72 resultados para Test methods
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
OBJECTIVES: Reactivation of latent tuberculosis (TB) in inflammatory bowel disease (IBD) patients treated with antitumor necrosis factor-alpha medication is a serious problem. Currently, TB screening includes chest x-rays and a tuberculin skin test (TST). The interferon-gamma release assay (IGRA) QuantiFERON-TB Gold In-Tube (QFT-G-IT) shows better specificity for diagnosing TB than the skin test. This study evaluates the two test methods among IBD patients. METHODS: Both TST and IGRA were performed on 212 subjects (114 Crohn's disease, 44 ulcerative colitis, 10 indeterminate colitis, 44 controls). RESULTS: Eighty-one percent of IBD patients were under immunosuppressive therapy; 71% of all subjects were vaccinated with Bacille Calmette Guérin; 18% of IBD patients and 43% of controls tested positive with the skin test (P < 0.0001). Vaccinated controls tested positive more often with the skin test (52%) than did vaccinated IBD patients (23%) (P = 0.011). Significantly fewer immunosuppressed patients tested positive with the skin test than did patients not receiving therapy (P = 0.007); 8% of patients tested positive with the QFT-G-IT test (14/168) compared to 9% (4/44) of controls. Test agreement was significantly higher in the controls (P = 0.044) compared to the IBD group. CONCLUSIONS: Agreement between the two test methods is poor in IBD patients. In contrast to the QFT-G-IT test, the TST is negatively influenced by immunosuppressive medication and vaccination status, and should thus be replaced by the IGRA for TB screening in immunosuppressed patients having IBD.
Resumo:
Summary The first part of this review examined ISO approval requirements and in vitro testing. In the second part, non-standardized test methods for composite materials are presented and discussed. Physical tests are primarily described. Analyses of surface gloss and alterations, as well as aging simulations of dental materials are presented. Again, the importance of laboratory tests in determining clinical outcomes is evaluated. Differences in the measurement protocols of the various testing institutes and how these differences can in?uence the results are also discussed. Because there is no standardization of test protocols, the values determined by different institutes cannot be directly compared. However, the ranking of the tested materials should be the same if a valid protocol is applied by different institutes. The modulus of elasticity, the expansion after water sorption, and the polishability of the material are all clinically relevant, whereas factors measured by other test protocols may have no clinical correlation. The handling properties of the materials are highly dependent on operators' preferences. Therefore, no standard values can be given.
Resumo:
Research suggests that mutans streptococci play an important role in cariogenesis in children but the usefulness of bacterial testing in risk assessment is unknown. Our objective was to summarize the literature assessing the association of mutans streptococci and dental caries in preschool children, (Pre)Medline (1966-2003), Embase (1980-2003), the Cochrane Register of Controlled Trials (2003, issue 3), and reference lists of included studies were searched. All abstracts found by the electronic searches (n = 981) were independently scrutinized by 2 reviewers. Minimal requirements for inclusion were assessment of preschool children without caries at baseline, reporting of mutans streptococci present in saliva or plaque at baseline and assessment of caries presence after a minimum of 6 months of follow-up. Participants' details, test methods, methodological characteristics and findings were extracted by one reviewer and cross-checked by another. Homogeneity was tested using chi2 tests. Results of plaque and saliva testing were pooled separately using a fixed effects model. Methodological quality of reports was low. Out of 9 studies included, data from 3 reports on plaque test assessment alone (n = 300) and from 4 reports on saliva test assessment alone (n = 451) were available for pooled analysis. The pooled risk ratio (95% CI) was 3.85 (2.48-5.96) in studies using plaque tests and 2.11 (1.47-3.02) in those using saliva testing. Presence of mutans streptococci, both in plaque or saliva of young caries-free children, appears to be associated with a considerable increase in caries risk. Lack of adjustment for potential confounders in the original studies, however, limits the extent to which interpretations for practice can be made.
Resumo:
BACKGROUND: Exertional oscillatory ventilation (EOV) in heart failure may potentiate the negative effects of low cardiac output and high ventilation on exercise performance. We hypothesized that the presence of EOV might, per se, influence exercise capacity as evaluated by maximal cardiopulmonary exercise test. METHODS AND RESULTS: We identified 78 severe chronic heart failure patient pairs with and without EOV. Patients were matched for sex, age and peak oxygen consumption (VO2). Patients with EOV showed, for the same peak VO2, a lower workload (WL) at peak (DeltaWatts=5.8+/-23.0, P=0.027), a less efficient ventilation (higher VE/VCO2 slope: 38.0+/-8.3 vs. 32.8+/-6.3, P<0.001), lower peak exercise tidal volume (1.49+/-0.36 L vs. 1.61+/-0.46 L, P=0.015) and higher peak respiratory rate (34+/-7/min vs. 31+/-6/min, P=0.002). In 33 patients, EOV disappeared during exercise, whereas in 45 patients EOV persisted. Fifty percent of EOV disappearing patients had an increase in the VO2/WL relationship after EOV regression, consistent with a more efficient oxygen delivery to muscles. No cardiopulmonary exercise test parameter was associated with the different behaviour of VO2/WL. CONCLUSION: The presence of EOV negatively influences exercise performance of chronic heart failure patients likely because of an increased cost of breathing. EOV disappearance during exercise is associated with a more efficient oxygen delivery in several cases.
Resumo:
OBJECTIVES: The objective of this systematic review was to assess the 5-year survival rates and incidences of complications associated with ceramic abutments and to compare them with those of metal abutments. METHODS: An electronic Medline search complemented by manual searching was conducted to identify randomized-controlled clinical trials, and prospective and retrospective studies providing information on ceramic and metal abutments with a mean follow-up time of at least 3 years. Patients had to have been examined clinically at the follow-up visit. Assessment of the identified studies and data abstraction was performed independently by three reviewers. Failure rates were analyzed using standard and random-effects Poisson regression models to obtain summary estimates of 5-year survival proportions. RESULTS: Twenty-nine clinical and 22 laboratory studies were selected from an initial yield of 7136 titles and data were extracted. The estimated 5-year survival rate of ceramic abutments was 99.1% [95% confidence interval (CI): 93.8-99.9%] and 97.4% (95% CI: 96-98.3%) for metal abutments. The estimated cumulative incidence of technical complications after 5 years was 6.9% (95% CI: 3.5-13.4%) for ceramic abutments and 15.9% (95% CI: 11.6-21.5%) for metal abutments. Abutment screw loosening was the most frequent technical problem, occurring at an estimated cumulative incidence after 5 years of 5.1% (95% CI: 3.3-7.7%). All-ceramic crowns supported by ceramic abutments exhibited similar annual fracture rates as metal-ceramic crowns supported by metal abutments. The cumulative incidence of biological complications after 5 years was estimated at 5.2% (95% CI: 0.4-52%) for ceramic and 7.7% (95% CI: 4.7-12.5%) for metal abutments. Esthetic complications tended to be more frequent at metal abutments. A meta-analysis of the laboratory data was impossible due to the non-standardized test methods of the studies included. CONCLUSION: The 5-year survival rates estimated from annual failure rates appeared to be similar for ceramic and metal abutments. The information included in this review did not provide evidence for differences of the technical and biological outcomes of ceramic and metal abutments. However, the information for ceramic abutments was limited in the number of studies and abutments analyzed as well as the accrued follow-up time. Standardized methods for the analysis of abutment strength are needed.
Resumo:
BACKGROUND While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC's ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.
Resumo:
BACKGROUND: Only few standardized apraxia scales are available and they do not cover all domains and semantic features of gesture production. Therefore, the objective of the present study was to evaluate the reliability and validity of a newly developed test of upper limb apraxia (TULIA), which is comprehensive and still short to administer. METHODS: The TULIA consists of 48 items including imitation and pantomime domain of non-symbolic (meaningless), intransitive (communicative) and transitive (tool related) gestures corresponding to 6 subtests. A 6-point scoring method (0-5) was used (score range 0-240). Performance was assessed by blinded raters based on videos in 133 stroke patients, 84 with left hemisphere damage (LHD) and 49 with right hemisphere damage (RHD), as well as 50 healthy subjects (HS). RESULTS: The clinimetric findings demonstrated mostly good to excellent internal consistency, inter- and intra-rater (test-retest) reliability, both at the level of the six subtests and at individual item level. Criterion validity was evaluated by confirming hypotheses based on the literature. Construct validity was demonstrated by a high correlation (r = 0.82) with the De Renzi-test. CONCLUSION: These results show that the TULIA is both a reliable and valid test to systematically assess gesture production. The test can be easily applied and is therefore useful for both research purposes and clinical practice.
Resumo:
Background: Visuoperceptual deficits in dementia are common and can reduce quality of life. Testing of visuoperceptual function is often confounded by impairments in other cognitive domains and motor dysfunction. We aimed to develop, pilot, and test a novel visuocognitive prototype test battery which addressed these issues, suitable for both clinical and functional imaging use. Methods: We recruited 23 participants (14 with dementia, 6 of whom had extrapyramidal motor features, and 9 age-matched controls). The novel Newcastle visual perception prototype battery (NEVIP-B-Prototype) included angle, color, face, motion and form perception tasks, and an adapted response system. It allows for individualized task difficulties. Participants were tested outside and inside the 3T functional magnetic resonance imaging (fMRI) scanner. Functional magnetic resonance imaging data were analyzed using SPM8. Results: All participants successfully completed the task inside and outside the scanner. Functional magnetic resonance imaging analysis showed activation regions corresponding well to the regional specializations of the visual association cortex. In both groups, there was significant activity in the ventral occipital-temporal region in the face and color tasks, whereas the motion task activated the V5 region. In the control group, the angle task activated the occipitoparietal cortex. Patients and controls showed similar levels of activation, except on the angle task for which occipitoparietal activation was lower in patients than controls. Conclusion: Distinct visuoperceptual functions can be tested in patients with dementia and extrapyramidal motor features when tests use individualized thresholds, adapted tasks, and specialized response systems.
Resumo:
Background Interferon-gamma release assays (IGRA) are more specific than the tuberculin skin test (TST) for the diagnosis of Mycobacterium tuberculosis infection. Data on sensitivity are controversial in HIV infection. Methods IGRA (T-SPOT.TB) was performed using lymphocytes stored within 6 months before culture-confirmed tuberculosis was diagnosed in HIV-infected individuals in the Swiss HIV Cohort Study. Results 64 individuals (69% males, 45% of non-white ethnicity, median age 35 years (interquartile range [IQR] 31-42), 28% with prior AIDS) were analysed. Median CD4 cell count was 223 cells/μl (IQR 103-339), HIV-RNA was 4.7 log10 copies/mL (IQR 4.3-5.2). T-SPOT.TB resulted positive in 25 patients (39%), negative in 18 (28%) and indeterminate in 21 (33%), corresponding to a sensitivity of 39% (95% CI 27-51%) if all test results were considered, and 58% (95% CI 43-74%) if indeterminate results were excluded. Sensitivity of IGRA was independent of CD4 cell count (p = 0.698). Among 44 individuals with available TST, 22 (50%) had a positive TST. Agreement between TST and IGRA was 57% (kappa = 0.14, p = 0.177), and in 34% (10/29) both tests were positive. Combining TST and IGRA (at least one test positive) resulted in an improved sensitivity of 67% (95% CI 52-81%). In multivariate analysis, older age was associated with negative results of TST and T-SPOT.TB (OR 3.07, 95% CI 1,22-7.74, p = 0.017, per 10 years older). Conclusions T-SPOT.TB and TST have similar sensitivity to detect latent TB in HIV-infected individuals. Combining TST and IGRA may help clinicians to better select HIV-infected individuals with latent tuberculosis who qualify for preventive treatment.
Tidal volume single breath washout of two tracer gases--a practical and promising lung function test
Resumo:
Background Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI), which can be assessed by washout tests of inert tracer gas. Using two tracer gases with unequal molar mass (MM) and diffusivity increases specificity for VI in different lung zones. Currently washout tests are underutilised due to the time and effort required for measurements. The aim of this study was to develop and validate a simple technique for a new tidal single breath washout test (SBW) of sulfur hexafluoride (SF6) and helium (He) using an ultrasonic flowmeter (USFM). Methods The tracer gas mixture contained 5% SF6 and 26.3% He, had similar total MM as air, and was applied for a single tidal breath in 13 healthy adults. The USFM measured MM, which was then plotted against expired volume. USFM and mass spectrometer signals were compared in six subjects performing three SBW. Repeatability and reproducibility of SBW, i.e., area under the MM curve (AUC), were determined in seven subjects performing three SBW 24 hours apart. Results USFM reliably measured MM during all SBW tests (n = 60). MM from USFM reflected SF6 and He washout patterns measured by mass spectrometer. USFM signals were highly associated with mass spectrometer signals, e.g., for MM, linear regression r-squared was 0.98. Intra-subject coefficient of variation of AUC was 6.8%, and coefficient of repeatability was 11.8%. Conclusion The USFM accurately measured relative changes in SF6 and He washout. SBW tests were repeatable and reproducible in healthy adults. We have developed a fast, reliable, and straightforward USFM based SBW method, which provides valid information on SF6 and He washout patterns during tidal breathing.
Resumo:
The aim of this in vitro study was to assess the agreement among four techniques used as gold standard for the validation of methods for occlusal caries detection. Sixty-five human permanent molars were selected and one site in each occlusal surface was chosen as the test site. The teeth were cut and prepared according to each technique: stereomicroscopy without coloring (1), dye enhancement with rhodamine B (2) and fuchsine/acetic light green (3), and semi-quantitative microradiography (4). Digital photographs from each prepared tooth were assessed by three examiners for caries extension. Weighted kappa, as well as Friedman's test with multiple comparisons, was performed to compare all techniques and verify statistical significant differences. Results: kappa values varied from 0.62 to 0.78, the latter being found by both dye enhancement methods. Friedman's test showed statistical significant difference (P < 0.001) and multiple comparison identified these differences among all techniques, except between both dye enhancement methods (rhodamine B and fuchsine/acetic light green). Cross-tabulation showed that the stereomicroscopy overscored the lesions. Both dye enhancement methods showed a good agreement, while stereomicroscopy overscored the lesions. Furthermore, the outcome of caries diagnostic tests may be influenced by the validation method applied. Dye enhancement methods seem to be reliable as gold standard methods.
Resumo:
This study evaluated the correlation between three strip-type, colorimetric tests and two laboratory methods with respect to the analysis of salivary buffering. The strip-type tests were saliva-check buffer, Dentobuff strip and CRT(®) Buffer test. The laboratory methods included Ericsson's laboratory method and a monotone acid/base titration to create a reference scale for the salivary titratable acidity. Additionally, defined buffer solutions were prepared and tested to simulate the carbonate, phosphate and protein buffer systems of saliva. The correlation between the methods was analysed by the Spearman's rank test. Disagreement was detected between buffering capacity values obtained with three strip-type tests that was more pronounced in case of saliva samples with medium and low buffering capacities. All strip-type tests were able to assign the hydrogencarbonate, di-hydrogenphosphate and 0.1% protein buffer solutions to the correct buffer categories. However, at 0.6% total protein concentrations, none of the test systems worked accurately. Improvements are necessary for strip-type tests because of certain disagreement with the Ericsson's laboratory method and dependence on the protein content of saliva.
Resumo:
OBJECTIVES: Fever is one of the most commonly seen symptoms in the pediatric emergency department. The objective of this study was to observe how the rapid testing for influenza virus impacts on the management of children with fever. METHODS: We performed a review of our pediatric emergency department records during the 2008/2009 annual influenza season. The BinaxNow Influenza A+B test was performed on patients with the following criteria: age 1.0 to 16.0 years, fever greater than 38.5 °C, fever of less than 96 hours' duration after the onset of clinical illness, clinical signs compatible with acute influenza, and nontoxic appearance. Additional laboratory tests were performed at the treating physician's discretion. RESULTS: The influenza rapid antigen test was performed in 192 children. One hundred nine (57%) were influenza positive, with the largest fraction (101 patients) positive for influenza A. The age distribution did not differ between children with negative and positive test results (mean, 5.3 vs. 5.1 years, not statistically significant). A larger number of diagnostic tests were performed in the group of influenza-negative patients. Twice as many complete blood counts, C-reactive protein determinations, lumbar punctures, and urinalyses were ordered in the latter group. CONCLUSIONS: Rapid diagnosis of influenza in the pediatric emergency department affects the management of febrile children as the confirmation of influenza virus infection decreases additional diagnostic tests ordered.
Resumo:
REASONS FOR PERFORMING STUDY: Insect bite hypersensitivity (IBH) is an IgE-mediated allergic dermatitis caused by bites of Culicoides and Simulium species, and improved means of diagnosis are required. OBJECTIVES: The cellular antigen simulation test (CAST) with C. nubeculosus and S. vittatum extracts was assessed in a population of IBH-affected and healthy horses. Variations in test results over a one year period and possible cross-reactivity between different insect extracts was studied. METHODS: A total of 314 mature horses were studied using the CAST. Influence of severity of clinical signs, gender and age were evaluated, and 32 horses were tested repeatedly over one year. The kappa reliability test was used to assess agreement of the test results with different insect extracts. RESULTS: Horses with IBH had significantly higher sLT release than controls with C. nubeculosus and S. vittatum. The highest diagnostic sensitivity and specificity levels were attained when using adult C. nubeculosus extracts with the CAST (78% and 97%, respectively), suggesting that most horses with IBH are sensitised against Culicoides allergens. A proportion of IBH-affected horses was found to be sensitised to allergens of Simulium spp. in addition to those of C. nubeculosus. The CAST with C. nubeculosus had positive and negative predictive values > or = 80% for a true prevalence of IBH of 12-52%. In the follow-up study, the proportion of IBH-affected horses with a positive test result ranged from 90% in November to 68% in March. Severity of clinical signs or age did not influence test results significantly. However, IBH-affected males achieved significantly more positive test results than IBH-affected females. CONCLUSIONS: The CAST with adult C. nubeculosus has high specificity and good sensitivity for diagnosis of IBH. Horses with IBH are mainly sensitised to Culicoides allergens, and some horses are additionally also sensitised to allergens in Simulium spp. POTENTIAL RELEVANCE: The CAST is likely to be a useful test for diagnosis of IBH, even allowing the identification of IBH-affected but asymptomatic horses. This test may also help in further characterisation of allergens involved in this condition.