12 resultados para THERMAL RATE COEFFICIENT

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The vector channel spectral function and the dilepton production rate from a QCD plasma at a temperature above a few hundred MeV are evaluated up to next-to-leading order (NLO) including their dependence on a non-zero momentum with respect to the heat bath. The invariant mass of the virtual photon is taken to be in the range K2 ~ (πT)2 ~ (1GeV)2, generalizing previous NLO results valid for K2 ≫ (πT)2. In the opposite regime 0 < K2 ≪ (πT)2 the loop expansion breaks down, but agrees nevertheless in order of magnitude with a previous result obtained through resummations. Ways to test the vector spectral function through comparisons with imaginary-time correlators measured on the lattice are discussed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The production rate of right-handed neutrinos from a Standard Model plasma at a temperature above a hundred GeV is evaluated up to NLO in Standard Model couplings. The results apply in the so-called relativistic regime, referring parametrically to a mass M ~ πT, generalizing thereby previous NLO results which only apply in the non-relativistic regime M ≫ πT. The non-relativistic expansion is observed to converge for M ≳ 15T, but the smallness of any loop corrections allows it to be used in practice already for M ≳ 4T. In the latter regime any non-covariant dependence of the differential rate on the spatial momentum is shown to be mild. The loop expansion breaks down in the ultrarelativistic regime M ≪ πT, but after a simple mass resummation it nevertheless extrapolates reasonably well towards a result obtained previously through complete LPM resummation, apparently confirming a strong enhancement of the rate at high temperatures (which facilitates chemical equilibration). When combined with other ingredients the results may help to improve upon the accuracy of leptogenesis computations operating above the electroweak scale.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The thermal release rate of nuclear reaction products was investigated in offline annealing experiments. This work was motivated by the search for a high melting catcher material for recoiling products from heavy ion induced nuclear fusion reactions. Polycrystalline refractory metal foils of Ni, Y, Zr, Nb, Mo, Hf, W, and Re were investigated as catcher metals. Diffusion data for various tracer/host combinations were deduced from the measured release rates. This work focuses on the diffusion and the release rate of volatile p-elements from row 5 and 6 of the periodic table as lighter homologues of the superheavy elements with Z ≥ 113 to be studied in future experiments. A massive radiation damage enhancement of the diffusion velocity was observed. Diffusion trends have been established along the groups and rows of the periodic table based on the dependence of diffusion velocity on atomic sizes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Agricultural workers are exposed to various risks, including chemical agents, noise, and many other factors. One of the most characteristic and least known risk factors is constituted by the microclimatic conditions in the different phases of work (in field, in greenhouse, etc). A typical condition is thermal stress due to high temperatures during harvesting operations in open fields or in greenhouses. In Italy, harvesting is carried out for many hours during the day, mainly in the summer, with temperatures often higher than 30 degrees C. According to ISO 7243, these conditions can be considered dangerous for workers' health. The aim of this study is to assess the risks of exposure to microclimatic conditions (heat) for fruit and vegetable harvesters in central Italy by applying methods established by international standards. In order to estimate the risk for workers, the air temperature, radiative temperature, and air speed were measured using instruments in conformity with ISO 7726. Thermodynamic parameters and two more subjective parameters, clothing and the metabolic heat production rate related to the worker's physical activity, were used to calculate the predicted heat strain (PHS) for the exposed workers in conformity with ISO 7933. Environmental and subjective parameters were also measured for greenhouse workers, according to ISO 7243, in order to calculate the wet-bulb globe temperature (WBGT). The results show a slight risk for workers during manual harvesting in the field. On the other hand, the data collected in the greenhouses show that the risk for workers must not be underestimated. The results of the study show that, for manual harvesting work in climates similar to central Italy, it is essential to provide plenty of drinking water and acclimatization for the workers in order to reduce health risks. Moreover, the study emphasizes that the possible health risks for greenhouse workers increase from the month of April through July.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Laser tissue soldering (LTS) is a promising technique for tissue fusion based on a heat-denaturation process of proteins. Thermal damage of the fused tissue during the laser procedure has always been an important and challenging problem. Particularly in LTS of arterial blood vessels strong heating of the endothelium should be avoided to minimize the risk of thrombosis. A precise knowledge of the temperature distribution within the vessel wall during laser irradiation is inevitable. The authors developed a finite element model (FEM) to simulate the temperature distribution within blood vessels during LTS. Temperature measurements were used to verify and calibrate the model. Different parameters such as laser power, solder absorption coefficient, thickness of the solder layer, cooling of the vessel and continuous vs. pulsed energy deposition were tested to elucidate their impact on the temperature distribution within the soldering joint in order to reduce the amount of further animal experiments. A pulsed irradiation with high laser power and high absorbing solder yields the best results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The resting and maximum in situ cardiac performance of Newfoundland Atlantic cod (Gadus morhua) acclimated to 10, 4 and 0°C were measured at their respective acclimation temperatures, and when acutely exposed to temperature changes: i.e. hearts from 10°C fish cooled to 4°C, and hearts from 4°C fish measured at 10 and 0°C. Intrinsic heart rate (f(H)) decreased from 41 beats min(-1) at 10°C to 33 beats min(-1) at 4°C and 25 beats min(-1) at 0°C. However, this degree of thermal dependency was not reflected in maximal cardiac output (Q(max) values were ~44, ~37 and ~34 ml min(-1) kg(-1) at 10, 4 and 0°C, respectively). Further, cardiac scope showed a slight positive compensation between 4 and 0°C (Q(10)=1.7), and full, if not a slight over compensation between 10 and 4°C (Q(10)=0.9). The maximal performance of hearts exposed to an acute decrease in temperature (i.e. from 10 to 4°C and 4 to 0°C) was comparable to that measured for hearts from 4°C- and 0°C-acclimated fish, respectively. In contrast, 4°C-acclimated hearts significantly out-performed 10°C-acclimated hearts when tested at a common temperature of 10°C (in terms of both Q(max) and power output). Only minimal differences in cardiac function were seen between hearts stimulated with basal (5 nmol l(-1)) versus maximal (200 nmol l(-1)) levels of adrenaline, the effects of which were not temperature dependent. These results: (1) show that maximum performance of the isolated cod heart is not compromised by exposure to cold temperatures; and (2) support data from other studies, which show that, in contrast to salmonids, cod cardiac performance/myocardial contractility is not dependent upon humoral adrenergic stimulation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Heart rate variability (HRV) and cardiorespiratory coordination, i.e. the temporal interplay between oscillations of heartbeat and respiration, reflect information related to the cardiovascular and autonomic nervous system. The purpose of this study was to investigate the relationship between spectral measures of HRV and measures of cardiorespiratory coordination. In 127 subjects from a normal population a 24 h Holter ECG was recorded. Average heart rate (HR) and the following HRV parameters were calculated: very low (VLF), low (LF) and high frequency (HF) oscillations and LF/HF. Cardiorespiratory coordination was quantified using average respiratory rate (RespR), the ratio of heart rate and respiratory rate (HRR), the phase coordination ratio (PCR) and the extent of cardiorespiratory coordination (PP). Pearson's correlation coefficient r was used to quantify the relationship between each pair of the variables across all subjects. HR and HRR correlated strongest during daytime (r = 0.89). LF/HF and PP showed a negative correlation to a reasonable degree (r = -0.69). During nighttime sleep these correlations decreased whereas the correlation between HRR and RespR (r = -0.47) as well as between HRR and PCR (r = 0.73) increased substantially. In conclusion, HRR and PCR deliver considerably different information compared to HRV measures whereas PP is partially linked reciprocally to LF/HF.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When considering NLO corrections to thermal particle production in the “relativistic” regime, in which the invariant mass squared of the produced particle is K2 ~ (πT)2, then the production rate can be expressed as a sum of a few universal “master” spectral functions. Taking the most complicated 2-loop master as an example, a general strategy for obtaining a convergent 2-dimensional integral representation is suggested. The analysis applies both to bosonic and fermionic statistics, and shows that for this master the non-relativistic approximation is only accurate for K2 ~(8πT)2, whereas the zero-momentum approximation works surprisingly well. Once the simpler masters have been similarly resolved, NLO results for quantities such as the right-handed neutrino production rate from a Standard Model plasma or the dilepton production rate from a QCD plasma can be assembled for K2 ~ (πT)2.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The analytic continuation needed for the extraction of transport coefficients necessitates in principle a continuous function of the Euclidean time variable. We report on progress towards achieving the continuum limit for 2-point correlator measurements in thermal SU(3) gauge theory, with specific attention paid to scale setting. In particular, we improve upon the determination of the critical lattice coupling and the critical temperature of pure SU(3) gauge theory, estimating r0Tc ≃ 0.7470(7) after a continuum extrapolation. As an application the determination of the heavy quark momentum diffusion coefficient from a correlator of colour-electric fields attached to a Polyakov loop is discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Several parameters of heart rate variability (HRV) have been shown to predict the risk of sudden cardiac death (SCD) in cardiac patients. There is consensus that risk prediction is increased when measuring HRV during specific provocations such as orthostatic challenge. For the first time, we provide data on reproducibility of such a test in patients with a history of acute coronary syndrome. METHODS: Sixty male patients (65+/-8years) with a history of acute coronary syndrome on stable medication were included. HRV was measured in supine (5min) and standing (5min) position on 2 occasions separated by two weeks. For risk assessment relevant time-domain [standard deviation of all R-R intervals (SDNN) and root mean squared standard differences between adjacent R-R intervals (RMSSD)], frequency domain [low-frequency power (LF), high-frequency power (HF) and LF/HF power ratio] and short-term fractal scaling component (DF1) were computed. Absolute reproducibility was assessed with the standard errors of the mean (SEM) and 95% limits of random variation, and relative reproducibility by the intraclass correlation coefficient (ICC). RESULTS: We found comparable SEMs and ICCs in supine position and after an orthostatic challenge test. All ICCs were good to excellent (ICCs between 0.636 and 0.869). CONCLUSIONS: Reproducibility of HRV parameters during orthostatic challenge is good and comparable with supine position.