226 resultados para Surgery, computed tomography excretory

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To analyze the dimensions and anatomic characteristics of the nasopalatine canal and the corresponding buccal bone plate of the alveolar process, using limited cone-beam computed tomography (CBCT) imaging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To determine the dimensions of the Schneiderian membrane using limited cone beam computed tomography (CBCT) in individuals referred for dental implant surgery, and to determine factors influencing the mucosal thickness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the detectability and dimensions of periapical lesions, the relationship of the mandibular canal to the roots of the respective teeth, and the dimension of the buccal bone by using limited cone-beam computed tomography (CBCT) in comparison to conventional periapical (PA) radiographs for evaluation of mandibular molars before apical surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present study was to compare conventional intraoral periapical radiographs (PA) with limited cone beam computed tomography (CBCT) for evaluation of mandibular molars prior to apical surgery. The apical extent and homogeneity of the root canal fillings (RCF) as well as the number of root canals were examined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the thickness and the anatomic characteristics of the Schneiderian membrane and cortical bone using limited cone beam computed tomography (CBCT) scannning in patients referred for planning of apical surgery of maxillary molars.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: Patient management following elective cranial surgery varies between different neurosurgical institutions. Early routine postoperative cranial computed tomography (CT) is often performed while keeping patients sedated and ventilated for several hours. We hypothesize that fast track management without routine CT scanning, i.e., early extubation within one hour allowing neurological monitoring, is safe and does not increase the rate of return to OR compared with published data. Methods: We prospectively screened 1118 patients with cranial procedures performed at our department over a period of two years. 420 patients with elective brain surgery older than 18 years with no history of prior cranial surgery were included. Routine neurosurgical practice as it is performed at our department was not altered for this observational study. Fast track management was aimed for all cases, extubated and awake patients were further monitored. CT scanning within 48 hours after surgery was not performed except for unexpected neurological deterioration. This study was registered at ClinicalTrials.gov (NCT01987648). Results: 420 elective craniotomies were performed for 310 supra- and 110 infratentorial lesions. 398 patients (94.8%) were able to be extubated within 1 hour, 21 (5%) within 6 hours, and 1 patient (0.2%) was extubated 9 hours after surgery. Emergency CT within 48 hours was performed for 36 patients (8.6%, 26 supra- and 10 infratentorial cases) due to unexpected neurological worsening. Of these 36 patients 5 had to return to the OR (hemorrhage in 3, swelling in 2 cases). Return to OR rate of all included cases was 1.2%. This rate compares favorably with 1-4% as quoted in the current literature. No patient returned to the OR without prior CT imaging. Of 398 patients extubated within one hour 2 (0.5%) returned to the OR. Patients who couldn’t be extubated within the first hour had a higher risk of returning to the OR (3 of 22, i.e., 14%). Overall 30-day mortality was 0.2% (1 patient). Conclusions: Early extubation and CT imaging performed only for patients with unexpected neurological worsening after elective craniotomy procedures is safe and does not increase patient mortality or the return to OR rate. With this fast track approach early postoperative cranial CT for detection of postoperative complications in the absence of an unexpected neurological finding is not justified. Acknowledgments The authors thank Nicole Söll, study nurse, Department of Neurosurgery, Bern University Hospital, Switzerland for crucial support in data collection and managing the database.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To assess retrospectively the frequency and location of mandibular lingual foramina and their bony canals with limited cone-beam computed tomography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluates the dimensions of nasopalatine duct cysts (NPDCs) and the involvement of neighboring anatomical structures using standardized limited cone beam computed tomography (CBCT) and a possible correlation to the patient's age, gender, preoperative symptoms, and postsurgical complications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Advances in diagnostic imaging and the introduction of damage control strategy in trauma have influenced our approach to treating liver trauma patients. The objective of the present study was to investigate the impact of change in liver trauma management on outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Integrity of the abdominal aortic aneurysm (AAA) neck is crucial for the long-term success of endovascular AAA repair (EVAR). However, suitable tools for reliable assessment of changes in small aortic volumes are lacking. The purpose of this study was to assess the intraobserver and interobserver variability of software-enhanced 64-row computed tomographic angiography (CTA) AAA neck volume measurements in patients after EVAR. METHODS: A total of 25 consecutive patients successfully treated by EVAR underwent 64-row follow-up CTA in 1.5-mm collimation. Manual CTA measurements were performed twice by three blinded and independent readers in random order with at least a 4-week interval between readings. Maximum and minimum transverse aortic neck diameters were measured twice on two different levels within the proximal neck. Volumetry of the proximal aortic neck was performed by using dedicated software. Variability was calculated as 1.96 SD of the mean arithmetic difference according to Bland and Altman. Two-sided and paired t tests were used to compare measurements. P values <.05 were considered to indicate statistical significance. RESULTS: Intraobserver agreement was excellent for dedicated aneurysmal neck volumetry, with mean differences of less than 1 mL (P > .05), whereas it was poor for transverse aortic neck diameter measurements (P < .05). However, interobserver variability was statistically significant for both neck volumetry (P < .005) and neck diameter measurements (P < .015). CONCLUSIONS: The reliability of dedicated AAA neck volumetry by using 64-row CTA is excellent for serial measurements by individual readers, but not between different readers. Therefore, studies should be performed with aortic neck volumetry by a single experienced reader.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to obtain comprehensive data on clinical presentation, microbiology, computed tomography, surgical findings and histology in acute, sub-acute and chronic mastoiditis. We performed a prospective, observational study in children under 16 years of age presenting to our institution during the 2-year period beginning in April 2000. The children were examined and their condition treated in accordance with a standardized protocol elaborated by the paediatric, otolaryngology (ORL) and radiology departments. Thirty-eight patients were hospitalized (22 with acute mastoiditis, seven with sub-acute mastoiditis, nine with chronic mastoiditis). There were 30 complications present in 21 patients (55%). Streptococcus pyogenes was the most common pathogen (7/24 cases), followed by Streptococcus pneumoniae (4/24 cases). Mastoid surgery was performed in 29 patients. Histology of mastoid tissue revealed predominantly acute inflammation in two cases, mixed acute/chronic inflammation in 19 cases and predominantly chronic inflammation in seven cases. Radiologic data were evaluated retrospectively. Spiral, volume-based high-resolution (HR) computed tomography (CT) of the temporal bone had a sensitivity of 100%, specificity of 38%, positive predictive value (PPV) of 50% and negative predictive value (NPV) of 100% in detecting coalescence of mastoid trabeculae. Cranial CT with contrast had a sensitivity of 80%, specificity of 94%, PPV of 80% and NPV of 94% in identifying intra-cranial extension. Conclusion: histological evidence suggests that sub-acute/chronic infection underlies not only sub-acute and chronic mastoiditis, but most cases of acute mastoiditis as well. HR-CT of the temporal bone is effective in ruling out coalescence. Cranial CT is valuable in identifying intra-cranial extension. Cranial and HR-CT are recommended in the examination of children with mastoiditis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Component malpositioning and postoperative leg length discrepancy are the most common technical problems associated with total hip arthroplasty (THA). Surgical navigation offers the potential to reduce the incidence of these problems. We reviewed 317 patients (344 hips) that underwent THA using computed tomography-based surgical navigation, including 112 THAs using a simplified method of measuring leg length. Guided by the navigation system, cups were placed in 40.8 degrees +/- 2 degrees of operative abduction (range, 35 degrees -50 degrees) and 30.8 degrees +/- 3.2 degrees (range, 19 degrees -43 degrees) of operative anteversion. We subsequently measured radiographic abduction on plain anteroposterior pelvic radiographs and calculated abduction and anteversion. Radiographically, 97.1 % of the cups were in the safe zone for abduction and 92.4% for anteversion. The mean incision length was less than 8 cm for 327 of the 344 hips. Leg length change measured intraoperatively was 6.6 +/- 4.1 mm (range, -2-22), similar to measurements from the pre- and postoperative magnification-corrected radiographs. Computer assistance during THA increased the consistency of component positioning and allowed reliable measurement of leg length change during surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: This retrospective study was conducted to determine whether a low-volume contrast medium protocol provides sufficient enhancement for 64-detector computed tomography angiography (CTA) in patients with aortoiliac aneurysms. METHODS: Evaluated were 45 consecutive patients (6 women; mean age, 72 +/- 6 years) who were referred for aortoiliac computed tomography angiography between October 2005 and January 2007. Group A (22 patients; creatinine clearance, 64.2 +/- 8.1 mL/min) received 50 mL of the contrast agent. Group B (23 patients; creatinine clearance, 89.4 +/- 7.3 mL/min) received 100 mL of the contrast agent. The injection rate was 3.5 mL/s, followed by 30 mL of saline at 3.5 mL/s. Studies were performed on the same 64-detector computed tomography scanner using a real-time bolus-tracking technique. Quantitative analysis was performed by determination of mean vascular attenuation at 10 regions of interest from the suprarenal aorta to the common femoral artery by one reader blinded to type and amount of contrast agent and compared using the Student t test. Image quality according to a 4-point scale was assessed in consensus by two readers blinded to type and amount of contrast medium and compared using the Mann-Whitney test. Multivariable adjustments were performed using ordinal regression analysis. RESULTS: Mean total attenuation did not differ significantly between both groups (196.5 +/- 33.0 Hounsfield unit [HU] in group A and 203.1 +/- 44.2 HU in group B; P = .57 by univariate and P > .05 by multivariable analysis). Accordingly, attenuation at each region of interest was not significantly different (P > .35). Image quality was excellent or good in all patients. No significant differences in visual assessment were found comparing both contrast medium protocols (P > .05 by univariate and by multivariable analysis). CONCLUSIONS: Aortoiliac aneurysm imaging can be performed with substantially reduced amounts of contrast medium using 64-detector computed tomography angiography technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Operative fixation of intraarticular distal radius fractures is increasingly common. A greater understanding of fracture patterns will aid surgical fixation strategy. Previous studies have suggested that ligamentous insertions may less commonly be involved, but these have included heterogeneous groups of fractures and have not addressed Lister's tubercle. Purpose We hypothesize that fracture lines of distal radial intraarticular 2-part fractures have reproducible patterns. They propagate through the cortical bone between ligament origins and do not involve Lister's tubercle. Methods Axial CT scans of two-part intraarticular distal radius fractures were assessed independently by two examiners. The fractures were mapped onto a grid and the cortical breaches expressed as a percentile of the total radial width or length. The cortical breaches were compared with the ligamentous insertions on the distal and Lister's tubercle. Associated injuries were also documented. Results The cortical breaches occurred between the ligamentous insertions in 85%. Lister's tubercle was not involved in 95% of the fractures. Three major fracture patterns emerged: radial styloid, dorsal, and volar. Each major pattern had two subtypes. Associated injuries were common. Scapholunate dissociation was associated with all types, not just the radial styloid fracture pattern. Conclusions The fracture patterns of two-part intraarticular fractures mostly involved the interligamentous zones. Three major groups were identified: dorsal, volar, and radial styloid. Lister's tubercle was preserved with fractures tending to propagate radial or ulnar to this structure. We suggest conceptualizing fracture fragments as osseo-ligamentous units to aid prediction of fracture patterns and associated injury. Study Design Diagnostic III Level of Evidence 3.