12 resultados para Summation generator
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
We propose a novel methodology to generate realistic network flow traces to enable systematic evaluation of network monitoring systems in various traffic conditions. Our technique uses a graph-based approach to model the communication structure observed in real-world traces and to extract traffic templates. By combining extracted and user-defined traffic templates, realistic network flow traces that comprise normal traffic and customized conditions are generated in a scalable manner. A proof-of-concept implementation demonstrates the utility and simplicity of our method to produce a variety of evaluation scenarios. We show that the extraction of templates from real-world traffic leads to a manageable number of templates that still enable accurate re-creation of the original communication properties on the network flow level.
Resumo:
An improved chemical strategy for processing of the generator produced 68Ga was developed based on processing of the original 68Ge/68Ga generator eluate on a micro-column. Direct pre-concentration and purification of the eluted 68Ga is performed on a cation-exchange resin in hydrochloric acid/acetone media. A supplementary step based on a second micro-column filled with a second resin allows direct re-adsorption of 68Ga eluted from the cation exchanger. 68Ga is finally striped from the second resin with a small volume of pure water. For this purpose a strong anion exchanger and a novel extraction chromatographic resin based on tetraalkyldiglycolamides are characterized. The strategy allows online pre-concentration and purification of 68Ga from the original generator eluate. The supplementary column allows transferring 68Ga with high radionuclide and chemical quality in the aqueous solution with small volume and low acidity useful for direct radiolabeling reactions.
Resumo:
Energy-harvesting devices attract wide interest as power supplies of today's medical implants. Their long lifetime will spare patients from repeated surgical interventions. They also offer the opportunity to further miniaturize existing implants such as pacemakers, defibrillators or recorders of bio signals. A mass imbalance oscillation generator, which consists of a clockwork from a commercially available automatic wrist watch, was used as energy harvesting device to convert the kinetic energy from the cardiac wall motion to electrical energy. An MRI-based motion analysis of the left ventricle revealed basal regions to be energetically most favorable for the rotating unbalance of our harvester. A mathematical model was developed as a tool for optimizing the device's configuration. The model was validated by an in vitro experiment where an arm robot accelerated the harvesting device by reproducing the cardiac motion. Furthermore, in an in vivo experiment, the device was affixed onto a sheep heart for 1 h. The generated power in both experiments-in vitro (30 μW) and in vivo (16.7 μW)-is sufficient to power modern pacemakers.
Resumo:
OBJECTIVE: To evaluate and compare the antinociceptive effects of the three alpha-2 agonists, detomidine, romifidine and xylazine at doses considered equipotent for sedation, using the nociceptive withdrawal reflex (NWR) and temporal summation model in standing horses. STUDY DESIGN: Prospective, blinded, randomized cross-over study. ANIMALS: Ten healthy adult horses weighing 527-645 kg and aged 11-21 years old. METHODS: Electrical stimulation was applied to the digital nerves to evoke NWR and temporal summation in the left thoracic limb and pelvic limb of each horse. Electromyographic reflex activity was recorded from the common digital extensor and the cranial tibial muscles. After baseline measurements a single bolus dose of detomidine, 0.02 mg kg(-1), romifidine 0.08 mg kg(-1), or xylazine, 1 mg kg(-1), was administered intravenously (IV). Determinations of NWR and temporal summation thresholds were repeated at 10, 20, 30, 40, 60, 70, 90, 100, 120 and 130 minutes after test-drug administration alternating the thoracic limb and the pelvic limb. Depth of sedation was assessed before measurements at each time point. Behavioural reaction was observed and recorded following each stimulation. RESULTS: The administration of detomidine, romifidine and xylazine significantly increased the current intensities necessary to evoke NWR and temporal summation in thoracic limbs and pelvic limbs of all horses compared with baseline. Xylazine increased NWR thresholds over baseline values for 60 minutes, while detomidine and romifidine increased NWR thresholds over baseline for 100 and 120 minutes, respectively. Temporal summation thresholds were significantly increased for 40, 70 and 130 minutes after xylazine, detomidine and romifidine, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: Detomidine, romifidine and xylazine, administered IV at doses considered equipotent for sedation, significantly increased NWR and temporal summation thresholds, used as a measure of antinociceptive activity. The extent of maximal increase of NWR and temporal summation thresholds was comparable, while the duration of action was drug-specific.
Resumo:
A physical random number generator based on the intrinsic randomness of quantum mechanics is described. The random events are realized by the choice of single photons between the two outputs of a beamsplitter. We present a simple device, which minimizes the impact of the photon counters’ noise, dead-time and after pulses.
Resumo:
Objective To examine the influence of a low dose dexmedetomidine infusion on the nociceptive withdrawal reflex and temporal summation in dogs during isoflurane anaesthesia. Study design Prospective experimental blinded cross-over study. Animals Eight healthy mixed breed dogs, body weight Mean +/- SD 26.5 +/- 8.4 kg and age 25 +/- 16 months. Methods Anaesthesia was induced with propofol and maintained with isoflurane (Fe'ISO 1.3%) delivered in oxygen and air. After stabilization, baseline recordings (time 0) were obtained, then a dexmedetomidine bolus (1 mug kg(-1) IV) followed by a continuous rate infusion (1 mug kg(-1) hour(-1) ) or saline placebo were administered. At times 10, 30 and 60 minutes after the initial bolus, electrical stimulations of increasing intensity were applied over the lateral plantar digital nerve, and administered both as single and as repeated stimuli. The resulting reflex responses were recorded using electromyography. Data were analysed using a multivariable linear regression model and a Kruskal Wallis test for single stimulation data, and repeated measures anova and paired t-test for repeated stimulation data. Results The AUC for the stimulus-response curves after single stimulation were similar for both treatments at time 0. At times 10, 30 and 60 the AUCs for the stimulus-response curves were significantly lower with dexmedetomidine treatment than with placebo. Temporal summation was evident in both treatments at times 0, 10, 30 and 60 starting from a stimulation intensity of 10 mA. The magnitude of temporal summation was smaller in dexmedetomidine than in placebo treated dogs at time 10, 30 and 60, but not at time 0. Conclusions During isoflurane anaesthesia, low dose dexmedetomidine suppresses the nociceptive reflex responses after single and repeated electrical stimulation. Clinical relevance This experimental study confirms previous reports on its peri-operative efficacy under clinical conditions, and further indicates that dexmedetomidine might reduce the risk of post-operative chronic pain development.
Resumo:
As the complexity of active medical implants increases, the task of embedding a life-long power supply at the time of implantation becomes more challenging. A periodic renewal of the energy source is often required. Human energy harvesting is, therefore, seen as a possible remedy. In this paper, we present a novel idea to harvest energy from the pressure-driven deformation of an artery by the principle of magneto-hydrodynamics. The generator relies on a highly electrically conductive fluid accelerated perpendicularly to a magnetic field by means of an efficient lever arm mechanism. An artery with 10 mm inner diameter is chosen as a potential implantation site and its ability to drive the generator is established. Three analytical models are proposed to investigate the relevant design parameters and to determine the existence of an optimal configuration. The predicted output power reaches 65 μW according to the first two models and 135 μW according to the third model. It is found that the generator, designed as a circular structure encompassing the artery, should not exceed a total volume of 3 cm3.
Resumo:
Ventricular assist devices (VADs) are blood pumps that offer an option to support the circulation of patients with severe heart failure. Since a failing heart has a remaining pump function, its interaction with the VAD influences the hemodynamics. Ideally, the heart's action is taken into account for actuating the device such that the device is synchronized to the natural cardiac cycle. To realize this in practice, a reliable real-time algorithm for the automatic synchronization of the VAD to the heart rate is required. This paper defines the tasks such an algorithm needs to fulfill: the automatic detection of irregular heart beats and the feedback control of the phase shift between the systolic phases of the heart and the assist device. We demonstrate a possible solution to these problems and analyze its performance in two steps. First, the algorithm is tested using the MIT-BIH arrhythmia database. Second, the algorithm is implemented in a controller for a pulsatile and a continuous-flow VAD. These devices are connected to a hybrid mock circulation where three test scenarios are evaluated. The proposed algorithm ensures a reliable synchronization of the VAD to the heart cycle, while being insensitive to irregularities in the heart rate.
Resumo:
Replacement intervals of implantable medical devices are commonly dictated by battery life. Therefore, intracorporeal energy harvesting has the potential to reduce the number of surgical interventions by extending the life cycle of active devices. Given the accumulated experience with intravascular devices such as stents, heart valves, and cardiac assist devices, the idea to harvest a small fraction of the hydraulic energy available in the cardiovascular circulation is revisited. The aim of this article is to explore the technical feasibility of harvesting 1 mW electric power using a miniature hydrodynamic turbine powered by about 1% of the cardiac output flow in a peripheral artery. To this end, numerical modelling of the fluid mechanics and experimental verification of the overall performance of a 1:1 scale friction turbine are performed in vitro. The numerical flow model is validated for a range of turbine configurations and flow conditions (up to 250 mL/min) in terms of hydromechanic efficiency; up to 15% could be achieved with the nonoptimized configurations of the study. Although this article does not entail the clinical feasibility of intravascular turbines in terms of hemocompatibility and impact on the circulatory system, the numerical model does provide first estimates of the mechanical shear forces relevant to blood trauma and platelet activation. It is concluded that the time-integrated shear stress exposure is significantly lower than in cardiac assist devices due to lower flow velocities and predominantly laminar flow.
Resumo:
BACKGROUND Cold atmospheric plasma (CAP, i.e. ionized air) is an innovating promising tool in reducing bacteria. OBJECTIVE We conducted the first clinical trial with the novel PlasmaDerm(®) VU-2010 device to assess safety and, as secondary endpoints, efficacy and applicability of 45 s/cm(2) cold atmospheric plasma as add-on therapy against chronic venous leg ulcers. METHODS From April 2011 to April 2012, 14 patients were randomized to receive standardized modern wound care (n = 7) or plasma in addition to standard care (n = 7) 3× per week for 8 weeks. The ulcer size was determined weekly (Visitrak(®) , photodocumentation). Bacterial load (bacterial swabs, contact agar plates) and pain during and between treatments (visual analogue scales) were assessed. Patients and doctors rated the applicability of plasma (questionnaires). RESULTS The plasma treatment was safe with 2 SAEs and 77 AEs approximately equally distributed among both groups (P = 0.77 and P = 1.0, Fisher's exact test). Two AEs probably related to plasma. Plasma treatment resulted in a significant reduction in lesional bacterial load (P = 0.04, Wilcoxon signed-rank test). A more than 50% ulcer size reduction was noted in 5/7 and 4/7 patients in the standard and plasma groups, respectively, and a greater size reduction occurred in the plasma group (plasma -5.3 cm(2) , standard: -3.4 cm(2) ) (non-significant, P = 0.42, log-rank test). The only ulcer that closed after 7 weeks received plasma. Patients in the plasma group quoted less pain compared to the control group. The plasma applicability was not rated inferior to standard wound care (P = 0.94, Wilcoxon-Mann-Whitney test). Physicians would recommend (P = 0.06, Wilcoxon-Mann-Whitney test) or repeat (P = 0.08, Wilcoxon-Mann-Whitney test) plasma treatment by trend. CONCLUSION Cold atmospheric plasma displays favourable antibacterial effects. We demonstrated that plasma treatment with the PlasmaDerm(®) VU-2010 device is safe and effective in patients with chronic venous leg ulcers. Thus, larger controlled trials and the development of devices with larger application surfaces are warranted.
Resumo:
The nociceptive withdrawal reflex (NWR) model is used in animal pain research to quantify nociception. The aim of this study was to evaluate the NWR evoked by repeated stimulations in healthy, non-medicated standing sheep. Repeated electrical stimulations were applied at 5Hz for 2s to the digital nerves of the right thoracic and the pelvic limbs of 25 standing sheep. The stimulation intensities applied were fractions (0.5, 0.6, 0.7, 0.8, 0.9 and 1) of the individual previously determined nociceptive threshold (It) after single stimulation. Surface-electromyographic activity (EMG) was recorded from the deltoid, the femoral biceps or the peroneus tertius muscles. The repeated stimulation threshold (RS It) was reached if at least one stimulus in the train was followed by a reflex with a minimal root-mean-square-amplitude (RMSA) of 20μV. The behavioural reaction following each series of stimulations was scored on a scale from 0 (no reaction) to 5 (vigorous whole-body reaction). For the deltoid muscle, RS It was 2.3mA (1.6-3mA) with a reaction score of 2 (1-2) and at a fraction of 0.6 (0.5-0.8)×It. For the biceps femoris muscle, RS It was 2.9mA (2.6-4mA) with a reaction score of 1 (1-2) at a fraction of and 0.55 (0.4-0.7)×It while for the peroneus tertius muscle RS It was 3mA (2.8-3.5mA) with a reaction score of 1 (1-2) and at a fraction of 0.8 (0.8-0.95)×It. Both, RMSA and reaction scores increased significantly with increasing stimulation intensities in all muscles (p<0.001). The repeated application of electrical stimuli led to temporal summation of nociceptive inputs and therefore a reduction of the stimulus intensity evoking a withdrawal reaction in healthy, standing sheep. Data achieved in this study can now serve as reference for further clinical or experimental applications of the model in this species.
Resumo:
An autonomous energy source within a human body is of key importance in the development of medical implants. This work deals with the modelling and the validation of an energy harvesting device which converts the myocardial contractions into electrical energy. The mechanism consists of a clockwork from a commercially available wrist watch. We developed a physical model which is able to predict the total amount of energy generated when applying an external excitation. For the validation of the model, a custom-made hexapod robot was used to accelerate the harvesting device along a given trajectory. We applied forward kinematics to determine the actual motion experienced by the harvesting device. The motion provides translational as well as rotational motion information for accurate simulations in three-dimensional space. The physical model could be successfully validated.