28 resultados para Totally Disconnected N-Dimensional Space

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Precise intraoperative assessment of the architecture of the biliary tree could reduce lesions to intra- or extrahepatic bile ducts. The aim of this study was to test feasibility of intraoperative three-dimensional imaging during liver resections. Isocentric C-arm fluoroscopy acquires three-dimensional images during a 190 degrees orbital rotation. The bile ducts were displayed three-dimensionally by realtime rotational projections or multiplanar reconstructions. The technique was established ex vivo in a preserved cadaveric human liver. Intraoperative three-dimensional cholangiography was performed in five patients with centrally located liver malignancies. Complete data acquisition in 3 patients depicted precise anatomical details of the architecture of the biliary tree up to third order divisions. Biliary imaging can be improved by the application of real-time intraoperative three-dimensional cholangiography. For the development of computer-aided navigation in hepatobiliary procedures, this technique could be an important prerequisite for defining landmarks of the liver in a three-dimensional space.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Let P be a probability distribution on q -dimensional space. The so-called Diaconis-Freedman effect means that for a fixed dimension d<

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The spine is a complex structure that provides motion in three directions: flexion and extension, lateral bending and axial rotation. So far, the investigation of the mechanical and kinematic behavior of the basic unit of the spine, a motion segment, is predominantly a domain of in vitro experiments on spinal loading simulators. Most existing approaches to measure spinal stiffness intraoperatively in an in vivo environment use a distractor. However, these concepts usually assume a planar loading and motion. The objective of our study was to develop and validate an apparatus, that allows to perform intraoperative in vivo measurements to determine both the applied force and the resulting motion in three dimensional space. The proposed setup combines force measurement with an instrumented distractor and motion tracking with an optoelectronic system. As the orientation of the applied force and the three dimensional motion is known, not only force-displacement, but also moment-angle relations could be determined. The validation was performed using three cadaveric lumbar ovine spines. The lateral bending stiffness of two motion segments per specimen was determined with the proposed concept and compared with the stiffness acquired on a spinal loading simulator which was considered to be gold standard. The mean values of the stiffness computed with the proposed concept were within a range of ±15% compared to data obtained with the spinal loading simulator under applied loads of less than 5 Nm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Software visualizations can provide a concise overview of a complex software system. Unfortunately, as software has no physical shape, there is no `natural' mapping of software to a two-dimensional space. As a consequence most visualizations tend to use a layout in which position and distance have no meaning, and consequently layout typically diverges from one visualization to another. We propose an approach to consistent layout for software visualization, called Software Cartography, in which the position of a software artifact reflects its vocabulary, and distance corresponds to similarity of vocabulary. We use Latent Semantic Indexing (LSI) to map software artifacts to a vector space, and then use Multidimensional Scaling (MDS) to map this vector space down to two dimensions. The resulting consistent layout allows us to develop a variety of thematic software maps that express very different aspects of software while making it easy to compare them. The approach is especially suitable for comparing views of evolving software, as the vocabulary of software artifacts tends to be stable over time. We present a prototype implementation of Software Cartography, and illustrate its use with practical examples from numerous open-source case studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Software visualizations can provide a concise overview of a complex software system. Unfortunately, since software has no physical shape, there is no “natural“ mapping of software to a two-dimensional space. As a consequence most visualizations tend to use a layout in which position and distance have no meaning, and consequently layout typical diverges from one visualization to another. We propose a consistent layout for software maps in which the position of a software artifact reflects its \emph{vocabulary}, and distance corresponds to similarity of vocabulary. We use Latent Semantic Indexing (LSI) to map software artifacts to a vector space, and then use Multidimensional Scaling (MDS) to map this vector space down to two dimensions. The resulting consistent layout allows us to develop a variety of thematic software maps that express very different aspects of software while making it easy to compare them. The approach is especially suitable for comparing views of evolving software, since the vocabulary of software artifacts tends to be stable over time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present the first-order corrected dynamics of fluid branes carrying higher-form charge by obtaining the general form of their equations of motion to pole-dipole order in the absence of external forces. Assuming linear response theory, we characterize the corresponding effective theory of stationary bent charged (an)isotropic fluid branes in terms of two sets of response coefficients, the Young modulus and the piezoelectric moduli. We subsequently find large classes of examples in gravity of this effective theory, by constructing stationary strained charged black brane solutions to first order in a derivative expansion. Using solution generating techniques and bent neutral black branes as a seed solution, we obtain a class of charged black brane geometries carrying smeared Maxwell charge in Einstein-Maxwell-dilaton gravity. In the specific case of ten-dimensional space-time we furthermore use T-duality to generate bent black branes with higher-form charge, including smeared D-branes of type II string theory. By subsequently measuring the bending moment and the electric dipole moment which these geometries acquire due to the strain, we uncover that their form is captured by classical electroelasticity theory. In particular, we find that the Young modulus and the piezoelectric moduli of our strained charged black brane solutions are parameterized by a total of 4 response coefficients, both for the isotropic as well as anisotropic cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An autonomous energy source within a human body is of key importance in the development of medical implants. This work deals with the modelling and the validation of an energy harvesting device which converts the myocardial contractions into electrical energy. The mechanism consists of a clockwork from a commercially available wrist watch. We developed a physical model which is able to predict the total amount of energy generated when applying an external excitation. For the validation of the model, a custom-made hexapod robot was used to accelerate the harvesting device along a given trajectory. We applied forward kinematics to determine the actual motion experienced by the harvesting device. The motion provides translational as well as rotational motion information for accurate simulations in three-dimensional space. The physical model could be successfully validated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Recent empirical work on the semantics of emotion terms across many different cultures and languages, using a theoretical componential approach, suggested that four dimensions are needed to parsimoniously describe the semantic space of the emotion domain as reflected in emotion terms (Fontaine, Scherer, Roesch, & Ellsworth, 2007; Fontaine, Scherer, & Soriano, 2013). In addition to valence, power, and arousal, a novelty dimension was discovered that mostly differentiated surprise from other emotions. Here, we further explore the existence and nature of the fourth dimension in semantic emotion space using a much larger and much more representative set of emotion terms. A group of 156 participants each rated 10 out of a set of 80 French emotion terms with respect to semantic meaning. The meaning of an emotion term was evaluated with respect to 68 emotion features representing the appraisal, action tendency, bodily reaction, expression, and feeling components of the emotion process. A principal component analysis confirmed the four-dimensional valence, power, arousal, and novelty structure. Moreover, this larger and much more representative set of emotion terms revealed that the novelty dimension not only differentiates surprise terms from other emotion terms, but also identifies substantial variation within the fear and joy emotion families.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The advent of imaging software programs has proved to be useful for diagnosis, treatment planning, and outcome measurement, but precision of 3-dimensional (3D) surgical simulation still needs to be tested. This study was conducted to determine whether the virtual surgery performed on 3D models constructed from cone-beam computed tomography (CBCT) can correctly simulate the actual surgical outcome and to validate the ability of this emerging technology to recreate the orthognathic surgery hard tissue movements in 3 translational and 3 rotational planes of space. MATERIALS AND METHODS: Construction of pre- and postsurgery 3D models from CBCTs of 14 patients who had combined maxillary advancement and mandibular setback surgery and 6 patients who had 1-piece maxillary advancement surgery was performed. The postsurgery and virtually simulated surgery 3D models were registered at the cranial base to quantify differences between simulated and actual surgery models. Hotelling t tests were used to assess the differences between simulated and actual surgical outcomes. RESULTS: For all anatomic regions of interest, there was no statistically significant difference between the simulated and the actual surgical models. The right lateral ramus was the only region that showed a statistically significant, but small difference when comparing 2- and 1-jaw surgeries. CONCLUSIONS: Virtual surgical methods were reliably reproduced. Oral surgery residents could benefit from virtual surgical training. Computer simulation has the potential to increase predictability in the operating room.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to identify the anatomy of pineal region venous complex using neuronavigation software when distorted by the presence of a space-occupying lesion and to describe the anatomical relationship between lesion and veins. Moreover we discuss its influence on the choice of the surgical strategy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three comprehensive one-dimensional simulators were used on the same PC to simulate the dynamics of different electrophoretic configurations, including two migrating hybrid boundaries, an isotachophoretic boundary and the zone electrophoretic separation of ten monovalent anions. Two simulators, SIMUL5 and GENTRANS, use a uniform grid, while SPRESSO uses a dynamic adaptive grid. The simulators differ in the way components are handled. SIMUL5 and SPRESSO feature one equation for all components, whereas GENTRANS is based on the use of separate modules for the different types of monovalent components, a module for multivalent components and a module for proteins. The code for multivalent components is executed more slowly compared to those for monovalent components. Furthermore, with SIMUL5, the computational time interval becomes smaller when it is operated with a reduced calculation space that features moving borders, whereas GENTRANS offers the possibility of using data smoothing (removal of negative concentrations), which can avoid numerical oscillations and speed up a simulation. SPRESSO with its adaptive grid could be employed to simulate the same configurations with smaller numbers of grid points and thus is faster in certain but not all cases. The data reveal that simulations featuring a large number of monovalent components distributed such that a high mesh is required throughout a large proportion of the column are fastest executed with GENTRANS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Calcaneonavicular coalitions (CNC) have been reported to be associated with anatomical aberrations of either the calcaneus and/or navicular bones. These morphological abnormalities may complicate accurate surgical resection. Three-dimensional analysis of spatial orientation and morphological characteristics may help in preoperative planning of resection. MATERIALS AND METHODS: Sixteen feet with a diagnosis of CNC were evaluated by means of 3-D CT modeling. Three angles were defined that were expressed in relation to one reproducible landmark (lateral border of the calcaneus): the dorsoplantar inclination, anteroposterior inclination, and socket angle. The depth and width of the coalitions were measured and calculated to obtain the estimated contact surface. Three-dimensional reconstructions of the calcanei served to evaluate the presence, distortion or absence of the anterior calcaneal facet and presence of a navicular beak. The interrater correlations were assessed in order to obtain values for the accuracy of the measurement methods. Sixteen normal feet were used as controls for comparison of the socket angle; anatomy of the anterior calcaneal facet and navicular beak as well. RESULTS: The dorsoplantar inclination angle averaged 50 degrees (+/-17), the anteroposterior inclination angle 64 degrees (+/-15), and the pathologic socket angle 98 degrees (+/-11). The average contact area was 156 mm(2). Ninety-four percent of all patients in the CNC group revealed a plantar navicular beak. In 50% of those patients the anterior calcaneal facet was replaced by the navicular portion and in 44% the facet was totally missing. In contrast, the socket angle in the control group averaged 77 degrees (+/-18), which was found to be statistically different than the CNC group (p = 0.0004). Only 25% of the patients in the control group had a plantar navicular beak. High, statistically significant interrater correlations were found for all measured angles. CONCLUSION: Computer-aided CT analysis and reconstructions help to determine the spatial orientations of CNC in space and provide useful information in order to anticipate morphological abnormalities of the calcaneus and navicular.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: In alveolar distraction, in cases of severe atrophy in particular, it is often difficult to perform osteotomies in order to make a transport segment in optimal size and shape. Moreover care must be taken, not to damage the closely locating anato- mical structures such as the maxillary sinus, the inferior alveolar nerve, and the roots of the neighboring teeth. For setting ideal osteotomy lines exactly, we have developed a CT-based preoperative planning tool. Methods: 3-dimensional visual reconstruction of the jaw is created from the preoperative CT scans (1.0-mm slice thick- ness). Using the image-processing software Mimics (Materialise, Yokohama, Japan), various procedures of virtual cutting are simulated first to determine optimal osteotomy lines and to design an ideal transport segment. After the computer planning, data from the virtual solid model are transferred to a rapid prototype model, and a guiding splint is made to transfer the planned surgical simulation to the actual surgery. Results: The method was used in a case of severe atrophy of the anterior maxilla. The patient had a large maxillary sinus requir- ing a precise osteotomy in this critical area. Using the splint allowing a 3-dimensional guidance, alveolar osteotomies were easily done to achieve a transport segment in sufficient dimen- sion as planned, and any perforation of the maxillary sinus could be avoided. Finally the alveolar distraction of 10mm has suc- cessfully been performed. Conclusion: The preoperative planning method and the guiding splint described here are useful in problematic cases requiring an extremely precise osteotomy due to lack of bony space.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reports on left-lateralized abnormalities of component P300 of event-related brain potentials (ERP) in schizophrenics typically did not vary task difficulties. We collected 16-channel ERP in 13 chronic, medicated schizophrenics (25±4.9 years) and 13 matched controls in a visual P300 paradigm with targets defined by one or two stimulus dimensions (C1: color; C2: color and tilt); subjects key-pressed to targets. The mean target-ERP map landscapes were assessed numerically by the locations of the positive and negative map-area centroids. The centroids' time-space trajectories were searched for the P300 microstate landscape defined by the positive centroid posterior of the negative centroid. At P300 microstate centre latencies in C1, patients' maps tended to a right shift of the positive centroid (p<0.10); in C2 the anterior centroid was more posterior (p<0.07) and the posterior (positive) centroid more anterior (p<0.03), but without leftright difference. Duration of P300 microstate in C2 was shorter in patients (232 vs 347 ms;p<0.03) and the latency of maximal strength of P300 microstate increased significantly in patients (C1: 459 vs 376 ms; C2: 585 vs 525 ms). In summary only the one-dimensional task C1 supported left-sided abnormalities; the two-dimensional task C2 produced abnormal P300 microstate map landscapes in schizophrenics, but no abnormal lateralization. Thus, information processing involved clearly aberrant neural populations in schizophrenics, different when processing one and two stimulus dimensions. The lack of lateralization in the two-dimensional task supported the view that left-temporal abnormality in schizophrenics is only one of several task-dependent aberrations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

27-Channel EEG potential map series were recorded from 12 normals with closed and open eyes. Intracerebral dipole model source locations in the frequency domain were computed. Eye opening (visual input) caused centralization (convergence and elevation) of the source locations of the seven frequency bands, indicative of generalized activity; especially, there was clear anteriorization of α-2 (10.5–12 Hz) and β-2 (18.5–21 Hz) sources (α-2 also to the left). Complexity of the map series' trajectories in state space (assessed by Global Dimensional Complexity and Global OMEGA Complexity) increased significantly with eye opening, indicative of more independent, parallel, active processes. Contrary to PET and fMRI, these results suggest that brain activity is more distributed and independent during visual input than after eye closing (when it is more localized and more posterior).