18 resultados para TELLER ACUITY CARDS
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Differences in treatment responses to ranibizumab injections observed within trials involving monthly (MARINA and ANCHOR studies) and quarterly (PIER study) treatment suggest that an individualized treatment regimen may be effective in neovascular age-related macular degeneration. In the present study, a drug and disease model was used to evaluate the impact of an individualized, flexible treatment regimen on disease progression.
Resumo:
We evaluated the near visual acuity of 40 dentists and its improvement by using different magnification devices. The acuity was tested with miniaturized E-optotype tests on a negatoscope under the following conditions: 1. natural visual acuity, 300 mm; 2. single lens loupe, 2×, 250 mm; 3. Galilean loupe, 2.5×, 380 mm; and 4. Keplerian loupe, 4.3×, 400 mm. In part 1, the influence of the magnification devices was investigated for all dentists. The Keplerian loupe obtained the highest visual acuity (4.64), followed by the Galilean loupe (2.43), the single lens loupe (1.42), and natural visual acuity (1.19). For part 2, the dentists were classified according to their age (?40 years). The younger dentists' group achieved a significantly higher visual acuity with all magnification devices (p<0.001). For part 3, the dentists were grouped according to their natural visual acuity. The group with the higher natural visual acuity achieved significantly higher visual acuity with all magnification devices than did the group of dentists with the lower natural visual acuity (p<0.01). It can be concluded that near visual acuity varies highly between individuals and decreases during the lifetime. Independent of age or natural vision, visual acuity can be significantly improved by using magnification devices.
Resumo:
The aim of this study was to evaluate the visual acuity of adult zebrafish by assessing the optokinetic reflex. Using a modified commercially available optomotor device (OptoMotry®), virtual three-dimensional gratings of variable spatial frequency or contrast were presented to adult zebrafish. In a first experiment, visual acuity was evaluated by changing the spatial frequency at different angular velocities. Thereafter, contrast sensitivity was evaluated by changing the contrast level at different spatial frequencies.
Resumo:
An investigation into the physical consequences of including a Jahn-Teller distorted Cu(II) ion within an antiferromagnetically coupled ring, [R(2)NH(2)][Cr(7)CuF(8)((O(2)C(t)Bu)(16))] is reported. Inelastic neutron scattering (INS) and electron paramagnetic resonance (EPR) spectroscopic data are simulated using a microscopic spin Hamiltonian, and show that the two Cr-Cu exchange interactions must be inequivalent. One Cr-Cu exchange is found to be antiferromagnetic and the other ferromagnetic. The geometry of the Jahn-Teller elongation is deduced from these results, and shows that a Jahn-Teller elongation axis must lie in the plane of the Cr(7)Cu wheel; the elongation is not observed by X-ray crystallography, due to positional disorder of the Cu site within the wheel. An electronic structure calculation confirms the structural distortion of the Cu site.
Resumo:
BACKGROUND: Visual acuity serves as only a rough gauge of macular function. The aim therefore was to ascertain whether central an assessment of the central visual field afforded a closer insight into visual function after removal of epiretinal membranes and Infracyanine-Green- or Trypan-Blue-assisted peeling of the inner limiting membrane. Patients and methods: Fourty-three patients undergoing pars-plana vitrectomy for the removal of epimacular membranes and dye-assisted peeling of the inner limiting membrane using either Infracyanine Green (n = 29; group 1) or Trypan Blue (n = 14; group 2) were monitored prospectively for 12 months. Preoperatively, and 1, 6 and 12 months postoperatively, distance and reading visual acuities were evaluated; the central visual field was assessed by automated static perimetry. RESULTS: Twelve months after surgery, distance and reading visual acuities had improved in both groups, but to a significant degree only in Trypan-Blue-treated eyes. The difference between the two groups was not significant. Likewise at this juncture, the mean size of the visual-field defect remained unchanged in Trypan-Blue-treated eyes (preoperative: 4.3 (SD 2.1) dB; 12 months: 4.0 (2.1) dB (p = 0.15)), but had increased in Infracyanine-Green-treated ones (from 5.3 (3.7) dB to 8.0 (5.2) dB (p = 0.027)). CONCLUSION: Unlike visual acuity, the central visual field had deteriorated in Infracyanine-Green-treated eyes but not in Trypan-Blue-treated eyes 12 months after surgery. Hence, as a predictor of functional outcome, testing of the central visual field may be a more sensitive gauge than visual acuity. Furthermore, Infracyanine Green may have a chronic and potentially clinically relevant effect on the macula which is not reflected in the visual acuity.
Resumo:
BACKGROUND: To determine the value of the distance doubling visual acuity test in the diagnosis of nonorganic visual loss in a comparative observational case series. METHODS: Twenty-one consecutive patients with nonorganic visual acuity loss and 21 subjects with organic visual loss as controls were included. Best corrected visual acuity was tested at the normal distance of 5 meters using Landolt Cs. The patient was then repositioned and best corrected visual acuity was tested with the previous optotypes at double the distance via a mirror. RESULTS: Nonorganic visual acuity loss was identified in 21 of 21 patients. Sensitivity and specificity of distance-doubling visual acuity test in functional visual loss were found to be 100% (CI; 83%-100%) and 100% (CI; 82%-100%), respectively. CONCLUSION: Distance doubling visual acuity test is widely used to detect nonorganic visual loss. Our results show that this test has a high specificity and sensitivity to detect nonorganic visual impairment.
Resumo:
OBJECTIVES This study examined the near visual acuity of dentists in relation to age and magnification under simulated clinical conditions. MATERIALS AND METHODS Miniaturized visual tests were performed in posterior teeth of a dental phantom head in a simulated clinical setting (dental chair, operating lamp, dental mirror). The visual acuity of 40 dentists was measured under the following conditions: (1) natural visual acuity, distance of 300 mm; (2) natural visual acuity, free choice of distance; (3) Galilean loupes, magnification of ×2.5; (4) Keplerian loupes, ×4.3; (5) operating microscope, ×4, integrated light; (6) operating microscope, ×6.4, integrated light. RESULTS The visual acuity varied widely between individuals and was significantly lower in the group ≥40 years of age (p < 0.001). Significant differences were found between all tested conditions (p < 0.01). Furthermore, a correlation between visual acuity and age was found for all conditions. The performance with the microscope was better than with loupes even with comparable magnification factors. Some dentists had a better visual acuity without optical aids than others with Galilean loupes. CONCLUSIONS Near visual acuity under simulated clinical conditions varies widely between individuals and decreases throughout life. Visual deficiencies can be compensated for with optical aids. CLINICAL RELEVANCE Newly developed miniaturized vision tests have allowed, in a clinically relevant way, to evaluate the influence of magnification and age on the near visual acuity of dentists.
Resumo:
Epidemiological, clinical, and experimental evidence has accumulated during the last decades suggesting that high-density lipoproteins (HDLs) may protect from atherosclerosis and its clinical consequences. However, more than 55 years after the first description of the link between HDL and heart attacks, many facets of the biochemistry, function, and clinical significance of HDL remain enigmatic. This applies particularly to the completely unexpected results that became available from some recent clinical trials of nicotinic acid and of inhibitors of cholesteryl ester transfer protein (CETP). The concept that raising HDL cholesterol by pharmacological means would decrease the risk of vascular disease has therefore been challenged.
Resumo:
OBJECTIVES This study examined the impact of age and magnification on the near visual acuity of dentists in their private practice under simulated clinical conditions. MATERIALS AND METHODS Miniaturized visual tests were fixed in posterior teeth of a dental phantom head and brought to 31 dentists in their respective private practice. The visual acuity of these dentists (n = 19, ≥40 years; n = 12, <40 years) was measured in a clinical setting under the following conditions: (a) natural visual acuity, distance of 300 mm; (b) natural visual acuity, free choice of the distance; and (c) loupe and additional light source, if available. RESULTS The visual acuity under the different clinical conditions varied widely between individuals. The older group of dentists had a lower median visual acuity value under all clinical conditions. This difference was highly significant for natural visual acuity at a free choice of distance (p < 0.0001). For younger dentists (<40 years), visual acuity could be significantly improved by reducing the eye-object distance (p = 0.001) or by using loupes (p = 0.008). For older dentists (≥40 years), visual acuity could be significantly improved by using loupes (p = 0.0005). CONCLUSIONS Visual performance decreased with increasing age under the specific clinical conditions of each dentist's private practice. Magnification aids can compensate for visual deficiencies. CLINICAL RELEVANCE The question of whether findings obtained under standardized conditions are valuable for the habitual setting of each dentist's private practice seems clinically relevant.
Resumo:
BACKGROUND Patients with downbeat nystagmus syndrome suffer from oscillopsia, which leads to an unstable visual perception and therefore impaired visual acuity. The aim of this study was to use real-time computer-based visual feedback to compensate for the destabilizing slow phase eye movements. METHODS The patients were sitting in front of a computer screen with the head fixed on a chin rest. The eye movements were recorded by an eye tracking system (EyeSeeCam®). We tested the visual acuity with a fixed Landolt C (static) and during real-time feedback driven condition (dynamic) in gaze straight ahead and (20°) sideward gaze. In the dynamic condition, the Landolt C moved according to the slow phase eye velocity of the downbeat nystagmus. The Shapiro-Wilk test was used to test for normal distribution and one-way ANOVA for comparison. RESULTS Ten patients with downbeat nystagmus were included in the study. Median age was 76 years and the median duration of symptoms was 6.3 years (SD +/- 3.1y). The mean slow phase velocity was moderate during gaze straight ahead (1.44°/s, SD +/- 1.18°/s) and increased significantly in sideward gaze (mean left 3.36°/s; right 3.58°/s). In gaze straight ahead, we found no difference between the static and feedback driven condition. In sideward gaze, visual acuity improved in five out of ten subjects during the feedback-driven condition (p = 0.043). CONCLUSIONS This study provides proof of concept that non-invasive real-time computer-based visual feedback compensates for the SPV in DBN. Therefore, real-time visual feedback may be a promising aid for patients suffering from oscillopsia and impaired text reading on screen. Recent technological advances in the area of virtual reality displays might soon render this approach feasible in fully mobile settings.