21 resultados para Test Design

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction According to Lent and Lopez’ (2002) tripartite view of efficacy beliefs, members of a team form beliefs about the efficacy of their team partners. This other-efficacy belief can influence individual performance as shown by Dunlop, Beatty, and Beauchamp (2011) in their experimental study using manipulated performance feedback to alter other-efficacy beliefs. Participants holding favorable other-efficacy beliefs outperformed those with lower other--‐efficacy beliefs. Antecedents of such other-efficacy beliefs are amongst others perceptions regarding motivation and psychological factors of the partner (Jackson, Knapp, & Beauchamp, 2008). Overt self-talk could be interpreted as the manifestation of such motivational or psychological factors. In line with this assumption, in an experimental study using dubbed videos of the same segment of a tennis match, Van Raalte, Brewer, Cornelius, and Petitpas (2006) found that players were perceived more favorably (e.g., more concentrated, and of higher ability levels) when shown with dubbed positive self-talk as compared to dubbed negative or no dubbed self--‐talk. Objectives The aim of the study was to examine the possible effects of a confederate’s overt self-talk on participants’ other-efficacy beliefs and performance in a team setting. Method In a laboratory experiment (between-subjects, pre-post-test design, matched by pretest performance) 89 undergraduate students (female = 35, M = 20.81 years, SD = 2.34) participated in a golf putting task together with a confederate (same gender groups). Depending on the experimental condition (positive, negative, or no self-talk), the confederate commented his or her putts according to a self-talk script. Bogus performance feedback assured that the performance of the confederate was held constant. Performance was measured as the distance to the center of the target, other-efficacy by a questionnaire. Results The data collection has just finished and the results of repeated measures analyses of variance will be presented and discussed at the congress. We expect to find higher other-efficacy beliefs and better individual performance in the positive self-talk condition. References Dunlop, W.L., Beatty, D.J., & Beauchamp, M.R. (2011). Examining the influence of other-efficacy and self-efficacy on personal performance. Journal of Sport & Exercise Psychology, 33, 586-593. Jackson, B., Knapp, P., & Beauchamp, M.R. (2008). Origins and consequences of tripartite efficacy beliefs within elite athlete dyads. Journal of Sport and Exercise Psychology, 30, 512-540. Lent, R.W., & Lopez, F.G. (2002). Cognitive ties that bind: A tripartite view of efficacy beliefs in growth--‐promoting relationships. Journal of Social and Clinical Psychology, 21, 256-286. Van Raalte, J.L., Brewer, B.W, Cornelius, A.E., & Petitpas, A.J. (2006). Self-presentational effects of self-talk on perceptions of tennis players. Hellenic Journal of Psychology, 3, 134-149.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Autism has been associated with enhanced local processing on visual tasks. Originally, this was based on findings that individuals with autism exhibited peak performance on the block design test (BDT) from the Wechsler Intelligence Scales. In autism, the neurofunctional correlates of local bias on this test have not yet been established, although there is evidence of alterations in the early visual cortex. Functional MRI was used to analyze hemodynamic responses in the striate and extrastriate visual cortex during BDT performance and a color counting control task in subjects with autism compared to healthy controls. In autism, BDT processing was accompanied by low blood oxygenation level-dependent signal changes in the right ventral quadrant of V2. Findings indicate that, in autism, locally oriented processing of the BDT is associated with altered responses of angle and grating-selective neurons, that contribute to shape representation, figure-ground, and gestalt organization. The findings favor a low-level explanation of BDT performance in autism.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents the first analysis of the input impedance and radiation properties of a dipole antenna, placed on top of Fan 's three-dimensional electromagnetic bandgap (EBG) structure, (Applied Physics Letters, 1994) constructed using a high dielectric constant ceramic. The best position of the dipole on the EBG surface is determined following impedance and radiation pattern analyses. Based on this optimum configuration an integrated Schottky heterodyne detector was designed, manufactured and tested from 0.48 to 0.52 THz. The main antenna features were not degraded by the high dielectric constant substrate due to the use of the EBG approach. Measured radiation patterns are in good agreement with the predicted ones.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Percutaneous nephrolithotomy (PCNL) for the treatment of renal stones and other related renal diseases has proved its efficacy and has stood the test of time compared with open surgical methods and extracorporal shock wave lithotripsy. However, access to the collecting system of the kidney is not easy because the available intra-operative image modalities only provide a two dimensional view of the surgical scenario. With this lack of visual information, several punctures are often necessary which, increases the risk of renal bleeding, splanchnic, vascular or pulmonary injury, or damage to the collecting system which sometimes makes the continuation of the procedure impossible. In order to address this problem, this paper proposes a workflow for introduction of a stereotactic needle guidance system for PCNL procedures. An analysis of the imposed clinical requirements, and a instrument guidance approach to provide the physician with a more intuitive planning and visual guidance to access the collecting system of the kidney are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

SUMMARY The aim of this study was to evaluate the influence of surface roughness on surface hardness (Vickers; VHN), elastic modulus (EM), and flexural strength (FLS) of two computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic materials. One hundred sixty-two samples of VITABLOCS Mark II (VMII) and 162 samples of IPS Empress CAD (IPS) were ground according to six standardized protocols producing decreasing surface roughnesses (n=27/group): grinding with 1) silicon carbide (SiC) paper #80, 2) SiC paper #120, 3) SiC paper #220, 4) SiC paper #320, 5) SiC paper #500, and 6) SiC paper #1000. Surface roughness (Ra/Rz) was measured with a surface roughness meter, VHN and EM with a hardness indentation device, and FLS with a three-point bending test. To test for a correlation between surface roughness (Ra/Rz) and VHN, EM, or FLS, Spearman rank correlation coefficients were calculated. The decrease in surface roughness led to an increase in VHN from (VMII/IPS; medians) 263.7/256.5 VHN to 646.8/601.5 VHN, an increase in EM from 45.4/41.0 GPa to 66.8/58.4 GPa, and an increase in FLS from 49.5/44.3 MPa to 73.0/97.2 MPa. For both ceramic materials, Spearman rank correlation coefficients showed a strong negative correlation between surface roughness (Ra/Rz) and VHN or EM and a moderate negative correlation between Ra/Rz and FLS. In conclusion, a decrease in surface roughness generally improved the mechanical properties of the CAD/CAM ceramic materials tested. However, FLS was less influenced by surface roughness than expected.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Autism is a chronic pervasive neurodevelopmental disorder characterized by the early onset of social and communicative impairments as well as restricted, ritualized, stereotypic behavior. The endophenotype of autism includes neuropsychological deficits, for instance a lack of "Theory of Mind" and problems recognizing facial affect. In this study, we report the development and evaluation of a computer-based program to teach and test the ability to identify basic facially expressed emotions. 10 adolescent or adult subjects with high-functioning autism or Asperger-syndrome were included in the investigation. A priori the facial affect recognition test had shown good psychometric properties in a normative sample (internal consistency: rtt=.91-.95; retest reliability: rtt=.89-.92). In a prepost design, one half of the sample was randomly assigned to receive computer treatment while the other half of the sample served as control group. The training was conducted for five weeks, consisting of two hours training a week. The trained individuals improved significantly on the affect recognition task, but not on any other measure. Results support the usefulness of the program to teach the detection of facial affect. However, the improvement found is limited to a circumscribed area of social-communicative function and generalization is not ensured.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Users of cochlear implant systems, that is, of auditory aids which stimulate the auditory nerve at the cochlea electrically, often complain about poor speech understanding in noisy environments. Despite the proven advantages of multimicrophone directional noise reduction systems for conventional hearing aids, only one major manufacturer has so far implemented such a system in a product, presumably because of the added power consumption and size. We present a physically small (intermicrophone distance 7 mm) and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. Supporting algorithms, which allow the adjustment of the opening angle and the maximum noise suppression, are proposed and evaluated. A portable real-time device for test in real acoustic environments is presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The STAndards for Reporting studies of Diagnostic accuracy (STARD) for investigators and editors and the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) for reviewers and readers offer guidelines for the quality and reporting of test accuracy studies. These guidelines address and propose some solutions to two major threats to validity: spectrum bias and test review bias. STUDY DESIGN AND SETTING: Using a clinical example, we demonstrate that these solutions fail and propose an alternative solution that concomitantly addresses both sources of bias. We also derive formulas that prove the generality of our arguments. RESULTS: A logical extension of our ideas is to extend STARD item 23 by adding a requirement for multivariable statistical adjustment using information collected in QUADAS items 1, 2, and 12 and STARD items 3-5, 11, 15, and 18. CONCLUSION: We recommend reporting not only variation of diagnostic accuracy across subgroups (STARD item 23) but also the effects of the multivariable adjustments on test performance. We also suggest that the QUADAS be supplemented by an item addressing the appropriateness of statistical methods, in particular whether multivariable adjustments have been included in the analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although the nature of the blood groups A and B has been comprehensively studied for a long time, it is still unclear as to what exactly is the epitope that is recognized by antibodies having AB specificity, i.e. monoclonal and polyclonal antibodies which are capable of interacting equally well with the antigens GalNAcalpha 1-3(Fucalpha 1-2)Gal (A trisaccharide) and Galalpha 1-3(Fucalpha 1-2)Gal (B trisaccharide), but do not react with their common fragment Fucalpha 1-2Gal. We have supposed that besides Fucalpha 1-2Gal, A and B antigens have one more shared epitope. The trisaccharides A and B are practically identical from the conformational point of view, the only difference being situated at position 2 of Galalpha residue, i.e. trisaccharide A has a NHAc group, whereas trisaccharide B has a hydroxyl group (see formulas). We have hypothesized that the AB-epitope should be situated in the part of the molecule that is opposite to the NHAc group of GalNAc residue. In order to test this hypothesis we have synthesized a polymeric conjugate in such a way that de-N-acetylated A-trisaccharide is attached to a polymer via the nitrogen in position C-2 of the galactosamine residue. In this conjugate the supposed AB-epitope should be maximally accessible for antibodies from the solution, whereas the discrimination site of antigens A and B by the antibodies should be maximally hidden due to the close proximity of the polymer. Interaction with several anti-AB monoclonal antibodies revealed that a part of them really interacted with the synthetic AB-glycotope, thus confirming our hypothesis. Moreover, similar antibodies were revealed in the blood of healthy blood group 0 donors. Analysis of spatial models was performed in addition to identify the hydroxyl groups of Fuc, Galalpha, and Galbeta residues, which are particularly involved in the composition of the AB-glycotope.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES Optical scanners combined with computer-aided design and computer-aided manufacturing (CAD/CAM) technology provide high accuracy in the fabrication of titanium (TIT) and zirconium dioxide (ZrO) bars. The aim of this study was to compare the precision of fit of CAD/CAM TIT bars produced with a photogrammetric and a laser scanner. METHODS Twenty rigid CAD/CAM bars were fabricated on one single edentulous master cast with 6 implants in the positions of the second premolars, canines and central incisors. A photogrammetric scanner (P) provided digitized data for TIT-P (n=5) while a laser scanner (L) was used for TIT-L (n=5). The control groups consisted of soldered gold bars (gold, n=5) and ZrO-P with similar bar design. Median vertical distance between implant and bar platforms from non-tightened implants (one-screw test) was calculated from mesial, buccal and distal scanning electron microscope measurements. RESULTS Vertical microgaps were not significantly different between TIT-P (median 16μm; 95% CI 10-27μm) and TIT-L (25μm; 13-32μm). Gold (49μm; 12-69μm) had higher values than TIT-P (p=0.001) and TIT-L (p=0.008), while ZrO-P (35μm; 17-55μm) exhibited higher values than TIT-P (p=0.023). Misfit values increased in all groups from implant position 23 (3 units) to 15 (10 units), while in gold and TIT-P values decreased from implant 11 toward the most distal implant 15. SIGNIFICANCE CAD/CAM titanium bars showed high precision of fit using photogrammetric and laser scanners. In comparison, the misfit of ZrO bars (CAM/CAM, photogrammetric scanner) and soldered gold bars was statistically higher but values were clinically acceptable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In aviary systems for laying hens, it is important to provide suitable nest access platforms in front of the nests, allowing hens to reach and explore each of the nests easily. This access platform is needed to achieve good nest acceptance by the hens and thereby prevent mislaid eggs. In the present experiment, the behavior of hens using 2 different nest access platforms, a plastic grid and 2 wooden perches, was examined. Furthermore, the nests were placed on both sides of the aviary rack (corridor side and outdoor side), either integrated into the aviary rack itself (integrated nest; IN) or placed on the walls of the pens (wall nest; WN), resulting in a 2 × 2 factorial design Four thousand five hundred white laying hens were housed in 20 test pens. The eggs in the nests and mislaid eggs were collected daily, and the behavior of hens on the nest accesses was filmed during wk 25 and 26, using focal observation and scan sampling methods. More balancing, body contact, and agonistic interactions were expected for nests with perches, whereas more walking and nest inspections were expected for nests with grids. There were more mislaid eggs and balancing found in pens equipped with nests with wooden perches. More agonistic interactions and balancing, less standing, and a longer duration of nest inspection were found with the WN compared with the IN. Interactions between platform design and position of the nests were found for duration of nest visits, body contact, and walking, with the highest amount for WN equipped with plastic grids. Nests on the corridor side were favored by the hens. Nest-related behaviors, such as nest inspection, standing, and walking, decreased over time as did the number of hens on the nest accesses, whereas sitting increased. These results indicate that the hens had more difficulties in gripping the perches as designed. The lower number of hens on the nest access platforms in front of IN may be due to a better distribution around nests and tier changes within the aviary rack. Based on these results, grids rather than perches provide for improved nesting behavior.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE Group B streptococci (GBS) may lead to early onset neonatal sepsis with severe morbidity and mortality of newborns. Intrapartum detection of GBS is needed. The objective was to compare a PCR-based test performed in the laboratory versus labor ward. STUDY DESIGN 300 patients were included prospectively. In phase I, swabs were analyzed by selective culture and rapid PCR in the laboratory. In phase II, swabs were analyzed accordingly, but the PCR test was conducted in labor ward. Test performances were analyzed and compared. RESULTS In phase I the rapid PCR test had a sensitivity of 85.71% and a specificity of 95.9%. The GBS colonization rate was 18.67%. Overall 8.5% of the PCR results were invalid. In phase II the PCR test showed a sensitivity of 85.71% and a specificity of 95.65%. The GBS colonization rate was 23.3%. Overall 23.5% of swabs tested with PCR were invalid. Initiation of specific, short 2-hour training for operating personnel in the labor ward reduced the invalid test rate to 13.4%. CONCLUSION The rapid PCR-based test yields adequate results to identify GBS colonization when performed in labor ward. In order to reduce the number of invalid tests a short training period is needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Impaired manual dexterity is frequent and disabling in patients with multiple sclerosis (MS). Therefore, convenient, quick and validated tests for manual dexterity in MS patients are needed. OBJECTIVE: The aim of this study was to validate the Coin Rotation task (CRT) to examine manual dexterity in patients with MS. DESIGN: Cross-sectional study. METHODS: 101 outpatients with MS were assessed with the CRT, the Expanded Disability Status Scale (EDSS), the Scale for the assessment and rating of ataxia (SARA), the Modified Ashworth Scale (MAS), and their muscle strength and sensory deficits of the hands were noted. Concurrent validity and diagnostic accuracy of the CRT were determined by comparison with the Nine Hole Peg Test (9HPT). Construct validity was determined by comparison with a valid dexterity questionnaire. Multiple regression analysis was done to explore correlations of the CRT with the EDSS, SARA, MAS, muscle strength and sensory deficits. RESULTS: The CRT correlated significantly with the 9HPT (r=.73, p<.0001) indicating good concurrent validity. The cut-off values for the CRT relative to the 9HPT were 18.75 seconds for the dominant (sensitivity: 81.5%; specificity 80.0%) and 19.25 seconds for the non-dominant hand (sensitivity: 90.3%; specificity: 81.8%) demonstrating good diagnostic accuracy. Furthermore, the CRT correlated significantly with the dexterity questionnaire (r=-.49, p<.0001) indicating moderate construct validity. Multiple regression analyses revealed that the EDSS was the strongest predictor for impaired dexterity. LIMITATIONS: Mostly relapsing-remitting MS patients with an EDSS up to 7 were examined. CONCLUSIONS: This study validates the CRT as a test that can be used easily and quickly to evaluate manual dexterity in patients with MS.