64 resultados para Sulfate minerals
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
The bulk magnetic mineral record from Lake Ohrid, spanning the past 637 kyr, reflects large-scale shifts in hydrological conditions, and, superimposed, a strong signal of environmental conditions on glacial–interglacial and millennial timescales. A shift in the formation of early diagenetic ferrimagnetic iron sulfides to siderites is observed around 320 ka. This change is probably associated with variable availability of sulfide in the pore water. We propose that sulfate concentrations were significantly higher before ∼ 320 ka, due to either a higher sulfate flux or lower dilution of lake sulfate due to a smaller water volume. Diagenetic iron minerals appear more abundant during glacials, which are generally characterized by higher Fe / Ca ratios in the sediments. While in the lower part of the core the ferrimagnetic sulfide signal overprints the primary detrital magnetic signal, the upper part of the core is dominated by variable proportions of high- to low-coercivity iron oxides. Glacial sediments are characterized by high concentration of high-coercivity magnetic minerals (hematite, goethite), which relate to enhanced erosion of soils that had formed during preceding interglacials. Superimposed on the glacial–interglacial behavior are millennial-scale oscillations in the magnetic mineral composition that parallel variations in summer insolation. Like the processes on glacial–interglacial timescales, low summer insolation and a retreat in vegetation resulted in enhanced erosion of soil material. Our study highlights that rock-magnetic studies, in concert with geochemical and sedimentological investigations, provide a multi-level contribution to environmental reconstructions, since the magnetic properties can mirror both environmental conditions on land and intra-lake processes.
Resumo:
NK cells express toll-like receptors (TLR) that recognize conserved pathogen or damage associated molecular patterns and play a fundamental role in innate immunity. Low molecular weight dextran sulfate (DXS), known to inhibit the complement system, has recently been reported by us to inhibit TLR4-induced maturation of human monocyte-derived dendritic cells (MoDC). In this study, we investigated the capability of DXS to interfere with human NK cell activation triggered directly by TLR2 agonists or indirectly by supernatants of TLR4-activated MoDC. Both TLR2 agonists and supernatants of TLR4-activated MoDC activated NK cells phenotypically, as demonstrated by the analysis of NK cell activation markers (CD56, CD25, CD69, NKp30, NKp44, NKp46, DNAM-1 and NKG2D), and functionally as shown by increased NK cell degranulation (CD107a surface expression) and IFN-gamma secretion. DXS prevented the up-regulation of NK cell activation markers triggered by TLR2 ligands or supernatants of TLR4-activated MoDC and dose-dependently abrogated NK cell degranulation and IFN-gamma secretion. In summary our results suggest that DXS may be a useful reagent to inhibit the direct and indirect TLR-mediated activation of NK cells.
Resumo:
Desulfovibrio sp. A2 is an anaerobic gram-negative sulfate-reducing bacterium with remarkable tolerance to copper. It was isolated from wastewater effluents of a zinc smelter at the Urals. Here, we report the 4.2-Mb draft genome sequence of Desulfovibrio sp. A2 and identify potential copper resistance mechanisms.
Resumo:
We have sequenced the genome of Desulfosporosinus sp. OT, a Gram-positive, acidophilic sulfate-reducing Firmicute isolated from copper tailing sediment in the Norilsk mining-smelting area in Northern Siberia, Russia. This represents the first sequenced genome of a Desulfosporosinus species. The genome has a size of 5.7 Mb and encodes 6,222 putative proteins.
Resumo:
Homeopathic preparations are used in homeopathy and anthroposophic medicine. Although there is evidence of effectiveness in several clinical studies, including double-blinded randomized controlled trials, their nature and mode of action could not be explained with current scientific approaches yet. Several physical methods have already been applied to investigate homeopathic preparations but it is yet unclear which methods are best suited to identify characteristic physicochemical properties of homeopathic preparations. The aim of this study was to investigate homeopathic preparations with UV-spectroscopy. In a blinded, randomized, controlled experiment homeopathic preparations of copper sulfate (CuSO(4); 11c-30c), quartz (SiO(2); 10c-30c, i.e., centesimal dilution steps) and sulfur (S; 11×-30×, i.e., decimal dilution steps) and controls (one-time succussed diluent) were investigated using UV-spectroscopy and tested for contamination by inductively coupled plasma mass spectrometry (ICP-MS). The UV transmission for homeopathic preparations of CuSO(4) preparations was significantly lower than in controls. The transmission seemed to be also lower for both SiO(2) and S, but not significant. The mean effect size (95% confidence interval) was similar for the homeopathic preparations: CuSO(4) (pooled data) 0.0544% (0.0260-0.0827%), SiO(2) 0.0323% (-0.0064% to 0.0710%) and S 0.0281% (-0.0520% to 0.1082%). UV transmission values of homeopathic preparations had a significantly higher variability compared to controls. In none of the samples the concentration of any element analyzed by ICP-MS exceeded 100 ppb. Lower transmission of UV light may indicate that homeopathic preparations are less structured or more dynamic than their succussed pure solvent.
Resumo:
Intracoronary administration of glycosaminoglycan analogs, including the complement inhibitor dextran sulfate, attenuates myocardial ischemia/reperfusion injury (I/R injury). However, dextran sulfate has a distinct anticoagulatory effect, possibly limiting its use in specific situations in vivo. We therefore developed multimeric tyrosine sulfate (sTyr-PAA), a novel, minimally anticoagulatory, fully synthetic non-carbohydrate-containing polyacrylamide conjugate, for in vivo testing in an acute closed-chest porcine model of acute myocardial infarction.
Resumo:
CZE coupled to sheath liquid-based electrospray ionization (ESI) and multiple-stage ion trap mass spectrometry (MS(n) ) was used for the confirmation analysis of ethyl glucuronide (EtG) and ethyl sulfate (EtS) in human serum and urine collected after intake of alcoholic beverages. Electrophoretic separations were performed in uncoated fused-silica capillaries using a pH 9.5 ammonium acetate background electrolyte and normal polarity. MS detection of EtG and EtS occurred after negative ionization using a spray liquid containing 0.5% v/v ammonia in isopropanol/water (60:40%, v/v). CZE-MS and CZE-MS² results obtained after injection of solid-phase extracts for EtG and EtS and of diluted urine confirmed the presence of EtG and EtS in samples whose levels were previously determined by CZE with indirect UV detection. Detection limits of each compound were estimated to be around 2.0 (injection of diluted urine) and 0.2 μg/mL (extracts).
Resumo:
Dialysate regeneration by sorbents is an alternative to conventional single-pass dialysis. Little is known about the capacity of sorbents to clear dialysate of “middle molecules” and protein-bound uremic toxins. We studied p-cresol sulfate (PCS) and β-2-microglobulin (β2M) removal from dialysate by a sorbent: 1. PCS (40 mg PCS dissolved in 4 L of fresh dialysate) was recirculated through a sorbent cartridge (SORB Technology, Inc.) for analysis of PCS removal. 2. Spent peritoneal dialysate was recirculated on the “blood” side of a high-flux dialyzer. On the “dialysate” side of the membrane, bicarbonate dialysate was recirculated through a sorbent cartridge. β2M was measured in both streams. Two results are of particular importance for the use of regenerated fluid in chronic dialysis: 1. PCS was virtually completely removed from the dialysate. On average, PCS concentration was reduced to 1.4% of the starting concentration after 60 minutes. PCS extraction across the sorbent was nearly complete at any time. 2. β2M was on average reduced to 14.3% of the starting concentration after 60 minutes. Postsorbent concentrations were consistently below the validated range of the test method. We conclude that PCS and β2M are efficiently removed from the dialysate by commercially available sorbent technology. Spent peritoneal dialysis fluid can be cleared of β2M when circulated against sorbent-regenerated dialysate using a high-flux membrane.