheters are typically inserted through the external jugular vein, with their caudal extension within the cranial vena cava. Radiographic or fluoroscopic guidance is recommended to assist in correctly placing these catheters. This article provides radiologic examples of common central venous catheter malpositions and complications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The pulmonary artery catheter (PAC) is a powerful tool that has been used extensively in the assessment and monitoring of cardiovascular physiology. Gross misinterpretation of data gathered by the PAC is common, and its routine use without any specific interventions has not been shown to influence outcome. However, there currently is no evidence from randomized, controlled trials that any diagnostic or monitoring tool used in intensive care patients improves outcome. Studies evaluating the use of the PAC have included numerous potential confounding factors, and should be interpreted with caution. The information obtained with the PAC should be used to find better treatment strategies, and these strategies, instead of the tool itself, should be tested in clinical trials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The tradition of yearly reports on cardiac catheter interventions in Europe has been initiated in 1992. This 11th report presents aggregated data on cardiac catheter procedures in 30 European countries in the year 2002. DESIGN AND SETTING: A detailed questionnaire addressing summary data of all cardiac interventions was mailed to presidents or delegates of the national societies of cardiology in Europe. The questionnaire was distributed to all institutions with cardiac catheterisation programs. All questionnaires were compiled in a national summary data sheet, then entered into a central database and subsequently analysed. MAIN OUTCOME MEASURES: Coronary angiography, PTCA, and stenting in absolute numbers and per million inhabitants in the participating countries and the whole of Europe. RESULTS: Overall, 1,901,932 coronary angiograms were reported. The population-adjusted rate of coronary angiograms amounted to an absolute mean of 3358 per 10(6) inhabitants, an increase of 7% compared with 2001. A total of 686,869 PTCA procedures were reported. The mean European number of PTCAs per 10(6) inhabitants increased by 10% from 1103 in 2001 to 1213 in 2002. Procedures with stenting increased by 17% from 508,999 to 593,906. The stenting rate was 86% compared with 82% in 2001. CONCLUSIONS: In pace with epidemiological demand and the need to catch-up from underuse in certain countries, a continuous and considerable growth of coronary interventions can be observed. It will take years to find out whether the announced change of paradigm in the treatment of multivessel disease in the wake of drug-eluting stents will come true.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Central venous catheters are established as vascular access in hemodialysis therapy. Vascular catheter misdirection may occur and is a well known problem. We present a rare catheter malposition in a young dialysis patient with consequent dilatation of the azygos vein system, simulating the appearance of an azygos continuation syndrome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: It has been shown that early central venous oxygen saturation (ScvO2)-guided optimization of hemodynamics can improve outcome in septic patients. The early ScvO2 profile of other patient groups is unknown. The aim of this study was to characterize unplanned admissions in a multidisciplinary intensive care unit (ICU) with respect to ScvO2 and outcome. METHODS: Ninety-eight consecutive unplanned admissions to a multidisciplinary ICU (median age 63 [range 19 to 83] years, median Simplified Acute Physiology Score [SAPS II] 43 [range 11 to 92]) with a clinical indication for a central venous catheter were included in the study. ScvO2 was assessed at ICU arrival and six hours later but was not used to guide treatment. Length of stay in ICU (LOSICU) and in hospital (LOShospital) and 28-day mortality were recorded. RESULTS: ScvO2 was 70% +/- 12% (mean +/- standard deviation) at admission and 71% +/- 10% six hours later (p = 0.484). Overall 28-day mortality was 18%, LOSICU was 3 (1 to 28) days, and LOShospital was 19 (1 to 28) days. Patients with an ScvO2 of less than 60% at admission had higher mortality than patients with an ScvO2 of more than 60% (29% versus 17%, p < 0.05). Changes in ScvO2 during the first six hours were not predictive of LOSICU, LOShospital, or mortality. CONCLUSION: Low ScvO2 in unplanned admissions and high SAPS II are associated with increased mortality. Standard ICU treatment increased ScvO2 in patients with a low admission ScvO2, but the increase was not associated with LOSICU or LOShospital.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Early catheter-related infection is a serious complication in cancer treatment, although risk factors for its occurrence are not well established. The authors conducted a prospective study to identify the risk factors for developing early catheter-related infection. METHODS: All consecutive patients with cancer who underwent insertion of a central venous catheter were enrolled and were followed prospectively during 1 month. The study endpoint was occurrence of early catheter-related infection. RESULTS: Over 10,392 catheter-days of follow-up, 14 of 371 patients had early catheter-related infections (14 patients in 10,392 catheter-days or 1.34 per 1000 catheter-days). The causative pathogens were gram positive in 11 of 14 patients. In univariate analysis, the risk factors for early catheter-related infection were aged <10 years (P = .0001), difficulties during insertion (P < 10(-6)), blood product administration (P < 10(-3)), parenteral nutrition (P < 10(-4)), and use >2 days (P < 10(-6)). In multivariate analysis, 3 variables remained significantly associated with the risk of early catheter-related infection: age <10 years (odds ratio [OR], 18.4; 95% confidence interval [95% CI], 1.9-106.7), difficulties during insertion procedure (OR, 25.6; 95% CI, 4.2-106), and parenteral nutrition (OR, 28.5; 95% CI, 4.2-200). CONCLUSIONS: On the day of insertion, 2 variables were identified that were associated with a high risk of developing an early catheter-related infection: young age and difficulties during insertion. The results from this study may be used to identify patients who are at high risk of infection who may be candidates for preventive strategies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Enterococci are an important cause of central venous catheter (CVC)-associated bloodstream infections (CA-BSI). It is unclear whether CVC removal is necessary to successfully manage enterococcal CA-BSI. METHODS A 12-month retrospective cohort study of adults with enterococcal CA-BSI was conducted at a tertiary care hospital; clinical, microbiological and outcome data were collected. RESULTS A total of 111 patients had an enterococcal CA-BSI. The median age was 58.2 years (range 21 to 94 years). There were 45 (40.5%) infections caused by Entercoccus faecalis (among which 10 [22%] were vancomycin resistant), 61 (55%) by Enterococcus faecium (57 [93%] vancomycin resistant) and five (4.5%) by other Enterococcus species. Patients were treated with linezolid (n=51 [46%]), vancomycin (n=37 [33%]), daptomycin (n=11 [10%]), ampicillin (n=2 [2%]) or quinupristin/dalfopristin (n=2 [2%]); seven (n=6%) patients did not receive adequate enterococcal treatment. Additionally, 24 (22%) patients received adjunctive gentamicin treatment. The CVC was retained in 29 (26.1%) patients. Patients with removed CVCs showed lower rates of in-hospital mortality (15 [18.3%] versus 11 [37.9]; P=0.03), but similar rates of recurrent bacteremia (nine [11.0%] versus two (7.0%); P=0.7) and a similar post-BSI length of hospital stay (median days [range]) (11.1 [1.7 to 63.1 days] versus 9.3 [1.9 to 31.8 days]; P=0.3). Catheter retention was an independent predictor of mortality (OR 3.34 [95% CI 1.21 to 9.26]). CONCLUSIONS To the authors' knowledge, the present article describes the largest enterococcal CA-BSI series to date. Mortality was increased among patients who had their catheter retained. Additional prospective studies are necessary to determine the optimal management of enterococcal CA-BSI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Exposure to urinary catheters is considered the most important risk factor for healthcare-associated urinary tract infection (UTI) and is associated with significant morbidity and substantial extra-costs. In this study, we assessed the impact of urinary catheterisation (UC) on symptomatic healthcare-associated UTI among hospitalized patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND For chronic subdural hematoma, placement of a Blake drain with a two-burr-hole craniotomy is often preferred. However, the placement of such drains carries the risk of penetrating the brain surface or damaging superficial venous structures. OBJECTIVE To describe the use of a Nelaton catheter for the placement of a subdural drain in two-burr-hole trephination for chronic subdural hematoma. METHOD A Nelaton catheter was used to guide placement of a Blake drain into the subdural hematoma cavity and provide irrigation of the hematoma cavity. With the two-burr-hole method, the Nelaton catheter could be removed easily via the frontal burr hole after the Blake drain was in place. RESULTS We used the Nelaton catheters in many surgical procedures and found it a safe and easy technique. This method allows the surgeon to safely direct the catheter into the correct position in the subdural space. CONCLUSIONS This tool has two advantages. First, the use of a small and flexible Nelaton catheter is a safe method for irrigation of a chronic subdural hematoma cavity. Second, in comparison with insertion of subdural drainage alone through a burr hole, the placement of the Nelaton catheter in subdural space is easier and the risk of damaging relevant structures such as cortical tissue or bridging veins is lower. Thus this technique may help to avoid complications when placing a subdural drain.