36 resultados para Symbolic Analysis Laboratory
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
ROTEM(®) is considered a helpful point-of-care device to monitor blood coagulation. Centrally performed analysis is desirable but rapid transport of blood samples and real-time transmission of graphic results are an important prerequisite. The effect of sample transport through a pneumatic tube system on ROTEM(®) results is unknown. The aims of the present work were (i) to determine the influence of blood sample transport through a pneumatic tube system on ROTEM(®) parameters compared to manual transportation, and (ii) to verify whether graphic results can be transmitted on line via virtual network computing using local area network to the physician in charge of the patient.
Resumo:
This study evaluated the correlation between three strip-type, colorimetric tests and two laboratory methods with respect to the analysis of salivary buffering. The strip-type tests were saliva-check buffer, Dentobuff strip and CRT(®) Buffer test. The laboratory methods included Ericsson's laboratory method and a monotone acid/base titration to create a reference scale for the salivary titratable acidity. Additionally, defined buffer solutions were prepared and tested to simulate the carbonate, phosphate and protein buffer systems of saliva. The correlation between the methods was analysed by the Spearman's rank test. Disagreement was detected between buffering capacity values obtained with three strip-type tests that was more pronounced in case of saliva samples with medium and low buffering capacities. All strip-type tests were able to assign the hydrogencarbonate, di-hydrogenphosphate and 0.1% protein buffer solutions to the correct buffer categories. However, at 0.6% total protein concentrations, none of the test systems worked accurately. Improvements are necessary for strip-type tests because of certain disagreement with the Ericsson's laboratory method and dependence on the protein content of saliva.
Resumo:
The University of Bern has set up the new Laboratory for the Analysis of Radiocarbon with AMS (LARA) equipped with an accelerator mass spectrometer (AMS) MICADAS (MIni CArbon Dating System) to continue its long history of 14C analysis based on conventional counting. The new laboratory is designated to provide routine 14C dating for archaeology, climate research, and other disciplines at the University of Bern and to develop new analytical systems coupled to the gas ion source for 14C analysis of specific compounds or compound classes with specific physical properties. Measurements of reference standards and wood samples dated by dendrochronology demonstrate the quality of the 14C analyses performed at the new laboratory.
Resumo:
During the last 10 years several molecular markers have been established as useful tools among the armamentarium of a hematologist. As a consequence, the number of performed hematologic molecular analyses has immensely increased. Often, such tests replace or complement other laboratory methods. Molecular markers can be useful in many ways: they can serve for diagnostics, describe the prognostic profile, predict which types of drugs are indicated, and can be used for the therapeutic monitoring of the patient to indicate an adequate response or predict resistance or relapse of the disease. Many markers fulfill more than one of these aspects. Most important, however, is the right choice of analyses at the right time-points!
Resumo:
ROTEM® is considered a helpful point-of-care device to monitor blood coagulation in emergency situations. Centrally performed analysis is desirable but rapid transport of blood samples is an important prerequisite. The effect of acceleration forces on sample transport through a pneumatic tube system on ROTEM® should be tested at each institution to exclude a pre-analytical influence. The aims of the present work were: (i) to investigate the effect of pneumatic tube transport on ROTEM® parameters; (ii) to compare blood sample transport via pneumatic tube vs. manual transportation; and (iii) to determine the effect of acceleration forces on ROTEM® parameters.
Resumo:
Two hemotropic mycoplasmas have been recognized in cats, Mycoplasma haemofelis and "Candidatus Mycoplasma haemominutum." We recently described a third feline hemoplasma species, designated "Candidatus Mycoplasma turicensis," in a Swiss cat with hemolytic anemia. This isolate induced anemia after experimental transmission to two specific-pathogen-free cats and analysis of the 16S rRNA gene revealed its close relationship to rodent hemotropic mycoplasmas. The agent was recently shown to be prevalent in Swiss pet cats. We sought to investigate the presence and clinical importance of "Candidatus Mycoplasma turicensis" infection in pet cats outside of Switzerland and to perform the molecular characterization of isolates from different countries. A "Candidatus Mycoplasma turicensis"-specific real-time PCR assay was applied to blood samples from 426 United Kingdom (UK), 147 Australian, and 69 South African pet cats. The 16S rRNA genes of isolates from different countries were sequenced and signalment and laboratory data for the cats were evaluated for associations with "Candidatus Mycoplasma turicensis" infection. Infections were detected in samples from UK, Australian, and South African pet cats. Infection was associated with the male gender, and "Candidatus Mycoplasma haemominutum" and M. haemofelis coinfection. Coinfected cats exhibited significantly lower packed cell volume (PCV) values than uninfected cats. Phylogenetic analyses revealed that some Australian and South African "Candidatus Mycoplasma turicensis" isolates branched away from the remaining isolates. In summary, "Candidatus Mycoplasma turicensis" infection in pet cats exists over a wide geographical area and significantly decreased PCV values are observed in cats coinfected with other feline hemoplasmas.
Resumo:
PURPOSE: The low diagnostic yield of vitrectomy specimen analysis in chronic idiopathic uveitis (CIU) has been related to the complex nature of the underlying disease and to methodologic and tissue immanent factors in older studies. In an attempt to evaluate the impact of recently acquired analytic methods, the authors assessed the current diagnostic yield in CIU. METHODS: Retrospective analysis of consecutive vitrectomy specimens from patients with chronic endogenous uveitis (n = 56) in whom extensive systemic workup had not revealed a specific diagnosis (idiopathic) and medical treatment had not resulted in a satisfying clinical situation. Patients with acute postoperative endophthalmitis served a basis for methodologic comparison (Group 2; n = 21). RESULTS: In CIU, a specific diagnosis provided in 17.9% and a specific diagnosis excluded in 21.4%. In 60.7% the laboratory investigations were inconclusive. In postoperative endophthalmitis, microbiological culture established the infectious agent in 47.6%. In six of eight randomly selected cases, eubacterial PCR identified bacterial DNA confirming the culture results in three, remaining negative in two with a positive culture and being positive in three no growth specimens. A double negative result never occurred, suggesting a very high detection rate, when both tests were applied. CONCLUSIONS: The diagnostic yield of vitrectomy specimen analysis has not been improved by currently routinely applied methods in recent years in contrast to the significantly improved sensitivity of combined standardized culture and PCR analysis in endophthalmitis. Consequently, the low diagnostic yield in CIU has to be attributed to insufficient understanding of the underlying pathophysiologic mechanisms.
Resumo:
PURPOSE: A microangiographical technique is described, which allows visualization of small and capillary blood vessels and quantification of fasciocutaneous blood vessels by means of digital computer analysis in very small laboratory animals. MATERIALS AND METHODS: The left carotid artery of 20 nu/nu mice was cannulated (26 gauge) and a mixture of gelatin, bariumsulfate, and green ink was injected according to standardized protocol. Fasciocutaneous blood vessels were visualized by digital mammography and analyzed for vessel length and vessel surface area as standardized units [SU] by computer program. RESULTS: With the described microangiography method, fasciocutaneous blood vessels down to capillary size level can be clearly visualized. Regions of interest (ROIs) can be defined and the containing vascular network quantified. Comparable results may be obtained by calculating the microvascular area index (MAI) and the microvascular length index (MLI), related to the ROIs size. Identical ROIs showed a high reproducibility for measured [SU] < 0.01 +/- 0.0012%. CONCLUSION: Combining microsurgical techniques, pharmacological knowledge, and modern digital image technology, we were able to visualize small and capillary blood vessels even in small laboratory animals. By using our own computer analytical program, quantification of vessels was reliable, highly reproducible, and fast.
Resumo:
Alveolar echinococcosis (AE)--caused by the cestode Echinococcus multilocularis--is a severe zoonotic disease found in temperate and arctic regions of the northern hemisphere. Even though the transmission patterns observed in different geographical areas are heterogeneous, the nuclear and mitochondrial targets usually used for the genotyping of E. multilocularis have shown only a marked genetic homogeneity in this species. We used microsatellite sequences, because of their high typing resolution, to explore the genetic diversity of E. multilocularis. Four microsatellite targets (EmsJ, EmsK, and EmsB, which were designed in our laboratory, and NAK1, selected from the literature) were tested on a panel of 76 E. multilocularis samples (larval and adult stages) obtained from Alaska, Canada, Europe, and Asia. Genetic diversity for each target was assessed by size polymorphism analysis. With the EmsJ and EmsK targets, two alleles were found for each locus, yielding two and three genotypes, respectively, discriminating European isolates from the other groups. With NAK1, five alleles were found, yielding seven genotypes, including those specific to Tibetan and Alaskan isolates. The EmsB target, a tandem repeated multilocus microsatellite, found 17 alleles showing a complex pattern. Hierarchical clustering analyses were performed with the EmsB findings, and 29 genotypes were identified. Due to its higher genetic polymorphism, EmsB exhibited a higher discriminatory power than the other targets. The complex EmsB pattern was able to discriminate isolates on a regional and sectoral level, while avoiding overdistinction. EmsB will be used to assess the putative emergence of E. multilocularis in Europe.
Resumo:
SETTING: Kinshasa Province, Democratic Republic of Congo. OBJECTIVE: To identify and validate register-based indicators of acid-fast bacilli (AFB) microscopy quality. DESIGN: Selection of laboratories based on reliability and variation in routine smear rechecking results. Calculation of relative sensitivity (RS) compared to recheckers and its correlation coefficient (R) with candidate indicators based on a fully probabilistic analysis incorporating vague prior information using WinBUGS. RESULTS: The proportion of positive follow-up smears correlated well (median R 0.81, 95% credibility interval [CI] 0.58-0.93), and the proportion of first smear-positive cases fairly (median R 0.70, 95% CI 0.38-0.89) with RS. The proportions of both positive suspect and low positive case smears showed poor correlations (median R 0.27 and -0.22, respectively, with ranges including zero). CONCLUSIONS: The proportion of positives in follow-up smears is the most promising indicator of AFB smear sensitivity, while the proportion of positive suspects may be more indicative of accessibility and suspect selection. Both can be obtained from simple reports, and should be used for internal and external monitoring and as guidance for supervision. As proportion of low positive suspect smears and consistency within case series are more difficult to interpret, they should be used only on-site by laboratory professionals. All indicators require more research to define their optimal range in various settings.
Resumo:
Impulsivity is a multifaceted construct that defines a range of maladaptive behavioral styles. The present research aimed to identify different dimensions of impulsive behavior in adolescents from a battery of laboratory behavioral assessments. In one analysis, correlations were examined between two self report and seven laboratory behavioral measures of impulsivity. The correlation between the two self report measures was high compared to correlations between the self report and laboratory behavioral measures. In a second analysis, a principal components analysis was performed with just the laboratory behavioral measures. Three behavioral dimensions were identified -- "impulsive decision-making", "impulsive inattention", and "impulsive disinhibition". These dimensions were further evaluated using the same sample with a confirmatory factor analysis, which did support the hypothesis that these are significant and independent dimensions of impulsivity. This research indicates there are at least three separate subtypes of impulsive behavior when using laboratory behavioral assessments with adolescent participants.