3 resultados para TUNING RANGE
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
A new series of cationic dinuclear arene ruthenium complexes bridged by three thiophenolato ligands, [(η6-arene)2Ru2(μ2-SR)3]+ with arene = indane, R = met: 1 (met = 4-methylphenyl); R = mco: 4 (mco = 4-methylcoumarin-7-yl); arene = biphenyl, R = met: 2; R = mco: 5; arene = 1,2,3,4-tetrahydronaphthalene, R = met: 3; R = mco: 6, have been prepared from the reaction of the neutral precursor [(η6-arene)Ru(μ2-Cl)Cl]2 and the corresponding thiophenol RSH. All cationic complexes have been isolated as chloride salts and fully characterized by spectroscopic and analytical methods. The molecular structure of 1, solved by X-ray structure analysis of a single crystal of the chloride salt, shows the two ruthenium atoms adopting a pseudo-octahedral geometry without metal–metal bond in accordance with the noble gas rule. All complexes are stable in H2O at 37 °C, but only 1 remains soluble in a 100 mM aqueous NaCl solution, while significant percentages (30–60 %) of 2–6 precipitate as chloride salts under these conditions. The 4-methylphenylthiolato complexes (R = met) are highly cytotoxic towards human ovarian cancer cells, the IC50 values being in the sub-micromolar range, while the 4-methylcoumarin-7-yl thiolato complexes (R = mco) are only slightly cytotoxic. Complexes 1 and 3 show the highest in vitro anticancer activity with IC50 values inferior to 0.06 μM for the A2780 cell line. The results demonstrate that the arene ligand is an important parameter that should be more systematically evaluated when designing new half-sandwich organometallic complexes.
Resumo:
Sensitivity to spatial and temporal patterns is a fundamental aspect of vision. Herein, we investigated this sensitivity in adult zebrafish for a wide range of spatial (0.014 to 0.511 cycles/degree [c/d]) and temporal frequencies (0.025 to 6 cycles/s) to better understand their visual system. Measurements were performed at photopic (1.8 log cd m(-2)) and scotopic (-4.5 log cd m(-2)) light levels to assess the optokinetic response (OKR). The resulting spatiotemporal contrast sensitivity (CS) functions revealed that the OKR of zebrafish is tuned to spatial frequency and speed but not to temporal frequencies. Thereby, optimal test parameters for CS measurements were identified. At photopic light levels, a spatial frequency of 0.116 ± 0.01 c/d (mean ± SD) and a grating speed of 8.42 ± 2.15 degrees/second (d/s) was ideal; at scotopic light levels, these values were 0.110 ± 0.02 c/d and 5.45 ± 1.31 d/s, respectively. This study allows to better characterize zebrafish mutants with altered vision and to distinguish between defects of rod and cone photoreceptors as measurements were performed under different light conditions.
Resumo:
A medical cyclotron accelerating H- ions to 18 MeV is in operation at the Bern University Hospital (Inselspital). It is the commercial IBA 18/18 cyclotron equipped with a specifically conceived 6 m long external beam line ending in a separate bunker. This feature is unique for a hospital-based facility and makes it possible to conduct routine radioisotope production for PET diagnostics in parallel with multidisciplinary research activities, among which are novel particle detectors, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. Several of these activities, such as radiobiology experiments for example, require low current beams down to the pA range, while medical cyclotrons are designed for high current operation above 10 μA. In this paper, we present the first results on the low current performance of a PET medical cyclotron obtained by ion source, radio-frequency and main coil tuning. With this method, stable beam currents down to (1.5+/- 0.5 ) pA were obtained and measured with a high-sensitivity Faraday cup located at the end of the beam transport line.