43 resultados para THE PREPARATION OF THE NOVEL
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
BACKGROUND: Chlorhexidine (CHX) rinsing after periodontal surgery is common. We assessed the clinical and microbiological effects of two CHX concentrations following periodontal surgery. MATERIALS AND METHODS: In a randomized, controlled clinical trial, 45 subjects were assigned to 4 weeks rinsing with a 0.05 CHX/herbal extract combination (test) or a 0.1% CHX solution. Clinical and staining effects were studied. Subgingival bacteria were assessed using the DNA-DNA checkerboard. Statistics included parametric and non-parametric tests (p<0001 to declare significance at 80% power). RESULTS: At weeks 4 and 12, more staining was found in the control group (p<0.05 and p<0.001, respectively). A higher risk for staining was found in the control group (crude OR: 2.3:1, 95% CI: 1.3 to 4.4, p<0.01). The absolute staining reduction in the test group was 21.1% (9 5% CI: 9.4-32.8%). Probing pocket depth (PPD) decreases were significant (p<0.001) in both groups and similar (p=0.92). No rinse group differences in changes of bacterial counts for any species were found between baseline and week 12. CONCLUSIONS: The test CHX rinse resulted in less tooth staining. At the study endpoint, similar and high counts of periodontal pathogens were found.
Resumo:
We describe a new, useful embolization technique applied to occlude narrow vessel branches (≤1.5 mm (0.06″) in diameter) by deployment of one hydrocoil, through a microcatheter, in a way similar to the way in which one might navigate through the vascular lumen with a guidewire.
Resumo:
This paper is meant to provide guidance to anyone wishing to write a neurological guideline for diagnosis or treatment, and is directed at the Scientist Panels and task forces of the European Federation of Neurological Societies (EFNS). It substitutes the previous guidance paper from 2004. It contains several new aspects: the guidance is now based on a change of the grading system for evidence and for the resulting recommendations, and has adopted The Grading of Recommendations, Assessment, Development and Evaluation system (GRADE). The process of grading the quality of evidence and strength of recommendations can now be improved and made more transparent. The task forces embarking on the development of a guideline must now make clearer and more transparent choices about outcomes considered most relevant when searching the literature and evaluating their findings. Thus, the outcomes chosen will be more critical, more patient-oriented and easier to translate into simple recommendations. This paper also provides updated practical recommendations for planning a guideline task force within the framework of the EFNS. Finally, this paper hopes to find the approval also by the relevant bodies of our future organization, the European Academy of Neurology.
Resumo:
AIMS: Although an added diagnostic and prognostic value of the global coronary artery calcification (CAC) score as an adjunct to single-photon emission computed tomography (SPECT)-myocardial perfusion image (MPI) has been repeatedly documented, none of the previous studies took advantage of the anatomic information provided by the unenhanced cardiac CT. Therefore, no co-registration has so far been used to match a myocardial perfusion defect with calcifications in the subtending coronary artery. To evaluate the prognostic value of integrating SPECT-MPI with CAC images were obtained from non-enhanced cardiac computed tomography (CT) for attenuation correction to predict major adverse cardiac events (MACE). METHODS AND RESULTS: Follow-up was obtained in 462 patients undergoing a 1-day stress/rest (99m)Tc-teterofosmin SPECT and non-enhanced cardiac CT for attenuation correction. Survival free of MACE was determined using the Kaplan-Meier method. After integrating MPI and CT findings, patients were divided into three groups (i) MPI defect matched by calcification (CAC ≥ 1) in the subtending coronary artery (ii) unmatched MPI and CT finding (iii) normal finding by MPI and CT. At a mean follow-up of 34.5 ± 13 months, a MACE was observed in 80 patients (33 death, 6 non-fatal myocardial infarction, 9 hospitalizations due to unstable angina, and 32 revascularizations). Survival analysis revealed the most unfavourable outcome (P < 0.001 log-rank test) for patients with a matched finding. CONCLUSION: In the present study, a novel approach using a combined integration of cardiac SPECT-CAC imaging allows for refined risk stratification, as a matched defect emerged as an independent predictor of MACE.
Resumo:
OBJECTIVE: A severely virilized 46, XX newborn girl was referred to our center for evaluation and treatment of congenital adrenal hyperplasia (CAH) because of highly elevated 17alpha-hydroxyprogesterone levels at newborn screening; biochemical tests confirmed the diagnosis of salt-wasting CAH. Genetic analysis revealed that the girl was compound heterozygote for a previously reported Q318X mutation in exon 8 and a novel insertion of an adenine between nucleotides 962 and 963 in exon 4 of the CYP21A2 gene. This 962_963insA mutation created a frameshift leading to a stop codon at amino acid 161 of the P450c21 protein. AIM AND METHODS: To better understand structure-function relationships of mutant P450c21 proteins, we performed multiple sequence alignments of P450c21 with three mammalian P450s (P450 2C8, 2C9 and 2B4) with known structures as well as with human P450c17. Comparative molecular modeling of human P450c21 was then performed by MODELLER using the X-ray crystal structure of rabbit P450 2B4 as a template. RESULTS: The new three dimensional model of human P450c21 and the sequence alignment were found to be helpful in predicting the role of various amino acids in P450c21, especially those involved in heme binding and interaction with P450 oxidoreductase, the obligate electron donor. CONCLUSION: Our model will help in analyzing the genotype-phenotype relationship of P450c21 mutations which have not been tested for their functional activity in an in vitro assay.
Resumo:
In 1960, the first case report on factor XIII deficiency was published describing a seven-year-old Swiss boy with a so far unknown bleeding disorder. Today, more than 60 mutations in the factor XIIIA- and B-subunit genes are known leading to congenital factor XIII deficiency. In the present study, we describe six novel mutations in the factor XIII A-subunit gene. Additionally, we present the molecular characterisation of the first described patient with congenital factor XIII deficiency. The six novel mutations include a small deletion, Glu202 delG, leading to a premature stop codon and truncation of the protein, and a splice site mutation at the exon 10/intron 10 boundary, +1G/A, giving rise to an incorrect spliced mRNA lacking exons 10 and 11. The remaining four mutations are characterised by the single amino acid changes Met159Arg, Gly215Arg, Trp375Cys, and His716Arg, and were expressed in COS-1 cells. Antigen levels and activity of the mutants were significantly reduced compared to the wild-type. The patient described in 1960 also shows a single amino acid change, Arg77Cys. Structural analysis of all mutant enzymes suggests several mechanisms leading to destabilisation of the protein.
Resumo:
OBJECTIVE: A novel biphasic calcium phosphate (CaP) granulate consisting of hydroxyapatite (HA) and beta-tricalciumphosphate (TCP) was compared with pure HA and pure TCP and with autograft as positive control. MATERIALS AND METHODS: Four standardized bone defects were prepared in both mandibular angles of 16 minipigs and grafted with autogenous bone chips, HA, HA/TCP (60% : 40%), or TCP. Histologic and histomorphometric analysis of bone formation and graft degradation followed healing periods of 2, 4, 8, and 24 weeks. RESULTS: 2 weeks: more bone formation in defects filled with autograft than with the three CaP materials (P<0.05). 4 weeks: bone formation differed significantly (P<0.05) between all four materials (autograft>TCP>HA/TCP>HA). 8 weeks: more bone formation in defects with autograft and TCP than with HA/TCP (P<0.05), and HA/TCP had more bone formation than HA (P<0.05). 24 weeks: no difference in bone formation between the groups. Autograft and TCP resorbed quickly and almost completely over 8 weeks, whereas HA/TCP and HA showed limited degradation over 24 weeks. CONCLUSION: All defects healed with mature lamellar bone and intimate contact between bone and the remaining graft material. The rate of bone formation corresponded to the content of TCP in the CaP materials.
Resumo:
OBJECTIVES: To evaluate whether or not preparation of the implant site with osteotomes instead of drilling may improve peri-implant bone density and/or osseointegration, and whether or not this further improves the predictability of immediate loading of SLA implants. MATERIAL AND METHODS: The second, third, and fourth premolars were extracted in both sides of the mandible in six dogs, and after at least 3 months four SLA implants were inserted into each side of the jaw. In three animals, the implant sites were prepared by means of osteotomes, while standard stepwise drilling was used in the remaining animals. In each side of the jaw, two non-adjacent implants were restored with single crowns 4 days after installation, while the remaining two implants were left without crowns to serve as non-loaded controls. After 2, 4, or 12 weeks of loading, specimens including the implants and surrounding tissues were obtained and processed for histologic analysis of undecalcified sections. RESULTS: All implants placed with osteotomes were lost (five before delivery of the crowns and the rest during the first week after loading). None of the conventionally inserted implants, however, was lost, and histomorphometrical analysis revealed similar soft- and hard peri-implant tissue characteristics at immediately loaded and non-loaded implants at all observation times. Average bone-to-implant contact was 59-72% at immediately loaded implants vs. 60-63% at non-loaded ones. CONCLUSION: Preparation of the implant site by means of osteotomes had a deleterious effect on osseointegration, while immediate loading of single, free-standing, SLA implants following a conventional surgical protocol did not jeopardize their osseointegration.
Resumo:
In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensure that the planned dosimetric coverage of the tumor volume is actually realized in the patient. Since the direction of setup fields often deviates from the direction of the treatment beams, extra dose is delivered to the patient during the acquisition of these portal images which may reach clinical relevance. The aim of this work was to develop a new acquisition mode for the PortalVision aS500 electronic portal imaging device from Varian Medical Systems that allows one to take portal images with reduced dose while keeping good image quality. The new acquisition mode, called RadMode, selectively enables and disables beam pulses during image acquisition allowing one to stop wasting valuable dose during the initial acquisition of "reset frames." Images of excellent quality can be taken with 1 MU only. This low dose per image facilitates daily setup verification with considerably reduced extra dose.