79 resultados para Surface wave methods
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
BACKGROUND: Propofol and sevoflurane display additivity for gamma-aminobutyric acid receptor activation, loss of consciousness, and tolerance of skin incision. Information about their interaction regarding electroencephalographic suppression is unavailable. This study examined this interaction as well as the interaction on the probability of tolerance of shake and shout and three noxious stimulations by using a response surface methodology. METHODS: Sixty patients preoperatively received different combined concentrations of propofol (0-12 microg/ml) and sevoflurane (0-3.5 vol.%) according to a crisscross design (274 concentration pairs, 3 to 6 per patient). After having reached pseudo-steady state, the authors recorded bispectral index, state and response entropy and the response to shake and shout, tetanic stimulation, laryngeal mask airway insertion, and laryngoscopy. For the analysis of the probability of tolerance by logistic regression, a Greco interaction model was used. For the separate analysis of bispectral index, state and response entropy suppression, a fractional Emax Greco model was used. All calculations were performed with NONMEM V (GloboMax LLC, Hanover, MD). RESULTS: Additivity was found for all endpoints, the Ce(50, PROP)/Ce(50, SEVO) for bispectral index suppression was 3.68 microg. ml(-1)/ 1.53 vol.%, for tolerance of shake and shout 2.34 microg . ml(-1)/ 1.03 vol.%, tetanic stimulation 5.34 microg . ml(-1)/ 2.11 vol.%, laryngeal mask airway insertion 5.92 microg. ml(-1) / 2.55 vol.%, and laryngoscopy 6.55 microg. ml(-1)/2.83 vol.%. CONCLUSION: For both electroencephalographic suppression and tolerance to stimulation, the interaction of propofol and sevoflurane was identified as additive. The response surface data can be used for more rational dose finding in case of sequential and coadministration of propofol and sevoflurane.
Resumo:
OBJECTIVES
To test the applicability, accuracy, precision, and reproducibility of various 3D superimposition techniques for radiographic data, transformed to triangulated surface data.
METHODS
Five superimposition techniques (3P: three-point registration; AC: anterior cranial base; AC + F: anterior cranial base + foramen magnum; BZ: both zygomatic arches; 1Z: one zygomatic arch) were tested using eight pairs of pre-existing CT data (pre- and post-treatment). These were obtained from non-growing orthodontic patients treated with rapid maxillary expansion. All datasets were superimposed by three operators independently, who repeated the whole procedure one month later. Accuracy was assessed by the distance (D) between superimposed datasets on three form-stable anatomical areas, located on the anterior cranial base and the foramen magnum. Precision and reproducibility were assessed using the distances between models at four specific landmarks. Non parametric multivariate models and Bland-Altman difference plots were used for analyses.
RESULTS
There was no difference among operators or between time points on the accuracy of each superimposition technique (p>0.05). The AC + F technique was the most accurate (D<0.17 mm), as expected, followed by AC and BZ superimpositions that presented similar level of accuracy (D<0.5 mm). 3P and 1Z were the least accurate superimpositions (0.79
Resumo:
INTRODUCTION Recording of muscle velocity recovery cycles (MVRCs) has been developed as a technique to investigate the pathophysiology of muscle diseases. MVRCs have been measured by direct muscle stimulation and concentric electromyographic needle recording. This study was undertaken to determine whether recordings can be made with surface electrodes. METHODS MVRCs with 1 and 2 conditioning stimuli were recorded simultaneously with concentric needle and surface electrodes from the brachioradialis muscle in 12 healthy volunteers. Muscle relative refractory period, early and late supernormality, and extra-late supernormality were compared between the recording techniques. RESULTS Surface recordings were possible in all subjects. The multifiber action potentials recorded with surface electrodes were smaller than those recorded with needles, but there was no significant difference between any of their MVRC properties. CONCLUSIONS MVRCs can be recorded with surface electrodes in healthy subjects. The use of surface electrodes may facilitate the technique of recording MVRCs. Muscle Nerve 53: 205-208, 2016.
Resumo:
BACKGROUND: A complete remission is essential for prolonging survival in patients with acute myeloid leukemia (AML). Daunorubicin is a cornerstone of the induction regimen, but the optimal dose is unknown. In older patients, it is usual to give daunorubicin at a dose of 45 to 50 mg per square meter of body-surface area. METHODS: Patients in whom AML or high-risk refractory anemia had been newly diagnosed and who were 60 to 83 years of age (median, 67) were randomly assigned to receive cytarabine, at a dose of 200 mg per square meter by continuous infusion for 7 days, plus daunorubicin for 3 days, either at the conventional dose of 45 mg per square meter (411 patients) or at an escalated dose of 90 mg per square meter (402 patients); this treatment was followed by a second cycle of cytarabine at a dose of 1000 mg per square meter every 12 hours [DOSAGE ERROR CORRECTED] for 6 days. The primary end point was event-free survival. RESULTS: The complete remission rates were 64% in the group that received the escalated dose of daunorubicin and 54% in the group that received the conventional dose (P=0.002); the rates of remission after the first cycle of induction treatment were 52% and 35%, respectively (P<0.001). There was no significant difference between the two groups in the incidence of hematologic toxic effects, 30-day mortality (11% and 12% in the two groups, respectively), or the incidence of moderate, severe, or life-threatening adverse events (P=0.08). Survival end points in the two groups did not differ significantly overall, but patients in the escalated-treatment group who were 60 to 65 years of age, as compared with the patients in the same age group who received the conventional dose, had higher rates of complete remission (73% vs. 51%), event-free survival (29% vs. 14%), and overall survival (38% vs. 23%). CONCLUSIONS: In patients with AML who are older than 60 years of age, escalation of the dose of daunorubicin to twice the conventional dose, with the entire dose administered in the first induction cycle, effects a more rapid response and a higher response rate than does the conventional dose, without additional toxic effects. (Current Controlled Trials number, ISRCTN77039377; and Netherlands National Trial Register number, NTR212.)
Resumo:
OBJECTIVE In susceptibility-weighted imaging (SWI) in the normal brain, cortical veins appear hypointense due to paramagnetic properties of deoxy-hemoglobin. Global cerebral anoxia decreases cerebral oxygen metabolism, thereby increasing oxy-hemoglobin levels in cerebral veins. We hypothesized that a lower cerebral oxygen extraction fraction in comatose patients with non-neonatal hypoxic ischemic encephalopathy (IHE) produce a pattern of global rarefied or pseudo-diminished cortical veins due to higher oxy-hemoglobin. PURPOSE 1. To investigate the topographic relationship between susceptibility effects in cortical veins and related diffusion restrictions on diffusion-weighted imaging (DWI) in patients with IHE. 2. To relate imaging findings to patterns of altered resting activity on surface EEG. METHODS Twenty-three IHE patients underwent MRI. EEG patterns were used to classify the depth of coma. Regional vs. global susceptibility changes on SWI and patterns of DWI restrictions were compared with the depth of coma. RESULTS All patients exhibited areas of restricted cortical diffusion and SWI abnormalities. The dominant DWI restrictions encompassed widespread areas along the precuneus, frontal and parietal association cortices and basal ganglia. For SWI, nineteen patients had generalized bi-hemispherical patterns, the EEG patterns correlated with coma grades III to V. Four patients had focal decreases of deoxy-hemoglobin following DWI restrictions; associated with normal EEGs. CONCLUSION Focal patterns of diamagnetic effects on SWI according to relative decreases in deoxy-hemoglobin due to reduced metabolic demand are associated with normal EEG in IHE patients. Global patterns indicated increased depth of coma and widespread cortical damage. CLINICAL RELEVANCE The results indicate a potential diagnostic value of SWI in patients with IHE.
Resumo:
This study evaluated the feasibility of documenting patterned injury using three dimensions and true colour photography without complex 3D surface documentation methods. This method is based on a generated 3D surface model using radiologic slice images (CT) while the colour information is derived from photographs taken with commercially available cameras. The external patterned injuries were documented in 16 cases using digital photography as well as highly precise photogrammetry-supported 3D structured light scanning. The internal findings of these deceased were recorded using CT and MRI. For registration of the internal with the external data, two different types of radiographic markers were used and compared. The 3D surface model generated from CT slice images was linked with the photographs, and thereby digital true-colour 3D models of the patterned injuries could be created (Image projection onto CT/IprojeCT). In addition, these external models were merged with the models of the somatic interior. We demonstrated that 3D documentation and visualization of external injury findings by integration of digital photography in CT/MRI data sets is suitable for the 3D documentation of individual patterned injuries to a body. Nevertheless, this documentation method is not a substitution for photogrammetry and surface scanning, especially when the entire bodily surface is to be recorded in three dimensions including all external findings, and when precise data is required for comparing highly detailed injury features with the injury-inflicting tool.
Resumo:
Aims. The OSIRIS camera onboard the Rosetta spacecraft obtained close-up views of the dust coma of comet 67P. The jet structures can be used to trace their source regions and to examine the possible effect of gas-surface interaction. Methods. We analyzed the wide-angle images obtained in the special dust observation sequences between August and September 2014. The jet features detected in different images were compared to study their time variability. The locations of the potential source regions of some of the jets are identified by ray tracing. We used a ring-masking technique to calculate the brightness distribution of dust jets along the projected distance. Results. The jets detected between August and September 2014 mostly originated in the Hapi region. Morphological changes appeared over a timescale of several days in September. The brightness slope of the dust jets is much steeper than the background coma. This might be related to the sublimation or fragmentation of the emitted dust grains. Interaction of the expanding gas flow with the cliff walls on both sides of Hapi could lead to erosion and material down-fall to the nucleus surface.
Resumo:
Fully controlled liquid injection and flow in hydrophobic polydimethylsiloxane (PDMS) two-dimensional microchannel arrays based on on-chip integrated, low-voltage-driven micropumps are demonstrated. Our architecture exploits the surface-acoustic-wave (SAW) induced counterflow mechanism and the effect of nebulization anisotropies at crossing areas owing to lateral propagating SAWs. We show that by selectively exciting single or multiple SAWs, fluids can be drawn from their reservoirs and moved towards selected positions of a microchannel grid. Splitting of the main liquid flow is also demonstrated by exploiting multiple SAW beams. As a demonstrator, we show simultaneous filling of two orthogonal microchannels. The present results show that SAW micropumps are good candidates for truly integrated on-chip fluidic networks allowing liquid control in arbitrarily shaped two-dimensional microchannel arrays.
Resumo:
This study evaluated the operator variability of different finishing and polishing techniques. After placing 120 composite restorations (Tetric EvoCeram) in plexiglassmolds, the surface of the specimens was roughened in a standardized manner. Twelve operators with different experience levels polished the specimens using the following finishing/polishing procedures: method 1 (40 ?m diamond [40D], 15 ?m diamond [15D], 42 ?m silicon carbide polisher [42S], 6 ?m silicon carbide polisher [6S] and Occlubrush [O]); method 2 (40D, 42S, 6S and O); method 3 (40D, 42S, 6S and PoGo); method 4 (40D, 42S and PoGo) and method 5 (40D, 42S and O). The mean surface roughness (Ra) was measured with a profilometer. Differences between the methods were analyzed with non-parametric ANOVA and pairwise Wilcoxon signed rank tests (?=0.05). All the restorations were qualitatively assessed using SEM. Methods 3 and 4 showed the best polishing results and method 5 demonstrated the poorest. Method 5 was also most dependent on the skills of the operator. Except for method 5, all of the tested procedures reached a clinically acceptable surface polish of Ra?0.2 ?m. Polishing procedures can be simplified without increasing variability between operators and without jeopardizing polishing results.
Resumo:
The examination of traffic accidents is daily routine in forensic medicine. An important question in the analysis of the victims of traffic accidents, for example in collisions between motor vehicles and pedestrians or cyclists, is the situation of the impact. Apart from forensic medical examinations (external examination and autopsy), three-dimensional technologies and methods are gaining importance in forensic investigations. Besides the post-mortem multi-slice computed tomography (MSCT) and magnetic resonance imaging (MRI) for the documentation and analysis of internal findings, highly precise 3D surface scanning is employed for the documentation of the external body findings and of injury-inflicting instruments. The correlation of injuries of the body to the injury-inflicting object and the accident mechanism are of great importance. The applied methods include documentation of the external and internal body and the involved vehicles and inflicting tools as well as the analysis of the acquired data. The body surface and the accident vehicles with their damages were digitized by 3D surface scanning. For the internal findings of the body, post-mortem MSCT and MRI were used. The analysis included the processing of the obtained data to 3D models, determination of the driving direction of the vehicle, correlation of injuries to the vehicle damages, geometric determination of the impact situation and evaluation of further findings of the accident. In the following article, the benefits of the 3D documentation and computer-assisted, drawn-to-scale 3D comparisons of the relevant injuries with the damages to the vehicle in the analysis of the course of accidents, especially with regard to the impact situation, are shown on two examined cases.
Resumo:
Phase-sensitive X-ray imaging shows a high sensitivity towards electron density variations, making it well suited for imaging of soft tissue matter. However, there are still open questions about the details of the image formation process. Here, a framework for numerical simulations of phase-sensitive X-ray imaging is presented, which takes both particle- and wave-like properties of X-rays into consideration. A split approach is presented where we combine a Monte Carlo method (MC) based sample part with a wave optics simulation based propagation part, leading to a framework that takes both particle- and wave-like properties into account. The framework can be adapted to different phase-sensitive imaging methods and has been validated through comparisons with experiments for grating interferometry and propagation-based imaging. The validation of the framework shows that the combination of wave optics and MC has been successfully implemented and yields good agreement between measurements and simulations. This demonstrates that the physical processes relevant for developing a deeper understanding of scattering in the context of phase-sensitive imaging are modelled in a sufficiently accurate manner. The framework can be used for the simulation of phase-sensitive X-ray imaging, for instance for the simulation of grating interferometry or propagation-based imaging.
Resumo:
Complexity has long been recognized and is increasingly becoming mainstream in geomorphology. However, the relative novelty of various concepts and techniques associated to it means that ambiguity continues to surround complexity. In this commentary, we present and discuss a variety of recent contributions that have the potential to help clarify issues and advance the use of complexity in geomorphology.
Resumo:
Polymers that are used in clinical practice as bone-defect-filling materials possess many essential qualities, such as moldability, mechanical strength and biodegradability, but they are neither osteoconductive nor osteoinductive. Osteoconductivity can be conferred by coating the material with a layer of calcium phosphate, which can be rendered osteoinductive by functionalizing it with an osteogenic agent. We wished to ascertain whether the morphological and physicochemical characteristics of unfunctionalized and bovine-serum-albumin (BSA)-functionalized calcium-phosphate coatings were influenced by the surface properties of polymeric carriers. The release kinetics of the protein were also investigated. Two sponge-like materials (Helistat® and Polyactive®) and two fibrous ones (Ethisorb and poly[lactic-co-glycolic acid]) were tested. The coating characteristics were evaluated using state-of-the-art methodologies. The release kinetics of BSA were monitored spectrophotometrically. The characteristics of the amorphous and the crystalline phases of the coatings were not influenced by either the surface chemistry or the surface geometry of the underlying polymer. The mechanism whereby BSA was incorporated into the crystalline layer and the rate of release of the truly incorporated depot were likewise unaffected by the nature of the polymeric carrier. Our biomimetic coating technique could be applied to either spongy or fibrous bone-defect-filling organic polymers, with a view to rendering them osteoconductive and osteoinductive.