3 resultados para Suspension system

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reactive oxygen species (ROS) production is important in the toxicity of pathogenic particles such as fibres. We examined the oxidative potential of straight (50 microm and 10 microm) and tangled carbon nanotubes in a cell free assay, in vitro and in vivo using different dispersants. The cell free oxidative potential of tangled nanotubes was higher than for the straight fibres. In cultured macrophages tangled tubes exhibited significantly more ROS at 30 min, while straight tubes increased ROS at 4 h. ROS was significantly higher in bronchoalveolar lavage cells of animals instilled with tangled and 10 mum straight fibres, whereas the number of neutrophils increased only in animals treated with the long tubes. Addition of dispersants in the suspension media lead to enhanced ROS detection by entangled tubes in the cell-free system. Tangled fibres generated more ROS in a cell-free system and in cultured cells, while straight fibres generated a slower but more prolonged effect in animals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ventricular assist devices (VADs) and total artificial hearts have been in development for the last 50 years. Since their inception, simulators of the circulation with different degrees of complexity have been produced to test these devices in vitro. Currently, a new path has been taken with the extensive efforts to develop paediatric VADs, which require totally different design constraints. This paper presents the manufacturing details of an economical simulator of the systemic paediatric circulation. This simulator allows the insertion of a paediatric VAD, includes a pumping ventricle, and is adjustable within the paediatric range. Rather than focusing on complexity and physiological simulation, this simulator is designed to be simple and practical for rapid device testing. The simulator was instrumented with medical sensors and data were acquired under different conditions with and without the new PediaFlowTM paediatric VAD. The VAD was run at different impeller speeds while simulator settings such as vascular resistance and stroke volume were varied. The hydraulic performance of the VAD under pulsatile conditions could be characterized and the magnetic suspension could be tested via manipulations such as cannula clamping. This compact mock loop has proven to be valuable throughout the PediaFlow development process and has the advantage that it is uncomplicated and can be manufactured cheaply. It can be produced by several research groups and the results of different VADs can then be compared easily.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION An accurate description of the biomechanical behavior of the spine is crucial for the planning of scoliotic surgical correction as well as for the understanding of degenerative spine disorders. The current clinical assessments of spinal mechanics such as side-bending or fulcrum-bending tests rely on the displacement of the spine observed during motion of the patient. Since these tests focused solely on the spinal kinematics without considering mechanical loads, no quantification of the mechanical flexibility of the spine can be provided. METHODS A spinal suspension test (SST) has been developed to simultaneously monitor the force applied on the spine and the induced vertebral displacements. The system relies on cervical elevation of the patient and orthogonal radiographic images are used to measure the position of the vertebras. The system has been used to quantify the spinal flexibility on five AIS patients. RESULTS Based on the SST, the overall spinal flexibility varied between 0.3 °/Nm for the patient with the stiffer curve and 2 °/Nm for the less rigid curve. A linear correlation was observed between the overall spinal flexibility and the change in Cobb angle. In addition, the segmental flexibility calculated for five segments around the apex was 0.13 ± 0.07 °/Nm, which is similar to intra-operative stiffness measurements previously published. CONCLUSIONS In summary, the SST seems suitable to provide pre-operative information on the complex functional behavior and stiffness of spinal segments under physiological loading conditions. Such tools will become increasingly important in the future due to the ever-increasing complexity of the surgical instrumentation and procedures.