58 resultados para TIPS-pentacene

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The treatment of proximal humerus fractures in patients with poor bone quality remains a challenge in trauma surgery. Augmentation with polymethylmethacrylate (PMMA) cement is a possible method to strengthen the implant anchorage in osteoporotic bone and to avoid loss of reduction and reduce the cut-out risk. The polymerisation of PMMA during cement setting leads, however, to an exothermic reaction and the development of supraphysiological temperatures may harm the bone and cartilage. This study addresses the issue of heat development during augmentation of subchondrally placed proximal humerus plate screws with PMMA and the possible risk of bone and cartilage necrosis and apoptosis. METHODS Seven fresh frozen humeri from geriatric female donors were instrumented with the proximal humerus interlocking system (PHILOS) plate and placed in a 37°C water bath. Thereafter, four proximal perforated screws were augmented with 0.5 ml PMMA each. During augmentation, the temperatures in the subchondral bone and on the articular surface were recorded with K-type thermocouples. The measured temperatures were compared to threshold values for necrosis and apoptosis of bone and cartilage reported in the literature. RESULTS The heat development was highest around the augmented tips of the perforated screws and diminished with growing distance from the cement cloud. The highest temperature recorded in the subchondral bone reached 43.5°C and the longest exposure time above 42°C was 86s. The highest temperature measured on the articular surface amounted to 38.6°C and the longest exposure time above 38°C was 5 min and 32s. CONCLUSION The study shows that augmentation of the proximal screws of the PHILOS plate with PMMA leads to a locally limited development of supraphysiological temperatures in the cement cloud and closely around it. The critical threshold values for necrosis and apoptosis of cartilage and subchondral bone reported in the literature, however, are not reached. In order to avoid cement extravasation, special care should be taken in detecting perforations or intra-articular cracks in the humeral head.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The robotic approach in thoracic surgery has rapidly gained popularity in recent years. As with the introduction of any new technology, this warrants not only adaptation of the operative technique itself, but also the evolution of appropriate troubleshooting strategies. A selected number of helpful tips and technical procedural manoeuvres have been compiled to prevent intraoperative problems, as well as to overcome challenging situations that can arise during robotic lobectomies. In robotic surgery, as opposed to open surgery or video-assisted thoracic surgery, these tips serve an important purpose for the operating surgeon, as well as the entire surgical team involved in the procedure. All the assembled recommendations have proved their effectiveness and have been successfully used by the authors in many procedures. Furthermore, these manoeuvres have been found to be of great importance in the training and proctoring of thoracic surgeons, fellows and residents (bed-side assistants). This guide of clearly arranged tips and troubleshooting strategies offers surgeons a useful tool to overcome difficult situations in robotic lobectomy and preferably improve the reproducibility and safety of their procedures.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Objectives: To investigate the influence of protein incorporation on the resistance of biomimetic calcium-phosphate coatings to the shear forces that are generated during implant insertion. Materials and Methods: Thirty-eight standard (5 x 13 mm) Osseotite((R)) implants were coated biomimetically with a layer of calcium phosphate, which either lacked or bore a co-precipitated (incorporated) depot of the model protein bovine serum albumin (BSA). The coated implants were inserted into either artificial bone (n=18) or the explanted mandibles of adult pigs (n=12). The former set-up was established for the measurement of torque and of coating losses during the insertion process. The latter set-up was established for the histological and histomorphometric analysis of the fate of the coatings after implantation. Results: BSA-bearing coatings had higher mean torque values than did those that bore no protein depot. During the insertion process, less material was lost from the former than from the latter type of coating. The histological and histomorphometric analysis revealed fragments of material to be sheared off from both types of coating at vulnerable points, namely, at the tips of the threads. The sheared-off fragments were retained within the peri-implant space. Conclusion: The incorporation of a protein into a biomimetically prepared calcium-phosphate coating increases its resistance to the shear forces that are generated during implant insertion. In a clinical setting, the incorporated protein would be an osteogenic agent, whose osteoinductive potential would not be compromised by the shearing off of coating material, and the osteoconductivity of an exposed implant surface would not be less than that of a coated one. To cite this article: Hägi TT, Enggist L, Michel D, Ferguson SJ, Liu Y, Hunziker EB. Mechanical insertion properties of calcium-phosphate implant coatings. Clin. Oral Impl. Res. xx, 2010; 000-000. doi: 10.1111/j.1600-0501.2010.01916.x.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The optical properties of a match-like plasmonic nanostructure are numerically investigated using full-wave finite-difference time-domain analysis in conjunction with dispersive material models. This work is mainly motivated by the developed technique enabling reproducible fabrication of nanomatch structures as well as the growing applications that utilize the localized field enhancement in plasmonic nanostructures. Our research revealed that due to the pronounced field enhancement and larger resonance tunabilities, some nanomatch topologies show potentials for various applications in the field of, e.g., sensing as well as a novel scheme for highly reproducible tips in scanning near field optical microscopy, among others. Despite the additional degrees of freedom that are offered by the composite nature of the proposed nanomatch topology, the paper also reflects on a fundamental complication intrinsic to the material interfaces especially in the nanoscale: stoichiometric mixing. We conclude that the specificity in material modeling will become a significant issue in future research on functionalized composite nanostructures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There are conflicting results with regard to the use of catheter-based techniques for continuous paravertebral block. Local anaesthetic spread within the paravertebral space is limited and the clinical effect is often variable. Discrepancies between needle tip position and final catheter position can also be problematic. The aim of this proof-of-concept study was to assess the reliability of placing a newly developed coiled catheter in human cadavers. Sixty Tuohy needles and coiled catheters were placed under ultrasound guidance, three on each side of the thoracic vertebral column in 10 human cadavers. Computed tomography was used to assess needle tip and catheter tip locations. No catheter was misplaced into the epidural, pleural or prevertebral spaces. The mean (SD) distance between catheter tips and needle tips was 8.2 (4.9) mm. The median (IQR [range]) caudo-cephalad spread of contrast dye injectate through a subset of 20 catheters was 4 (4-5[3-8]) thoracic segments. All catheters were removed without incident. Precise paravertebral catheter placement can be achieved using ultrasound-guided placement of a coiled catheter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We demonstrate a reliable microfabrication process for a combined atomic force microscopy (AFM) and scanning electrochemical microscopy (SECM) measurement tool. Integrated cone-shaped sensors with boron doped diamond (BDD) or gold (Au) electrodes were fabricated from commercially available AFM probes. The sensor formation process is based on mature semiconductor processing techniques, including focused ion beam (FIB) machining, and highly selective reactive ion etching (RIE). The fabrication approach preserves the geometry of the original AFM tips resulting in well reproducible nanoscaled sensors. The feasibility and functionality of the fully featured tips are demonstrated by cyclic voltammetry, showing good agreement between the measured and calculated currents of the cone-shaped AFM-SECM electrodes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To compare the performance of LFpen (DIAGNOdent pen) with two different wedge-shaped tips to conventional bitewing radiography (BW) for detecting proximal secondary caries at the cervical margin of amalgam restorations in vitro.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rabbits are born blind and deaf and receive unusually limited maternal care. Consequently, their suckling young heavily rely on the olfactory cue for nipple attachment. However, the postnatal morphofunctional adaptations of olfactory mucosa (OM) are not fully elucidated. To clarify on the extent and the pattern of refinement of the OM following birth in the rabbit, morphologic and morphometric analysis of the mucosa were done at neonatal (0-1 days), suckling (2 weeks), weanling (4 weeks), and adult (6-8 months) stages of postnatal development. In all the age groups, the basic components of the OM were present. However, proliferative activity of cells of the mucosal epithelium decreased with increasing age as revealed by Ki-67 immunostaining. Diameters of axon bundles, packing densities of olfactory cells, and cilia numbers per olfactory cell knob increased progressively with age being 5.5, 2.1, and 2.6 times, respectively, in the adult as compared with the neonate. Volume fraction values for the bundles increased by 5.3% from birth to suckling age and by 7.4% from weaning to adulthood and the bundle cores were infiltrated with blood capillaries in all ages except in the adult where such vessels were lacking. The pattern of cilia projection from olfactory cell knobs also showed age-related variations, that is, arose as a tuft from the tips of the knobs in neonates and sucklings and in a radial pattern from the knob bases in weanlings and adults. These morphological changes may be attributed to the high olfactory functional demand associated with postnatal development in the rabbit.