3 resultados para Tolerances
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
PURPOSE The range of patient setup errors in six dimensions detected in clinical routine for cranial as well as for extracranial treatments, were analyzed while performing linear accelerator based stereotactic treatments with frameless patient setup systems. Additionally, the need for re-verification of the patient setup for situations where couch rotations are involved was analyzed for patients treated in the cranial region. METHODS AND MATERIALS A total of 2185 initial (i.e. after pre-positioning the patient with the infrared system but before image guidance) patient setup errors (1705 in the cranial and 480 in the extracranial region) obtained by using ExacTrac (BrainLAB AG, Feldkirchen, Germany) were analyzed. Additionally, the patient setup errors as a function of the couch rotation angle were obtained by analyzing 242 setup errors in the cranial region. Before the couch was rotated, the patient setup error was corrected at couch rotation angle 0° with the aid of image guidance and the six degrees of freedom (6DoF) couch. For both situations attainment rates for two different tolerances (tolerance A: ± 0.5mm, ± 0.5°; tolerance B: ± 1.0 mm, ± 1.0°) were calculated. RESULTS The mean (± one standard deviation) initial patient setup errors for the cranial cases were -0.24 ± 1.21°, -0.23 ± 0.91° and -0.03 ± 1.07° for the pitch, roll and couch rotation axes and 0.10 ± 1.17 mm, 0.10 ± 1.62 mm and 0.11 ± 1.29 mm for the lateral, longitudinal and vertical axes, respectively. Attainment rate (all six axes simultaneously) for tolerance A was 0.6% and 13.1% for tolerance B, respectively. For the extracranial cases the corresponding values were -0.21 ± 0.95°, -0.05 ± 1.08° and -0.14 ± 1.02° for the pitch, roll and couch rotation axes and 0.15 ± 1.77 mm, 0.62 ± 1.94 mm and -0.40 ± 2.15 mm for the lateral, longitudinal and vertical axes. Attainment rate (all six axes simultaneously) for tolerance A was 0.0% and 3.1% for tolerance B, respectively. After initial setup correction and rotation of the couch to treatment position a re-correction has to be performed in 77.4% of all cases to fulfill tolerance A and in 15.6% of all cases to fulfill tolerance B. CONCLUSION The analysis of the data shows that all six axes of a 6DoF couch are used extensively for patient setup in clinical routine. In order to fulfill high patient setup accuracies (e.g. for stereotactic treatments), a 6DoF couch is recommended. Moreover, re-verification of the patient setup after rotating the couch is required in clinical routine.
Resumo:
1. The morphologically complex taxon Cyclotella comensis Grunow had no clear relationship with environmental parameters in a study using sediment surface samples from the Swiss Alps. The morphological heterogeneity of the taxon was investigated by applying a principal component analysis (PCA) to 9000 presence/absence descriptions of valves from surface samples of six lakes from different altitudes (15 characteristics, 100 valves each lake). The PCA allowed the classification of six morphs, which differed mainly in size and length of striae. Photographs of the morphs are shown in this paper. 2. Sixty-eight sediment surface samples were analysed using these newly defined six morphs. Summer temperature explained a major part of the variance between the morphs as assessed by a redundancy analysis (RDA). Summer temperature optima and tolerances were estimated using weighted averaging. 3. The influence of the revised C. comensis taxonomy on the diatom inferred summer temperature of a high alpine lake is discussed in a multiproxy context for the past 800 years.
Resumo:
Chironomid-temperature inference models based on North American, European and combined surface sediment training sets were compared to assess the overall reliability of their predictions. Between 67 and 76 of the major chironomid taxa in each data set showed a unimodal response to July temperature, whereas between 5 and 22 of the common taxa showed a sigmoidal response. July temperature optima were highly correlated among the training sets, but the correlations for other taxon parameters such as tolerances and weighted averaging partial least squares (WA-PLS) and partial least squares (PLS) regression coefficients were much weaker. PLS, weighted averaging, WA-PLS, and the Modern Analogue Technique, all provided useful and reliable temperature inferences. Although jack-knifed error statistics suggested that two-component WA-PLS models had the highest predictive power, intercontinental tests suggested that other inference models performed better. The various models were able to provide good July temperature inferences, even where neither good nor close modern analogues for the fossil chironomid assemblages existed. When the models were applied to fossil Lateglacial assemblages from North America and Europe, the inferred rates and magnitude of July temperature changes varied among models. All models, however, revealed similar patterns of Lateglacial temperature change. Depending on the model used, the inferred Younger Dryas July temperature decrease ranged between 2.5 and 6°C.