5 resultados para System Use
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
BACKGROUND AND STUDY AIMS Colorectal cancer (CRC) incidence ranks third among all cancers in Switzerland. Screening the general population could decrease CRC incidence and mortality. The aim of this study was to analyze the use of the fecal occult blood test (FOBT) and lower gastrointestinal endoscopy in a representative sample of the Swiss population aged ≥ 50 years. METHODS Data were analyzed from the 2007 Swiss Health Interview Survey and the prevalence estimates and 95 % confidence intervals were calculated based on all instances of lower gastrointestinal endoscopy and FOBT use, as well as on their use for CRC screening. Uni- and multivariate logistic regression analyses were performed to describe the association between screening use and sociodemographic characteristics, indicators of healthcare system use, and lifestyle factors. RESULTS In 2007, approximately 36 % of the surveyed people who were aged ≥ 50 years had previously undergone FOBT and approximately 30 % had previously undergone lower gastrointestinal endoscopy. CRC screening use was 7.7 % for FOBT (within the past year) and 6.4 % for lower gastrointestinal endoscopy (within the past 5 years). CRC screening by either method was 13 %. The major determinants of participation in CRC screening were found to be sex (male), physician visits during the past year (one or more), type of health insurance (private), and previous screening for other cancer types. CONCLUSIONS The results of the 2007 Swiss Health Interview Survey indicate rather low levels of FOBT and lower gastrointestinal endoscopy use. Furthermore, the results suggest disparities in the use of CRC screening.
Resumo:
This study evaluates the clinical applicability of administering sodium nitroprusside by a closed-loop titration system compared with a manually adjusted system. The mean arterial pressure (MAP) was registered every 10 and 30 sec during the first 150 min after open heart surgery in 20 patients (group 1: computer regulation) and in ten patients (group 2: manual regulation). The results (16,343 and 2,912 data points in groups 1 and 2, respectively), were then analyzed in four time frames and five pressure ranges to indicate clinical efficacy. Sixty percent of the measured MAP in both groups was within the desired +/- 10% during the first 10 min. Thereafter until the end of observation, the MAP was maintained within +/- 10% of the desired set-point 90% of the time in group 1 vs. 60% of the time in group 2. One percent and 11% of data points were +/- 20% from the set-point in groups 1 and 2, respectively (p less than .05, chi-square test). The computer-assisted therapy provided better control of MAP, was safe to use, and helped to reduce nursing demands.
Resumo:
BACKGROUND Mechanical autotransfusion systems for washed shed blood (WSB) were introduced to reduce the need for postoperative allogenic blood transfusions (ABTs). Although some authors have postulated decreased requirements for ABT by using autologous retransfusion devices, other trials, mostly evaluating retransfusion devices for unwashed shed blood (USB), verified a small or no benefit in reducing the need for postoperative ABT. Because of these contradictory findings it is still unclear whether autologous retransfusion systems for WSB can reduce transfusion requirements. QUESTIONS/PURPOSES We therefore asked whether one such autologous transfusion system for WSB can reduce the requirements for postoperative ABT. METHODS In a prospective, randomized, controlled study, we enrolled 151 patients undergoing TKA. In Group A (n=76 patients), the autotransfusion system was used for a total of 6 hours (intraoperatively and postoperatively) and the WSB was retransfused after processing. In Control Group B (n=75 patients), a regular drain without suction was used. We used signs of anemia and/or a hemoglobin value less than 8 g/dL as indications for transfusion. If necessary, we administered one or two units of allogenic blood. RESULTS Twenty-three patients (33%) in Group A, who received an average of 283 mL (range, 160-406 mL) of salvaged blood, needed a mean of 2.1 units of allogenic blood, compared with 23 patients (33%) in Control Group B who needed a mean of 2.1 units of allogenic blood. CONCLUSIONS We found the use of an autotransfusion system did not reduce the rate of postoperative ABTs. LEVEL OF EVIDENCE Level II, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.