220 resultados para Transplantation heterologous
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
A 52-yr-old man presented with hematuria and clot retention. He had undergone simultaneous pancreas-kidney transplantation with exocrine pancreas bladder drainage 16 yr ago. The patient suffered from progressive transplant kidney failure with gradually decreasing urine output and needed hemodialysis every other day. Gross hematuria persisted after removal of all blood clots. Cystoscopy showed multiple small, flat ulcers of the bladder mucosa. Some bled discretely and were coagulated cautiously. However, hematuria was refractory to multiple urological interventions, which eventually necessitated an enteric diversion of the exocrine pancreas. Hematuria ceased following an uneventful postoperative course.
Resumo:
Atrial flutter in the donor part of orthotopic heart transplants has been reported and successfully treated by radiofrequency ablation of the cavotricuspid isthmus, but mapping and ablation of atypical flutter circuits may be challenging.(1) Entrainment mapping has been used in combination with activation mapping to define the mechanism of atypical atrial flutter. Here, we report a case where colour-coded three-dimensional (3D) entrainment mapping allowed us to accurately determine and visualize the 3D location of the reentrant circuit and to plan the ablation of a left atrial flutter without the need for activation mapping.
Resumo:
Incisional hernia is a common complication after liver transplantation. The current study evaluated incidence and risk factors for incisional hernia and compared laparoscopic and open hernia repair in terms of feasibility and outcome.
Resumo:
Injecting drug use (IDU) before and after liver transplantation (LT) is poorly described. The aim of this study was to quantify relapse and survival in this population and to describe the causes of mortality after LT.
Resumo:
QUESTIONS UNDER STUDY / PRINCIPLES: Interest groups advocate centre-specific outcome data as a useful tool for patients in choosing a hospital for their treatment and for decision-making by politicians and the insurance industry. Haematopoietic stem cell transplantation (HSCT) requires significant infrastructure and represents a cost-intensive procedure. It therefore qualifies as a prime target for such a policy. METHODS: We made use of the comprehensive database of the Swiss Blood Stem Cells Transplant Group (SBST) to evaluate potential use of mortality rates. Nine institutions reported a total of 4717 HSCT - 1427 allogeneic (30.3%), 3290 autologous (69.7%) - in 3808 patients between the years 1997 and 2008. Data were analysed for survival- and transplantation-related mortality (TRM) at day 100 and at 5 years. RESULTS: The data showed marked and significant differences between centres in unadjusted analyses. These differences were absent or marginal when the results were adjusted for disease, year of transplant and the EBMT risk score (a score incorporating patient age, disease stage, time interval between diagnosis and transplantation, and, for allogeneic transplants, donor type and donor-recipient gender combination) in a multivariable analysis. CONCLUSIONS: These data indicate comparable quality among centres in Switzerland. They show that comparison of crude centre-specific outcome data without adjustment for the patient mix may be misleading. Mandatory data collection and systematic review of all cases within a comprehensive quality management system might, in contrast, serve as a model to ascertain the quality of other cost-intensive therapies in Switzerland.
Resumo:
Stem cell transplantation has evolved as a promising experimental treatment approach for stroke. In this review, we address the major hurdles for successful translation from basic research into clinical applications and discuss possible strategies to overcome these issues. We summarize the results from present pre-clinical and clinical studies and focus on specific areas of current controversy and research: (i) the therapeutic time window for cell transplantation; (ii) the selection of patients likely to benefit from such a therapy; (iii) the optimal route of cell delivery to the ischemic brain; (iv) the most suitable cell types and sources; (v) the potential mechanisms of functional recovery after cell transplantation; and (vi) the development of imaging techniques to monitor cell therapy.
Resumo:
To determine the inter-patient variability of apparent diffusion coefficients (ADC) and concurrent micro-circulation contributions from diffusion-weighted MR imaging (DW-MRI) in renal allografts early after transplantation, and to obtain initial information on whether these measures are altered in histologically proven acute allograft rejection (AR).
Resumo:
To test the hypothesis that the lectin-like domain of tumor necrosis factor, mimicked by the TIP peptide, can improve lung function after unilateral orthotopic lung isotransplantation. Because of a lack of a specific treatment for ischemia reperfusion-mediated lung injury, accompanied by a disrupted barrier integrity and a dysfunctional alveolar liquid clearance, alternative therapies restoring these parameters after lung transplantation are required.
Resumo:
To report our initial experience with dual-energy computed-tomography (CT) cholangiography in potential donors for living-related liver transplantation.
Resumo:
Arterial pressure-based cardiac output monitors (APCOs) are increasingly used as alternatives to thermodilution. Validation of these evolving technologies in high-risk surgery is still ongoing. In liver transplantation, FloTrac-Vigileo (Edwards Lifesciences) has limited correlation with thermodilution, whereas LiDCO Plus (LiDCO Ltd.) has not been tested intraoperatively. Our goal was to directly compare the 2 proprietary APCO algorithms as alternatives to pulmonary artery catheter thermodilution in orthotopic liver transplantation (OLT). The cardiac index (CI) was measured simultaneously in 20 OLT patients at prospectively defined surgical landmarks with the LiDCO Plus monitor (CI(L)) and the FloTrac-Vigileo monitor (CI(V)). LiDCO Plus was calibrated according to the manufacturer's instructions. FloTrac-Vigileo did not require calibration. The reference CI was derived from pulmonary artery catheter intermittent thermodilution (CI(TD)). CI(V)-CI(TD) bias ranged from -1.38 (95% confidence interval = -2.02 to -0.75 L/minute/m(2), P = 0.02) to -2.51 L/minute/m(2) (95% confidence interval = -3.36 to -1.65 L/minute/m(2), P < 0.001), and CI(L)-CI(TD) bias ranged from -0.65 (95% confidence interval = -1.29 to -0.01 L/minute/m(2), P = 0.047) to -1.48 L/minute/m(2) (95% confidence interval = -2.37 to -0.60 L/minute/m(2), P < 0.01). For both APCOs, bias to CI(TD) was correlated with the systemic vascular resistance index, with a stronger dependence for FloTrac-Vigileo. The capability of the APCOs for tracking changes in CI(TD) was assessed with a 4-quadrant plot for directional changes and with receiver operating characteristic curves for specificity and sensitivity. The performance of both APCOs was poor in detecting increases and fair in detecting decreases in CI(TD). In conclusion, the calibrated and uncalibrated APCOs perform differently during OLT. Although the calibrated APCO is less influenced by changes in the systemic vascular resistance, neither device can be used interchangeably with thermodilution to monitor cardiac output during liver transplantation.
Resumo:
Obturator anterior hip dislocation is very rare. Poor results are described in patients with additional large transchondral fractures and treatment of these injuries remains challenging. Appropriate treatment recommendations are missing in the literature. This case report introduces surgical hip dislocation for osteochondral autograft transplantation with graft harvest from the nonweightbearing area of the head-neck junction as a salvage procedure in a large femoral head defect. We report the treatment and outcome of a 48-year-old man who sustained an anterior dislocation of the left hip after a motorcycle accident. After initial closed reduction in the emergency room, imaging analysis revealed a large osteochondral defect of the femoral head within the weightbearing area (10 × 20 mm, depth: 5 mm). The hip was exposed with a surgical hip dislocation using a trochanteric osteotomy. An osteochondral autograft was harvested from a nonweightbearing area of the femoral head and transferred into the defect. The patient was prospectively examined clinically and radiologically. Two years postoperatively, the patient was free of pain and complaints. The function of the injured hip was comparable to that of the contralateral, healthy hip and showed satisfying radiologic results. Surgical hip dislocation with a trochanteric flip osteotomy is a simple, one-step technique that allows full inspection of the hip to treat osteochondral femoral defects by osteochondral transplantation. The presented technique, used as a salvage procedure in a large femoral head defect, yielded good clinical and satisfying radiologic outcomes at the midterm.
Resumo:
To evaluate the feasibility of sodium 7-T magnetic resonance (MR) imaging in repaired tissue and native cartilage of patients after matrix-associated autologous chondrocyte transplantation (MACT) and compare results with delayed gadolinium-enhanced MR imaging of cartilage (dGEMRIC) at 3 T.
Resumo:
In cartilage repair, bioregenerative approaches using tissue engineering techniques have tried to achieve a close resemblance to hyaline cartilage, which might be visualized using advanced magnetic resonance imaging.
Resumo:
To use T2 and T2* mapping in patients after matrix-associated autologous chondrocyte transplantation (MACT) of the knee, and to compare and correlate both methodologies.
Resumo:
To evaluate the use of diffusion-weighted imaging (DWI) for the assessment of cartilage maturation in patients after matrix-associated autologous chondrocyte transplantation (MACT).