41 resultados para Torsional compression

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Previous studies on the influence of torsion and combined torsion-compression loading revealed a positive effect on the cell viability when a repetitive short-term torsion was applied at a physiological magnitude to intervertebral disc organ culture.1 However, after an extended period (8 hours) of combined torsion-compression loading, substantial cell death was detected in the nucleus pulposus (NP).2 In this follow-up study, we aimed to investigate the relationship, if any, between the duration of torsion applied to the intervertebral disc (IVD) and the level of NP cell viability. Materials and Methods Bovine caudal discs were harvested and cultured in a custom-built multiaxis dynamic loading bioreactor.2 Torsion (± 2 degrees) was applied to the samples at a frequency of 0.2 Hz. Torsion was applied for durations of 0, 1, 4, and 8 h/d, repeated over 7 days. After the last day of loading, disc tissue was dissected for analysis of cell viability and gene expression. Results Disc NP cell viability remained above 85% after torsional loading for 0, 1, or 4 h/d. Viability was statistical significantly reduced to below 70% when torsion was applied for 8 h/d (p = 0.03) (Table 1). The daily duration of torsional loading did not affect the AF cell viability (> 80% for all loading durations). The trend of collagen 2 gene upregulation and matrix metalloproteases 13 downregulation with an increasing duration of torsion was observed in both NP and AF (Fig. 1).Conclusion We have demonstrated that an extended duration of torsion could inhibit the survival of NP cells within the IVD in organ culture. Acknowledgments Funds from the Orthopedic Department of the Insel University Hospital of Bern and a private donation from Prof. Dr. Paul Heini, Spine Surgeon, Sonnenhof Clinic Bern were received to support this work. Disclosure of Interest None declared References References 1 Chan SC, Ferguson SJ, Wuertz K, Gantenbein-Ritter B. Biological response of the intervertebral disc to repetitive short-term cyclic torsion. Spine 2011;36(24):2021–2030 2 Chan SC, Walser J, Käppeli P, Shamsollahi MJ, Ferguson SJ, Gantenbein-Ritter B. Region specific response of intervertebral disc cells to complex dynamic loading: an organ culture study using a dynamic torsion-compression bioreactor. PLoS ONE 2013;8(8):e72489

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the ease of application of two-piece, graduated, compression systems for the treatment of venous ulcers. METHODS: Four kits used to provide limb compression in the management of venous ulcers were evaluated. These have been proven to be non-inferior to various types of bandages in clinical trials. The interface pressure exerted above the ankle by the under-stocking and the complete compression system and the force required to pull the over-stocking off were assessed in vitro. Ease of application of the four kits was evaluated in four sessions by five nurses who put stockings on their own legs in a blinded manner. They expressed their assessment of the stockings using a series of visual analogue scales (VASs). RESULTS: The Sigvaris Ulcer X((R)) kit provided a mean interface pressure of 46 mmHg and required a force in the range of 60-90 N to remove it. The Mediven((R)) ulcer kit exerted the same pressure but required force in the range of 150-190 N to remove it. Two kits (SurePress((R)) Comfort and VenoTrain((R)) Ulcertec) exerted a mean pressure of only 25 mmHg and needed a force in the range of 100-160 N to remove them. Nurses judged the Ulcer X and SurePress kits easiest to apply. Application of the VenoTrain kit was found slightly more difficult. The Mediven kit was judged to be difficult to use. CONCLUSIONS: Comparison of ease of application of compression-stocking kits in normal legs revealed marked differences between them. Only one system exerted a high pressure and was easy to apply. Direct comparison of these compression kits in leg-ulcer patients is required to assess whether our laboratory findings correlate with patient compliance and ulcer healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare the proportion and rate of healing, pain, and quality of life of low-strength medical compression stockings (MCS) with traditional bandages applied for the treatment of recalcitrant venous leg ulcers. METHODS: A single-center, randomized, open-label study was performed with consecutive patients. Sigvaris prototype MCS providing 15 mm Hg-25 mm Hg at the ankle were compared with multi-layer short-stretch bandages. In both groups, pads were placed above incompetent perforating veins in the ulcer area. The initial static pressure between the dressing-covered ulcer and the pad was 29 mm Hg and 49 mm Hg with MCS and bandages, respectively. Dynamic pressure measurements showed no difference. Compression was maintained day and night and changed every week. The primary endpoint was healing within 90 days. Secondary endpoints were healing within 180 days, time to healing, pain (weekly Likert scales), and monthly quality of life (ChronIc Venous Insufficiency Quality of Life [CIVIQ] questionnaire). RESULTS: Of 74 patients screened, 60 fulfilled the selection criteria and 55 completed the study; 28 in the MCS and 27 in the bandage group. Ulcers were recurrent (48%), long lasting (mean, 27 months), and large (mean, 13 cm2). All but one patient had deep venous reflux and/or incompetent perforating veins in addition to trunk varices. Characteristics of patients and ulcers were evenly distributed (exception: more edema in the MCS group; P = .019). Healing within 90 days was observed in 36% with MCS and in 48% with bandages (P = .350). Healing within 180 days was documented in 50% with MCS and in 67% with bandages (P = .210). Time to healing was identical. Pain scored 44 and 46 initially (on a scale in which 100 referred to maximum and 0 to no pain) and decreased within the first week to 20 and 28 in the MCS and bandage groups, respectively (P < .001 vs .010). Quality of life showed no difference between the treatment groups. In both groups, pain at 90 days had decreased by half, independent of completion of healing. Physical, social, and psychic impairment improved significantly in patients with healed ulcers only. CONCLUSION: Our study illustrates the difficulty of bringing large and long-standing venous ulcers to heal. The effect of compression with MCS was not different from that of compression with bandages. Both treatments alleviated pain promptly. Quality of life was improved only in patients whose ulcers had healed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose was to investigate the in vivo effects of unloading and compression on T1-Gd relaxation times in healthy articular knee cartilage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data gathering, either for event recognition or for monitoring applications is the primary intention for sensor network deployments. In many cases, data is acquired periodically and autonomously, and simply logged onto secondary storage (e.g. flash memory) either for delayed offline analysis or for on demand burst transfer. Moreover, operational data such as connectivity information, node and network state is typically kept as well. Naturally, measurement and/or connectivity logging comes at a cost. Space for doing so is limited. Finding a good representative model for the data and providing clever coding of information, thus data compression, may be a means to use the available space to its best. In this paper, we explore the design space for data compression for wireless sensor and mesh networks by profiling common, publicly available algorithms. Several goals such as a low overhead in terms of utilized memory and compression time as well as a decent compression ratio have to be well balanced in order to find a simple, yet effective compression scheme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Occupational leg symptoms are highly prevalent in the general population and impair the psychic state of health. We investigated hairdressers, a cohort exposed to prolonged standing during work, in a randomized crossover trial. We hypothesized that hairdressers wearing low-strength compression hosiery would benefit from less leg volume increase and discomfort. METHODS: One hundred and eight hairdressers were randomized to wear medical compression stockings (MCS; 15-20 mmHg) in a crossover study. The effect of MCS on symptoms and on lower leg volume was compared with no compression treatment. Symptoms were assessed with a comprehensive questionnaire, categorized using factor analysis with varimax rotation and correlated with leg volume changes. RESULTS: Wearing MCS reduced the symptom score for pain and feelings of swelling (range 0-4) by an average of 0.22 (12%, P < 0.001). Sleep disturbance, feeling of unattractive legs and depressiveness improved with MCS compared with no MCS. Subjects initially obliged to refrain from wearing stockings showed a significant decrease of pain and feelings of swelling as well (by 0.10 [6%], P = 0.015). Wearing MCS was associated with a decrease of lower leg volume by an average of 19 mL (P < 0.001), with preference in older hairdressers (P < 0.001). The effects of wearing MCS on symptoms and on leg volume were not correlated with each other. CONCLUSIONS: Individuals working in a standing profession experience leg pain, feelings of swelling, heaviness and various other disturbing feelings. These symptoms can be alleviated by wearing low-strength MCS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the analysis of the SI So rotational band contours of jet-cooled 5-methyl-2-hydroxypyrimidine (5M2HP), the enol form of deoxythymine. Unlike thymine, which exhibits a structureless spectrum, the vibronic spectrum of 5M2HP is well structured, allowing us to determine the rotational constants and the methyl group torsional barriers in the S-0 and S-1 states. The 0(0)(0), 6a(0)(1), 6b(0)(1), and 14(0)(1) band contours were measured at 900 MHz (0.03 cm(-1)) resolution using mass-specific two-color resonant two-photon ionization (2C-R2PI) spectroscopy. All four bands are polarized perpendicular to the pyrimidine plane (>90% c type), identifying the S-1 <- S-0 excitation of 5M2HP as a 1n pi* transition. All contours exhibit two methyl rotor subbands that arise from the lowest 5-methyl torsional states 0A '' and 1E ''. The S-0 and S-1 state torsional barriers were extracted from fits to the torsional subbands. The 3-fold barriers are V-3 '' = 13 cm(-1) and V3' = SI cm(-1); the 6-fold barrier contributions V-6 '' and V-6' are in the range of 2-3 cm(-1) and are positive in both states. The changes of A, B, and C rotational constants upon S-1 <- S-0 excitation were extracted from the contours and reflect an "anti-quinoidal" distortion. The 0(0)(0) contour can only be simulated if a 3 GHz Lorentzian line shape is included, which implies that the S-1(1n pi*) lifetime is similar to 55 ps. For the 6a(0)(1) and 6b(0)(1) bands, the Lorentzian component increases to 5.5 GHz, reflecting a lifetime decrease to similar to 30 ps. The short lifetimes are consistent with the absence of fluorescence from the 1n pi* state. Combining these measurements with the previous observation of efficient intersystem crossing (ISC) from the Si state to a long-lived T-1((3)n pi*) state that lies similar to 2200 cm(-1) below [S. Lobsiger, S. et al. Phys. Chem. Chem. Phys. 2010, 12, 5032] implies that the broadening arises from fast intersystem crossing with k(ISC) approximate to 2 x 10(10) s(-1). In comparison to 5-methylpyrimidine, the ISC rate is enhanced by at least 10 000 by the additional hydroxy group in position 2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Computer-based feedback systems for assessing the quality of cardiopulmonary resuscitation (CPR) are widely used these days. Recordings usually involve compression and ventilation dependent variables. Thorax compression depth, sufficient decompression and correct hand position are displayed but interpreted independently of one another. We aimed to generate a parameter, which represents all the combined relevant parameters of compression to provide a rapid assessment of the quality of chest compression-the effective compression ratio (ECR). METHODS: The following parameters were used to determine the ECR: compression depth, correct hand position, correct decompression and the proportion of time used for chest compressions compared to the total time spent on CPR. Based on the ERC guidelines, we calculated that guideline compliant CPR (30:2) has a minimum ECR of 0.79. To calculate the ECR, we expanded the previously described software solution. In order to demonstrate the usefulness of the new ECR-parameter, we first performed a PubMed search for studies that included correct compression and no-flow time, after which we calculated the new parameter, the ECR. RESULTS: The PubMed search revealed 9 trials. Calculated ECR values ranged between 0.03 (for basic life support [BLS] study, two helpers, no feedback) and 0.67 (BLS with feedback from the 6th minute). CONCLUSION: ECR enables rapid, meaningful assessment of CPR and simplifies the comparability of studies as well as the individual performance of trainees. The structure of the software solution allows it to be easily adapted to any manikin, CPR feedback devices and different resuscitation guidelines (e.g. ILCOR, ERC).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteotomies of the proximal femur and stable fixation of displaced femoral neck fractures are demanding operations. An LCP Paediatric Hip Plate was developed to make these operations safer and less demanding. The article focuses on the surgical technique and critically analyses the device.