18 resultados para Superficial roughness
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
We present assembly and application of an optical reflectometer for the analysis of dental erosion. The erosive procedure involved acid-induced softening and initial substance loss phases, which are considered to be difficult for visual diagnosis in a clinic. Change of the specular reflection signal showed the highest sensitivity for the detection of the early softening phase of erosion among tested methods. The exponential decrease of the specular reflection intensity with erosive duration was compared to the increase of enamel roughness. Surface roughness was measured by optical analysis, and the observed tendency was correlated with scanning electron microscopy images of eroded enamel. A high correlation between specular reflection intensity and measurement of enamel softening (r(2) ? -0.86) as well as calcium release (r(2) ? -0.86) was found during erosion progression. Measurement of diffuse reflection revealed higher tooth-to-tooth deviation in contrast to the analysis of specular reflection intensity and lower correlation with other applied methods (r(2) = 0.42-0.48). The proposed optical method allows simple and fast surface analysis and could be used for further optimization and construction of the first noncontact and cost-effective diagnostic tool for early erosion assessment in vivo.
Resumo:
Combined extended nerve and soft tissue defects of the upper extremity require nerve reconstruction and adequate soft tissue coverage. This study focuses on the reliability of the free vascularized sural nerve graft combined with a fasciocutaneous posterior calf flap within this indication. An anatomical study was performed on 26 cadaveric lower extremities that had been Thiel fixated and color silicone injected. Dissection of the fasciocutaneous posterior calf flap involved the medial sural nerve and superficial sural artery (SSA) with its septocutaneous perforators, extended laterally to include the lateral cutaneous branch of the sural nerve and continued to the popliteal origin of the vascular pedicle and the nerves. The vessel and nerves diameter were measured with an eyepiece reticle at 4.5× magnification. Length and diameter of the nerves and vessels were carefully assessed and reported in the dissection book. A total of 26 flaps were dissected. The SSA originated from the medial sural artery (13 cases), the popliteal artery (12 cases), or the lateral sural artery (one case). The average size of the SSA was 1.4 ± 0.4 mm. The mean pedicle length before the artery joined the sural nerve was 4.5 ± 1.9 cm. A comitant vein was present in 21 cases with an average diameter of 2.0 ± 0.8 mm, in 5 cases a separate vein needed to be dissected with an average diameter of 3.5 ± 0.4 mm. The mean medial vascularized sural nerve length was 21.2 ± 8.9 cm. Because of inclusion of the vascularized part of the lateral branch of the sural nerve (mean length of 16.7 ± 4.8 cm), a total of 35.0 ± 9.6 cm mean length of vascularized nerve could be gained from each extremity. The free vascularized sural nerve graft combined with a fasciocutaneous posterior calf flap pedicled on the SSA offers a reliable solution for complex tissue and nerve defect. Clin. Anat. 2012. © 2012 Wiley Periodicals, Inc.
Resumo:
SUMMARY The aim of this study was to evaluate the influence of surface roughness on surface hardness (Vickers; VHN), elastic modulus (EM), and flexural strength (FLS) of two computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic materials. One hundred sixty-two samples of VITABLOCS Mark II (VMII) and 162 samples of IPS Empress CAD (IPS) were ground according to six standardized protocols producing decreasing surface roughnesses (n=27/group): grinding with 1) silicon carbide (SiC) paper #80, 2) SiC paper #120, 3) SiC paper #220, 4) SiC paper #320, 5) SiC paper #500, and 6) SiC paper #1000. Surface roughness (Ra/Rz) was measured with a surface roughness meter, VHN and EM with a hardness indentation device, and FLS with a three-point bending test. To test for a correlation between surface roughness (Ra/Rz) and VHN, EM, or FLS, Spearman rank correlation coefficients were calculated. The decrease in surface roughness led to an increase in VHN from (VMII/IPS; medians) 263.7/256.5 VHN to 646.8/601.5 VHN, an increase in EM from 45.4/41.0 GPa to 66.8/58.4 GPa, and an increase in FLS from 49.5/44.3 MPa to 73.0/97.2 MPa. For both ceramic materials, Spearman rank correlation coefficients showed a strong negative correlation between surface roughness (Ra/Rz) and VHN or EM and a moderate negative correlation between Ra/Rz and FLS. In conclusion, a decrease in surface roughness generally improved the mechanical properties of the CAD/CAM ceramic materials tested. However, FLS was less influenced by surface roughness than expected.
Resumo:
OBJECTIVES: The objective of the study was to evaluate the efficacy of an additional usage of a diamond-coated curette on surface roughness, adhesion of periodontal ligament (PDL) fibroblasts, and of Streptococcus gordonii in vitro. MATERIALS AND METHODS: Test specimens were prepared from extracted teeth and exposed to instrumentation with conventional Gracey curettes with or without additional use of diamond-coated curettes. Surface roughness (Ra and Rz) was measured before and following treatment. In addition, the adhesion of PDL fibroblasts for 72 h and adhesion of S. gordonii ATCC 10558 for 2 h have been determined. RESULTS: Instrumentation with conventional Gracey curettes reduced surface roughness (median Ra before: 0.36 μm/after: 0.25 μm; p < 0.001; median Rz before: 2.34 μm/after: 1.61 μm; p < 0.001). The subsequent instrumentation with the diamond-coated curettes resulted in a median Ra of 0.31 μm/Rz of 2.06 μm (no significance in comparison to controls). The number of attached PDL fibroblasts did not change following scaling with Gracey curettes. The additional instrumentation with the diamond-coated curettes resulted in a two-fold increase in the number of attached PDL fibroblasts but not in the numbers of adhered bacteria. CONCLUSIONS: Treatment of root surfaces with conventional Gracey curettes followed by subsequent polishing with diamond-coated curettes may result in a root surface which provides favorable conditions for the attachment of PDL fibroblasts without enhancing microbial adhesion. CLINICAL RELEVANCE: The improved attachment of PDL fibroblasts and the limited microbial adhesion on root surfaces treated with scaling with conventional Gracey curettes followed by subsequent polishing with diamond-coated curettes may favor periodontal wound healing.
Resumo:
This study aims to evaluate the influence of different surface preparation techniques on long-term bonding effectiveness to eroded dentin.
Resumo:
Despite Duplex ultrasonography being a noninvasive, easily repeatable, readily available and economical tool, this examination and its normal ranges are rarely described in Moyamoya disease (MMD).
Resumo:
OBJECTIVE: To compare four different implantation modalities for the repair of superficial osteochondral defects in a caprine model using autologous, scaffold-free, engineered cartilage constructs, and to describe the short-term outcome of successfully implanted constructs. METHODS: Scaffold-free, autologous cartilage constructs were implanted within superficial osteochondral defects created in the stifle joints of nine adult goats. The implants were distributed between four 6-mm-diameter superficial osteochondral defects created in the trochlea femoris and secured in the defect using a covering periosteal flap (PF) alone or in combination with adhesives (platelet-rich plasma (PRP) or fibrin), or using PRP alone. Eight weeks after implantation surgery, the animals were killed. The defect sites were excised and subjected to macroscopic and histopathologic analyses. RESULTS: At 8 weeks, implants that had been held in place exclusively with a PF were well integrated both laterally and basally. The repair tissue manifested an architecture similar to that of hyaline articular cartilage. However, most of the implants that had been glued in place in the absence of a PF were lost during the initial 4-week phase of restricted joint movement. The use of human fibrin glue (FG) led to massive cell infiltration of the subchondral bone. CONCLUSIONS: The implantation of autologous, scaffold-free, engineered cartilage constructs might best be performed beneath a PF without the use of tissue adhesives. Successfully implanted constructs showed hyaline-like characteristics in adult goats within 2 months. Long-term animal studies and pilot clinical trials are now needed to evaluate the efficacy of this treatment strategy.
Resumo:
BACKGROUND: Peri-implantitis is associated with the presence of submarginal plaque, soft-tissue inflammation and advanced breakdown of the supporting bone. The progression of peri-implantitis following varying periods of continuing plaque accumulation has been studied in animal models. OBJECTIVE: The aim of the current experiment was to study the progression of peri-implantitis around implants with different surface roughness. MATERIAL AND METHODS: In five beagle dogs, three implants with either a sandblasted acid-etched surface (SLA) or a polished surface (P) were installed bilaterally in the edentulous premolar regions. After 3 months on a plaque control regimen, experimental peri-implantitis was induced by ligature placement and plaque accumulation was allowed to progress until about 40% of the height of the supporting bone had been lost. After this 4-month period, ligatures were removed and plaque accumulation was continued for an additional 5 months. Radiographs of all implant sites were obtained before and after 'active' experimental peri-implantitis as well as at the end of the experiment. Biopsies were harvested and the tissue samples were prepared for light microscopy. The sections were used for histometric and morphometric examinations. RESULTS: The radiographic examinations indicated that similar amounts of bone loss occurred at SLA and P sites during the active breakdown period, while the progression of bone loss was larger at SLA than at polished sites following ligature removal. The histological examination revealed that both bone loss and the size of the inflammatory lesion in the connective tissue were larger in SLA than in polished implant sites. The area of plaque was also larger at implants with an SLA surface than at implants with a polished surface. CONCLUSION: It is suggested that the progression of peri-implantitis, if left untreated, is more pronounced at implants with a moderately rough surface than at implants with a polished surface.
Resumo:
Objective-To evaluate pulsed-wave Doppler spectral parameters as a method for distinguishing between neoplastic and inflammatory peripheral lymphadenopathy in dogs. Sample Population-40 superficial lymph nodes from 33 dogs with peripheral lymphadenopathy. Procedures-3 Doppler spectral tracings were recorded from each node. Spectral Doppler analysis including assessment of the resistive index, peak systolic velocity-to-end diastolic velocity (S:D) ratio, diastolic notch velocity-to-peak systolic velocity (N:S) ratio, and end diastolic velocity-to-diastolic notch velocity ratio was performed for each tracing. Several calculation methods were used to determine the Doppler indices for each lymph node. After the ultrasonographic examination, fine needle aspirates or excisional biopsy specimens of the examined lymph nodes were obtained, and lymphadenopathy was classified as either inflammatory or neoplastic (lymphomatous or metastatic) via cytologic or histologic examination. Results of Doppler analysis were compared with cytologic or histopathologic findings. Results-The Doppler index with the highest diagnostic accuracy was the S:D ratio calculated from the first recorded tracing; a cutoff value of 3.22 yielded sensitivity of 91%, specificity of 100%, and negative predictive value of 89% for detection of neoplasia. Overall diagnostic accuracy was 95%. At a sensitivity of 100%, the most accurate index was the N:S ratio calculated from the first recorded tracing; a cutoff value of 0.45 yielded specificity of 67%, positive predictive value of 81%, and overall diagnostic accuracy of 86.5%. Conclusions and Clinical Relevance-Results suggested that noninvasive Doppler spectral analysis may be useful in the diagnosis of neoplastic versus inflammatory peripheral lymphadenopathy in dogs.
Resumo:
In this research the taxonomic structure of diatoms in sediments of high mountain lakes was studied. These lakes are located in Chile between 32°49' and 38°48' S in the Andean Cordillera. A total of 99 diatom taxa distributed in 48 genera were identified and all this taxa are cosmopolitan excepting a Eunotia andinofrequens, Gomphonema punae, Pinnularia araucanensis and Pinnularia acidicola, which are know only for the Southern Hemisphere. The assemblages of diatoms were different in the studied lakes. So the high mountain lakes Ocho, Huifa, Ensueño and Negra, dominated benthic diatoms which are typical of oligotrophic and acid waters as Achnanthidium exiguum, Achnanthidium minutissimum, Encyonema minutum, Pinnularia acidicola and Planothidium lanceolatum. In the assemblages from lakes Galletué, Icalma and Laja planktonic diatoms were more abundant, which are common in alkaline and mesotrophic waters, e.g., Asterionella formosa, Aulacoseira distans, Aulacoseira granulata, Cyclotella stelligera and Rhopalodia gibba.