17 resultados para Treadmill running

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to determine a stress response, two groups of twenty male golden hamsters were either exposed to a ferret or handled by a human. The hamsters' body temperature and running wheel activity were measured as stress correlates. Half of the hamsters' cages were equipped with a functional running wheel to determine whether the presence of a running wheel might reduce stress. Exposure to the ferret was followed by a significant increase in body temperature and running wheel revolutions: however, running wheel activity did not change after handling. Body temperature increased less after handling in hamsters living in a cage with a functional running wheel than in those with a non-revolving running wheel. This suggests that hamsters with a functional running wheel reacted less strongly to acute stress caused by handling. On the other hand, temperature increase after the exposure to a ferret was not affected by the presence of a running wheel. Both exposure to a ferret and handling caused stress in golden hamsters, as demonstrated by an increase in body temperature (emotional fever). Stress caused by handling was much milder than stress caused by the ferret. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exercise intolerance may be reported by parents of young children with respiratory diseases. There is, however, a lack of standardized exercise protocols which allow verification of these reports especially in younger children. Consequently the aims of this pilot study were to develop a standardized treadmill walking test for children aged 4-10 years demanding low sensorimotor skills and achieving high physical exhaustion. In a prospective experimental cross sectional pilot study, 33 healthy Caucasian children were separated into three groups: G1 (4-6 years, n = 10), G2 (7-8 years, n = 12), and G3 (9-10 years, n = 11). Children performed the treadmill walking test with increasing exercise levels up to peak condition with maximal exhaustion. Gas exchange, heart rate, and lactate were measured during the test, spirometry before and after. Parameters were statistically calculated at all exercise levels as well as at 2 and 4 mmol/L lactate level for group differences (Kruskal-Wallis H-test, alpha = 0.05; post hoc: Mann-Whitney U-test with Bonferroni correction alpha = 0.05/n) and test-retest differences (Wilcoxon-rank-sum test) with SPSS. The treadmill walking test could be demonstrated to be feasible with a good repeatability within groups for most of the parameters. All children achieved a high exhaustion level. At peak level under exhaustion condition only the absolute VO2 and VCO2 differed significantly between age groups. In conclusion this newly designed treadmill walking test indicates a good feasibility, safety, and repeatability. It suggests the potential usefulness of exercise capacity monitoring for children aged from early 4 to 10 years. Various applications and test modifications will be investigated in further studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lumbar spinal stenosis is a frequent indication for spinal surgery. The predictive quality of treadmill testing and MRI for diagnostic verification is not yet clearly defined. Aim of the current study was to assess correlations between treadmill testing and MRI findings in the lumbar spine. Twenty-five patients with lumbar spinal stenosis were prospectively examined. Treadmill tests were performed and the area of the dural sac and neuroforamina was examined with MRI for the narrowest spinal segment. VAS and ODI were used for clinical assessment. The median age of the patients was 67 years. In the narrowest spinal segment the median area of the dural sac was 91 mm(2). The median ODI was 66 per cent. The median walking distance in the treadmill test was 70 m. The distance reached in the treadmill test correlated with the area of the dural sac (Spearman's rho = 0.53) and ODI (rho = -0.51), but not with the area of the neuroforamina and VAS. The distance reached in the treadmill test predicts the grade of stenosis in MRI but has a limited diagnostic importance for the level of clinical symptoms in lumbar spinal stenosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although U-clip anastomoses were studied for hemodynamics and patency, their potential for unimpeded growth after congenital cardiovascular surgery has not been investigated yet. In 53 children aged 2.1+/-3.3 years operated on between March 1998 and August 2005 growth of U-clip (U) vs. polypropylene running sutured (P) anastomoses in coarctation repair (Coarc; n=26), bi-directional Glenn (BDG; n=13) and arterial switch operation (ASO; n=14) was retrospectively analysed. Coarc showed 2.39+/-4.33 vs. 3.09+/-2.24 mm of growth during the observation period (21+/-16 vs. 30+/-27 months); no growth (0 vs.16%), restenosis (14 vs. 37%) and reinterventions (14 vs. 11%) were similar (all in U vs. P, P=ns). BDG showed 3.68+/-3.43 vs. 2.50+/-2.55 mm (P=ns) of growth during 15+/-5 vs. 29+/-18 months (P=0.046); no growth (17 vs. 0%), stenosis (0 vs. 14%) and reinterventions (0%) were similar in U vs. P, respectively (P=ns). Main pulmonary artery (MPA) anastomosis in ASO showed 0.28+/-1.73 vs. 1.30+/-3.16 mm of growth during 8+/-14 vs. 28+/-28 months; no growth (60 vs. 14%), stenosis (50 vs. 63%) and reinterventions (0%) were similar (all in U vs. P, P=ns). Anastomotic growth, stenosis and reintervention rates show no difference between interrupted U-clip and polypropylene running sutured technique in Coarc repair, BDG and MPA anastomosis in ASO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zum 65. Geburtstag von Prof. Dr. iur. et lic. oec. Heinrich Koller, haben über 40 Mitarbeiterinnen und Mitarbeiter des Bundesamtes für Justiz (BJ) eine Festschrift für ihren scheidenden Direktor verfasst. Die in deutscher und französischer Sprache verfassten Beiträge spiegeln das breite Spektrum einer Institution, aus deren «atelier» manch ein Gesetzesentwurf stammt. Oft übersehen wird dabei, dass das BJ aber auch eine «Werkstatt» ist, die das geltende Recht umsetzt und im Rahmen dieser Konkretisierung wichtige Akzente setzt. Die Festschrift bietet damit einen Blick hinter die Kulissen eines wichtigen Kompetenzzentrums für Rechtsfragen und beleuchtet aktuelle Probleme aus «erster Hand». Abgerundet wird die Festschrift mit einem Grusswort des Vorstehers EJPD (Bundesrat Christoph Blocher) und einem Schriftenverzeichnis von Heinrich Koller. Enthalten ist unter Anderem - die Bundesverfassung - weitere wichtige Gesetze und Verordnungen aus dem öffentlichen Recht - ZGB und Nebenerlasse - OR und Nebenerlasse - Erlasse zum Strafrecht und zur Strafrechtspflege - Gesetze zu Gesundheit, Arbeit und sozialer Sicherheit - wichtige Gesetze zu Wirtschaft und Kredit Autorinnen und Autoren Mitarbeiterinnen und Mitarbeiter des Bundesamtes für Justiz

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite antibiotic therapy and supportive intensive medical care, bacterial meningitis remains a disease with high mortality and morbidity. Rapid recognition of symptoms is crucial to direct physicians quickly towards appropriate diagnostic measures and, initially, empiric antibiotic therapy. It has become evident that time from arrival at the hospital to application of the first dose of antibiotics is a crucial independent factor that influences outcome. Here, we review the clinical and laboratory presentation of community-acquired bacterial meningitis and the antibiotic regiments that are currently recommended for its treatment; future therapeutic options are also discussed. Finally, suggestions for the approach to a patient with suspected bacterial meningitis are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION AND HYPOTHESIS The prevalence of female stress urinary incontinence is high, and young adults are also affected, including athletes, especially those involved in "high-impact" sports. To date there have been almost no studies testing pelvic floor muscle (PFM) activity during dynamic functional whole body movements. The aim of this study was the description and reliability test of PFM activity and time variables during running. METHODS A prospective cross-sectional study including ten healthy female subjects was designed with the focus on the intra-session test-retest reliability of PFM activity and time variables during running derived from electromyography (EMG) and accelerometry. RESULTS Thirteen variables were identified based on ten steps of each subject: Six EMG variables showed good reliability (ICC 0.906-0.942) and seven time variables did not show good reliability (ICC 0.113-0.731). Time variables (e.g. time difference between heel strike and maximal acceleration of vaginal accelerator) showed low reliability. However, relevant PFM EMG variables during running (e.g., pre-activation, minimal and maximal activity) could be identified and showed good reliability. CONCLUSION Further adaptations regarding measurement methods should be tested to gain better control of the kinetics and kinematics of the EMG probe and accelerometers. To our knowledge this is the first study to test the reliability of PFM activity and time variables during dynamic functional whole body movements. More knowledge of PFM activity and time variables may help to provide a deeper insight into physical strain with high force impacts and important functional reflexive contraction patterns of PFM to maintain or to restore continence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Robotics-assisted tilt table (RATT) technology provides body support, cyclical stepping movement and physiological loading. This technology can potentially be used to facilitate the estimation of peak cardiopulmonary performance parameters in patients who have neurological or other problems that may preclude testing on a treadmill or cycle ergometer. The aim of the study was to compare the magnitude of peak cardiopulmonary performance parameters including peak oxygen uptake (VO2peak) and peak heart rate (HRpeak) obtained from a robotics-assisted tilt table (RATT), a cycle ergometer and a treadmill. The strength of correlations between the three devices, test-retest reliability and repeatability were also assessed. Eighteen healthy subjects performed six maximal exercise tests, with two tests on each of the three exercise modalities. Data from the second tests were used for the comparative and correlation analyses. For nine subjects, test-retest reliability and repeatability of VO2peak and HRpeak were assessed. Absolute VO2peak from the RATT, the cycle ergometer and the treadmill was (mean (SD)) 2.2 (0.56), 2.8 (0.80) and 3.2 (0.87) L/min, respectively (p < 0.001). HRpeak from the RATT, the cycle ergometer and the treadmill was 168 (9.5), 179 (7.9) and 184 (6.9) beats/min, respectively (p < 0.001). VO2peak and HRpeak from the RATT vs the cycle ergometer and the RATT vs the treadmill showed strong correlations. Test-retest reliability and repeatability were high for VO2peak and HRpeak for all devices. The results demonstrate that the RATT is a valid and reliable device for exercise testing. There is potential for the RATT to be used in severely impaired subjects who cannot use the standard modalities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The robotics-assisted tilt table (RATT), including actuators for tilting and cyclical leg movement, is used for rehabilitation of severely disabled neurological patients. Following further engineering development of the system, i.e. the addition of force sensors and visual bio-feedback, patients can actively participate in exercise testing and training on the device. Peak cardiopulmonary performance parameters were previously investigated, but it also important to compare submaximal parameters with standard devices. The aim of this study was to evaluate the feasibility of the RATT for estimation of submaximal exercise thresholds by comparison with a cycle ergometer and a treadmill. METHODS: 17 healthy subjects randomly performed six maximal individualized incremental exercise tests, with two tests on each of the three exercise modalities. The ventilatory anaerobic threshold (VAT) and respiratory compensation point (RCP) were determined from breath-by-breath data. RESULTS: VAT and RCP on the RATT were lower than the cycle ergometer and the treadmill: oxygen uptake (V'O2) at VAT was [mean (SD)] 1.2 (0.3), 1.5 (0.4) and 1.6 (0.5) L/min, respectively (p < 0.001); V'O2 at RCP was 1.7 (0.4), 2.3 (0.8) and 2.6 (0.9) L/min, respectively (p = 0.001). High correlations for VAT and RCP were found between the RATT vs the cycle ergometer and RATT vs the treadmill (R on the range 0.69-0.80). VAT and RCP demonstrated excellent test-retest reliability for all three devices (ICC from 0.81 to 0.98). Mean differences between the test and retest values on each device were close to zero. The ventilatory equivalent for O2 at VAT for the RATT and cycle ergometer were similar and both were higher than the treadmill. The ventilatory equivalent for CO2 at RCP was similar for all devices. Ventilatory equivalent parameters demonstrated fair-to-excellent reliability and repeatability. CONCLUSIONS: It is feasible to use the RATT for estimation of submaximal exercise thresholds: VAT and RCP on the RATT were lower than the cycle ergometer and the treadmill, but there were high correlations between the RATT vs the cycle ergometer and vs the treadmill. Repeatability and test-retest reliability of all submaximal threshold parameters from the RATT were comparable to those of standard devices.