174 resultados para Tomography, Spiral Computed

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present study, dose measurements have been conducted following examination of the maxilla and mandible with spiral computed tomography (CT). The measurements were carried out with 2 phantoms, a head and neck phantom and a full body phantom. The analysis of applied thermoluminescent dosimeters yielded radiation doses for organs and tissues in the head and neck region between 0.6 and 16.7 mGy when 40 axial slices and 120 kV/165 mAs were used as exposure parameters. The effective dose was calculated as 0.58 and 0.48 mSv in the maxilla and mandible, respectively. Tested methods for dose reduction showed a significant decrease of radiation dose from 40 to 65%. Based on these results, the mortality risk was estimated according to calculation models recommended by the Committee on the Biological Effects of Ionizing Radiations and by the International Commission on Radiological Protection. Both models resulted in similar values. The mortality risk ranges from 46.2 x 10.6 for 20-year-old men to 11.2 x 10(-6) for 65-year-old women. Using 2 methods of dose reduction, the mortality risk decreased by approximately 50 to 60% to 19.1 x 10(-6) for 20-year-old men and 5.5 x 10(-6) for 65-year-old women. It can be concluded that a CT scan of the maxillofacial complex causes a considerable radiation dose when compared with conventional radiographic examinations. Therefore, a careful indication for this imaging technique and dose reduction methods should be considered in daily practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Choline positron emission tomography (PET)/computed tomography (CT) is a currently used diagnostic tool in restaging prostate cancer (PCa) patients with increasing prostate-specific antigen (PSA) after either radical prostatectomy (RP) or external-beam radiation therapy (EBRT). However, no final recommendations have been made on the use of this modality for patient management.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Treatment guidelines recommend strong consideration of thrombolysis in patients with acute symptomatic pulmonary embolism (PE) that present with arterial hypotension or shock because of the high risk of death in this setting. For haemodynamically stable patients with PE, the categorization of risk for subgroups may assist with decision-making regarding PE therapy. Clinical models [e.g. Pulmonary Embolism Severity Index (PESI)] may accurately identify those at low risk of overall death in the first 3 months after the diagnosis of PE, and such patients might benefit from an abbreviated hospital stay or outpatient therapy. Though some evidence suggests that a subset of high-risk normotensive patients with PE may have a reasonable risk to benefit ratio for thrombolytic therapy, single markers of right ventricular dysfunction (e.g. echocardiography, spiral computed tomography, or brain natriuretic peptide testing) and myocardial injury (e.g. cardiac troponin T or I testing) have an insufficient positive predictive value for PE-specific mortality to drive decision-making toward such therapy. Recommendations for outpatient treatment or thrombolytic therapy for patients with PE necessitate further development of prognostic models and conduct of clinical trials that assess various treatment strategies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: To evaluate multislice spiral computed tomography (MSCT) and magnetic resonance imaging (MRI) findings in hanging and manual strangulation cases and compare them with forensic autopsy results. MATERIALS AND METHODS: Postmortem MSCT and MRI of nine persons who died from hanging or manual strangulation were performed. The neck findings were compared with those discovered during forensic autopsy. In addition, two living patients underwent imaging and clinical examination following severe manual strangulation and near-hanging, respectively. For evaluation, the findings were divided into "primary" (strangulation mark and subcutaneous desiccation (i.e., soft-tissue thinning as a result of tissue fluids being driven out by mechanical compression) in hanging, and subcutaneous and intramuscular hemorrhage in manual strangulation) and "collateral" signs. The Wilcoxon two-tailed test was used for statistical analysis of the lymph node and salivary gland findings. RESULTS: In hanging, the primary and most frequent collateral signs were revealed by imaging. In manual strangulation, the primary findings were accurately depicted, with the exception of one slight hemorrhage. Apart from a vocal cord hemorrhage, all frequent collateral signs could be diagnosed radiologically. Traumatic lymph node hemorrhage (P = 0.031) was found in all of the manual strangulation cases. CONCLUSION: MSCT and MRI revealed strangulation signs concordantly with forensic pathology findings. Imaging offers a great potential for the forensic examination of lesions due to strangulation in both clinical and postmortem settings.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE To compare EEG power spectra and LORETA-computed intracortical activity between Alzheimer's disease (AD) patients and healthy controls, and to correlate the results with cognitive performance in the AD group. METHODS Nineteen channel resting EEG was recorded in 21 mild to moderate AD patients and in 23 controls. Power spectra and intracortical LORETA tomography were computed in seven frequency bands and compared between groups. In the AD patients, the EEG results were correlated with cognitive performance (Mini Mental State Examination, MMSE). RESULTS AD patients showed increased power in EEG delta and theta frequency bands, and decreased power in alpha2, beta1, beta2 and beta3. LORETA specified that increases and decreases of power affected different cortical areas while largely sparing prefrontal cortex. Delta power correlated negatively and alpha1 power positively with the AD patients' MMSE scores; LORETA tomography localized these correlations in left temporo-parietal cortex. CONCLUSIONS The non-invasive EEG method of LORETA localized pathological cortical activity in our mild to moderate AD patients in agreement with the literature, and yielded striking correlations between EEG delta and alpha1 activity and MMSE scores in left temporo-parietal cortex. SIGNIFICANCE The present data support the hypothesis of an asymmetrical progression of the Alzheimer's disease.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

CONTEXT Radiolabelled choline positron emission tomography has changed the management of prostate cancer patients. However, new emerging radiopharmaceutical agents, like radiolabelled prostate specific membrane antigen, and new promising hybrid imaging will begin new challenges in the diagnostic field. OBJECTIVE The continuous evolution in nuclear medicine has led to the improvement in the detection of recurrent prostate cancer (PCa), particularly distant metastases. New horizons have been opened for radiolabelled choline positron emission tomography (PET)/computed tomography (CT) as a guide for salvage therapy or for the assessment of systemic therapies. In addition, new tracers and imaging tools have been recently tested, providing important information for the management of PCa patients. Herein we discuss: (1) the available evidence in literature on radiolabelled choline PET and their recent indications, (2) the role of alternative radiopharmaceutical agents, and (3) the advantages of a recent hybrid imaging device (PET/magnetic resonance imaging) in PCa. EVIDENCE ACQUISITION Data from recently published (2010-2015), original articles concerning the role of choline PET/CT, new emerging radiotracers, and a new imaging device are analysed. This review is reported according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. EVIDENCE SYNTHESIS In the restaging phase, the detection rate of choline PET varies between 4% and 97%, mainly depending on the site of recurrence and prostate-specific antigen levels. Both 68gallium (68Ga)-prostate specific membrane antigen and 18F-fluciclovine are shown to be more accurate in the detection of recurrent disease as compared with radiolabelled choline PET/CT. Particularly, Ga68-PSMA has a detection rate of 50% and 68%, respectively for prostate-specific antigen levels < 0.5ng/ml and 0.5-2ng/ml. Moreover, 68Ga- PSMA PET/magnetic resonance imaging demonstrated a particularly higher accuracy in detecting PCa than PET/CT. New tracers, such as radiolabelled bombesin or urokinase-type plasminogen activator receptor, are promising, but few data in clinical practice are available today. CONCLUSIONS Some limitations emerge from the published papers, both for radiolabelled choline PET/CT and also for new radiopharmaceutical agents. Efforts are still needed to enhance the impact of published data in the world of oncology, in particular when new radiopharmaceuticals are introduced into the clinical arena. PATIENT SUMMARY In the present review, the authors summarise the last evidences in clinical practice for the assessment of prostate cancer, by using nuclear medicine modalities, like positron emission tomography/computed tomography and positron emission tomography/magnetic resonance imaging.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Indications for the most frequently used imaging modalities in implant dentistry are proposed based on clinical need and biologic risk for the patient. To calculate the biologic risk, the authors carried out dose measurements. They demonstrated that the risk from a periapical radiograph is 20% of that from a panoramic radiograph. A panoramic radiograph and a series of 4 conventional tomographs of a single-tooth gap in the molar region carry 5% and 13% of the risk from computed tomography of the maxilla, respectively. Panoramic radiography is considered the standard radiographic examination for treatment planning of implant patients, because it imparts a low dose while giving the best radiographic survey. Periapical radiographs are used to elucidate details or to complete the findings obtained from the panoramic radiograph. Other radiographic methods, such as conventional film tomography or computed tomography, are applied only in special circumstances, film tomography being preferred for smaller regions of interest and computed tomography being justified for the complete maxilla or mandible when methods for dose reduction are followed. During follow-up, intraoral radiography is considered the standard radiographic examination, particularly for implants in the anterior region of the maxilla or for scientific studies. In patients requiring more than 5 periapical images, panoramic radiography is preferred.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In a technical development study approved by the institutional ethics committee, the feasibility of fast diffusion-weighted imaging as a replacement for conventional magnetic resonance (MR) imaging sequences (short inversion time inversion recovery [STIR] and T1-weighted spin echo [SE]) and positron emission tomography (PET)/computed tomography (CT) in the detection of skeletal metastases from prostate cancer was evaluated. MR imaging and carbon 11 ((11)C) choline PET/CT data from 11 consecutive prostate cancer patients with bone metastases were analyzed. Diffusion-weighted imaging appears to be equal, if not superior, to STIR and T1-weighted SE sequences and equally as effective as (11)C-choline PET/CT in detection of bone metastases in these patients. Diffusion-weighted imaging should be considered for further evaluation and comparisons with PET/CT for comprehensive whole-body staging and restaging in prostate and other cancers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE Positron emission tomography (PET)∕computed tomography (CT) measurements on small lesions are impaired by the partial volume effect, which is intrinsically tied to the point spread function of the actual imaging system, including the reconstruction algorithms. The variability resulting from different point spread functions hinders the assessment of quantitative measurements in clinical routine and especially degrades comparability within multicenter trials. To improve quantitative comparability there is a need for methods to match different PET∕CT systems through elimination of this systemic variability. Consequently, a new method was developed and tested that transforms the image of an object as produced by one tomograph to another image of the same object as it would have been seen by a different tomograph. The proposed new method, termed Transconvolution, compensates for differing imaging properties of different tomographs and particularly aims at quantitative comparability of PET∕CT in the context of multicenter trials. METHODS To solve the problem of image normalization, the theory of Transconvolution was mathematically established together with new methods to handle point spread functions of different PET∕CT systems. Knowing the point spread functions of two different imaging systems allows determining a Transconvolution function to convert one image into the other. This function is calculated by convolving one point spread function with the inverse of the other point spread function which, when adhering to certain boundary conditions such as the use of linear acquisition and image reconstruction methods, is a numerically accessible operation. For reliable measurement of such point spread functions characterizing different PET∕CT systems, a dedicated solid-state phantom incorporating (68)Ge∕(68)Ga filled spheres was developed. To iteratively determine and represent such point spread functions, exponential density functions in combination with a Gaussian distribution were introduced. Furthermore, simulation of a virtual PET system provided a standard imaging system with clearly defined properties to which the real PET systems were to be matched. A Hann window served as the modulation transfer function for the virtual PET. The Hann's apodization properties suppressed high spatial frequencies above a certain critical frequency, thereby fulfilling the above-mentioned boundary conditions. The determined point spread functions were subsequently used by the novel Transconvolution algorithm to match different PET∕CT systems onto the virtual PET system. Finally, the theoretically elaborated Transconvolution method was validated transforming phantom images acquired on two different PET systems to nearly identical data sets, as they would be imaged by the virtual PET system. RESULTS The proposed Transconvolution method matched different PET∕CT-systems for an improved and reproducible determination of a normalized activity concentration. The highest difference in measured activity concentration between the two different PET systems of 18.2% was found in spheres of 2 ml volume. Transconvolution reduced this difference down to 1.6%. In addition to reestablishing comparability the new method with its parameterization of point spread functions allowed a full characterization of imaging properties of the examined tomographs. CONCLUSIONS By matching different tomographs to a virtual standardized imaging system, Transconvolution opens a new comprehensive method for cross calibration in quantitative PET imaging. The use of a virtual PET system restores comparability between data sets from different PET systems by exerting a common, reproducible, and defined partial volume effect.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ophthalmologists typically acquire different image modalities to diagnose eye pathologies. They comprise e.g., Fundus photography, Optical Coherence Tomography (OCT), Computed Tomography (CT) and Magnetic Resonance Imaging (MRI). Yet, these images are often complementary and do express the same pathologies in a different way. Some pathologies are only visible in a particular modality. Thus, it is beneficial for the ophthalmologist to have these modalities fused into a single patient-specific model. The presented article’s goal is a fusion of Fundus photography with segmented MRI volumes. This adds information to MRI which was not visible before like vessels and the macula. This article’s contributions include automatic detection of the optic disc, the fovea, the optic axis and an automatic segmentation of the vitreous humor of the eye.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Positron emission tomography (PET)-computed tomography (CT) using [18F]-fluorodeoxyglucose (FDG) (FDG-PET/CT) is a valuable method for initial staging and follow up of patients with alveolar echinococcosis (AE). However, the cells responsible for FDG uptake have not been clearly identified. The main goal of our study was to evaluate the uptake of PET tracers by the cells involved in the host-parasite reaction around AE lesions as the first step to develop a specific PET tracer that would allow direct assessment of parasite viability in AE. Candidate molecules ([18F]-fluorotyrosine (FET), [18F]-fluorothymidine (FLT), and [18F]-fluorometylcholine (FMC), were compared to FDG by in vitro studies on human leukocytes and parasite vesicles. Our results confirmed that FDG was mainly consumed by immune cells and showed that FLT was the best candidate tracer for parasite metabolism. Indeed, parasite cells exhibited high uptake of FLT. We also performed PET/CT scans in mice infected intraperitoneally with E. multilocularis metacestodes. PET images showed no FDG or FLT uptake in parasitic lesions. This preliminary study assessed the metabolic activity of human leukocytes and AE cells using radiolabeling. Future studies could develop a specific PET tracer for AE lesions to improve lesion detection and echinococcosis treatment in patients. Our results demonstrated that a new animal model is needed for preclinical PET imaging to better mimic human hepatic and/or periparasitic metabolism.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

BACKGROUND: Current concepts of catheter ablation for atrial fibrillation (AF) commonly use three-dimensional (3D) reconstructions of the left atrium (LA) for orientation, catheter navigation, and ablation line placement. OBJECTIVES: The purpose of this study was to compare the 3D electroanatomic reconstruction (Carto) of the LA, pulmonary veins (PVs), and esophagus with the true anatomy displayed on multislice computed tomography (CT). METHODS: In this prospective study, 100 patients undergoing AF catheter ablation underwent contrast-enhanced spiral CT scan with barium swallow and subsequent multiplanar and 3D reconstructions. Using Carto, circumferential plus linear LA lesions were placed. The esophagus was tagged and integrated into the Carto map. RESULTS: Compared with the true anatomy on CT, the electroanatomic reconstruction accurately displayed the true distance between the lower PVs; the distances between left upper PV, left lower PV, right lower PV, and center of the esophagus; the longitudinal diameter of the encircling line around the funnel of the left PVs; and the length of the mitral isthmus line. Only the distances between the upper PVs, the distance between the right upper PV and esophagus, and the diameter of the right encircling line were significantly shorter on the electroanatomic reconstructions. Furthermore, electroanatomic tagging of the esophagus reliably visualized the true anatomic relationship to the LA. On multiple tagging and repeated CT scans, the LA and esophagus showed a stable anatomic relationship, without relevant sideward shifting of the esophagus. CONCLUSION: Electroanatomic reconstruction can display with high accuracy the true 3D anatomy of the LA and PVs in most of the regions of interest for AF catheter ablation. In addition, Carto was able to visualize the true anatomic relationship between the esophagus and LA. Both structures showed a stable anatomic relationship on Carto and CT without relevant sideward shifting of the esophagus.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The aim of this study was to obtain comprehensive data on clinical presentation, microbiology, computed tomography, surgical findings and histology in acute, sub-acute and chronic mastoiditis. We performed a prospective, observational study in children under 16 years of age presenting to our institution during the 2-year period beginning in April 2000. The children were examined and their condition treated in accordance with a standardized protocol elaborated by the paediatric, otolaryngology (ORL) and radiology departments. Thirty-eight patients were hospitalized (22 with acute mastoiditis, seven with sub-acute mastoiditis, nine with chronic mastoiditis). There were 30 complications present in 21 patients (55%). Streptococcus pyogenes was the most common pathogen (7/24 cases), followed by Streptococcus pneumoniae (4/24 cases). Mastoid surgery was performed in 29 patients. Histology of mastoid tissue revealed predominantly acute inflammation in two cases, mixed acute/chronic inflammation in 19 cases and predominantly chronic inflammation in seven cases. Radiologic data were evaluated retrospectively. Spiral, volume-based high-resolution (HR) computed tomography (CT) of the temporal bone had a sensitivity of 100%, specificity of 38%, positive predictive value (PPV) of 50% and negative predictive value (NPV) of 100% in detecting coalescence of mastoid trabeculae. Cranial CT with contrast had a sensitivity of 80%, specificity of 94%, PPV of 80% and NPV of 94% in identifying intra-cranial extension. Conclusion: histological evidence suggests that sub-acute/chronic infection underlies not only sub-acute and chronic mastoiditis, but most cases of acute mastoiditis as well. HR-CT of the temporal bone is effective in ruling out coalescence. Cranial CT is valuable in identifying intra-cranial extension. Cranial and HR-CT are recommended in the examination of children with mastoiditis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In addition to the increasingly significant role of multislice computed tomography in forensic pathology, the performance of whole-body computed tomography angiography provides outstanding results. In this case, we were able to detect multiple injuries of the parenchymal organs in the upper abdomen as well as lesions of the brain parenchyma and vasculature of the neck. The radiologic findings showed complete concordance with the autopsy and even supplemented the autopsy findings in areas that are difficult to access via a manual dissection (such as the vasculature of the neck). This case shows how minimally invasive computed tomography angiography can serve as an invaluable adjunct to the classic autopsy procedure.