10 resultados para Stable anode performance
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Knowledge of the fate of deposited N in the possibly N-limited, highly biodiverse north Andean forests is important because of the possible effects of N inputs on plant performance and species composition. We analyzed concentrations and fluxes of NO3 −–N, NH4 +–N and dissolved organic N (DON) in rainfall, throughfall, litter leachate, mineral soil solutions (0.15–0.30 m depths) and stream water in a montane forest in Ecuador during four consecutive quarters and used the natural 15N abundance in NO3 − during the passage of rain water through the ecosystem and bulk δ15N values in soil to detect N transformations. Depletion of 15N in NO3 − and increased NO3 −–N fluxes during the passage through the canopy and the organic layer indicated nitrification in these compartments. During leaching from the organic layer to mineral soil and stream, NO3 − concentrations progressively decreased and were enriched in 15N but did not reach the δ15N values of solid phase organic matter (δ15N = 5.6–6.7‰). This suggested a combination of nitrification and denitrification in mineral soil. In the wettest quarter, the δ15N value of NO3 − in litter leachate was smaller (δ15N = −1.58‰) than in the other quarters (δ15N = −9.38 ± SE 0.46‰) probably because of reduced mineralization and associated fractionation against 15N. Nitrogen isotope fractionation of NO3 − between litter leachate and stream water was smaller in the wettest period than in the other periods probably because of a higher rate of denitrification and continuous dilution by isotopically lighter NO3 −–N from throughfall and nitrification in the organic layer during the wettest period. The stable N isotope composition of NO3 − gave valuable indications of N transformations during the passage of water through the forest ecosystem from rainfall to the stream.
Resumo:
PURPOSE: There is a need for valid and reliable short scales that can be used to assess social networks and social supports and to screen for social isolation in older persons. DESIGN AND METHODS: The present study is a cross-national and cross-cultural evaluation of the performance of an abbreviated version of the Lubben Social Network Scale (LSNS-6), which was used to screen for social isolation among community-dwelling older adult populations in three European countries. Based on the concept of lack of redundancy of social ties we defined clinical cut-points of the LSNS-6 for identifying persons deemed at risk for social isolation. RESULTS: Among all three samples, the LSNS-6 and two subscales (Family and Friends) demonstrated high levels of internal consistency, stable factor structures, and high correlations with criterion variables. The proposed clinical cut-points showed good convergent validity, and classified 20% of the respondents in Hamburg, 11% of those in Solothurn (Switzerland), and 15% of those in London as at risk for social isolation. IMPLICATIONS: We conclude that abbreviated scales such as the LSNS-6 should be considered for inclusion in practice protocols of gerontological practitioners. Screening older persons based on the LSNS-6 provides quantitative information on their family and friendship ties, and identifies persons at increased risk for social isolation who might benefit from in-depth assessment and targeted interventions.
Resumo:
OBJECTIVES: The aim of this prospective study was to evaluate the 5-year performance and success rate of titanium screw-type implants with the titanium plasma spray (TPS) or the sand-blasted, large grit, acid-etched (SLA) surface inserted in a two-stage sinus floor elevation (SFE) procedure in the posterior maxilla. MATERIAL AND METHODS: A total of 59 delayed SFEs were performed in 56 patients between January 1997 and December 2001, using a composite graft with autogenous bone chips combined with deproteinized bovine bone mineral (DBBM) or synthetic porous beta-tricalcium phosphate (beta-TCP). After a healing period averaging 7.75 months, 111 dental implants were inserted. After an additional 8-14-week healing period, all implants were functionally loaded with cemented crowns or fixed partial dentures. The patients were recalled at 12 and 60 months for clinical and radiographic examination. RESULTS: One patient developed an acute infection in the right maxillary sinus after SFE and did not undergo implant therapy. Two of the 111 inserted implants had to be removed because of a developing atypical facial pain, and 11 implants were lost to follow-up and were considered drop-outs. The remaining 98 implants showed favorable clinical and radiographic findings at the 5-year examination. The peri-implant soft tissues were stable over time; the mean probing depths and mean attachment levels did not change during the follow-up period. The measurement of the bone crest levels (DIB values) indicated stability as well. Based on strict success criteria, all 98 implants were considered successfully integrated, resulting in a 5-year success rate of 98% (for TPS implants 89%, for SLA implants 100%). CONCLUSION: This prospective study assessing the performance of dental implants inserted after SFE demonstrated that titanium implants can achieve and maintain successful tissue integration with high predictability for at least 5 years of follow-up in carefully selected patients.
Resumo:
Every year around 100 million male piglets are castrated in the EU, usually without anaesthesia or post-operative analgesia. This surgical intervention is painful and stressful. Several main players within the pig industry have voluntarily agreed to end the practice of surgical pig castration in the EU by 2018. One alternative to castration is entire male pig production. However, entire males behave differently than castrates, for example, by performing more mounting behaviour, which is suggested to be a welfare problem. The aim of our study was to develop a comprehensive ethogram of different types of mounting and to investigate properties, causes and consequences of mounting behaviour in finishing pigs. The study included 80 entire male and 80 female pigs from two farrowing batches born six weeks apart. Mixed sex and single-sex housing of pigs are both common in pig farming, so to ensure our study was representative, the 160 pigs were assigned to social groups of 20 in three treatments: entire male pigs only (MM, 2 groups, n = 40), entire females only (FF, 2 groups, n = 40) and entire males and females mixed together (MF, 4 groups, n = 80). Measurements took place during the final six weeks before slaughter (between 63.5 and 105.5 kg). Observations of mounting behaviour on 12 days per batch suggested that: (i) males mounted more than females, (ii) within sex, there was no effect of treatment on the amount of mounting (although the statistical power of the study to detect these effects was low), and (iii) there were individual differences in mounting that were stable over time (within sex). Classification of mounting into different categories revealed that sexual mounting was most common overall and in males but only rare in females. Compared to other types of mounting (e.g. caused by crowding or during a fight), sexual mounts lasted longer and provoked more screaming by the recipient. There were no relationships between mounting behaviour on the one hand and dominance rank in food competition tests, the circulating levels of sex hormones (oestradiol, testosterone and progesterone) at the end of the study, the health scores (lameness and scratches) or weight gain on the other hand. The stable individual differences of mounting over time suggest that mounting behaviour is a trait of the individual rather than the appearance of random outbreaks. However, these differences in mounting cannot be explained by dominance behaviour or by differences in sex hormone concentrations that could indicate the onset of puberty. Mounting behaviour and in particular sexual mounting provoked high pitched screaming of the recipients indicating that mounting is a welfare problem. For the welfare assessment of entire male pig production the performance of mounting behaviour should be considered. (C) 2013 Elsevier B.V. All rights reserved.
Resumo:
Key performance features of a miniature laser ablation time-of-flight mass spectrometer designed for in situ investigations of the chemical composition of planetary surfaces are presented. This mass spectrometer is well suited for elemental and isotopic analysis of raw solid materials with high sensitivity and high spatial resolution. In this study, ultraviolet laser radiation with irradiances suitable for ablation (< 1 GW/cm2) is used to achieve stable ion formation and low sample consumption. In comparison to our previous laser ablation studies at infrared wavelengths, several improvements to the experimental setup have been made, which allow accurate control over the experimental conditions and good reproducibility of measurements. Current performance evaluations indicate significant improvements to several instrumental figures of merit. Calibration of the mass scale is performed within a mass accuracy (Δm/m) in the range of 100 ppm, and a typical mass resolution (m/Δm) ~600 is achieved at the lead mass peaks. At lower laser irradiances, the mass resolution is better, about (m/Δm) ~900 for lead, and limited by the laser pulse duration of 3 ns. The effective dynamic range of the instrument was enhanced from about 6 decades determined in previous study up to more than 8 decades at present. Current studies show high sensitivity in detection of both metallic and non-metallic elements. Their abundance down to tens of ppb can be measured together with their isotopic patterns. Due to strict control of the experimental parameters, e.g. laser characteristics, ion-optical parameters and sample position, by computer control, measurements can be performed with high reproducibility. Copyright © 2012 John Wiley & Sons, Ltd.
Resumo:
This paper presents the application of a variety of techniques to study jet substructure. The performance of various modified jet algorithms, or jet grooming techniques, for several jet types and event topologies is investigated for jets with transverse momentum larger than 300 GeV. Properties of jets subjected to the mass-drop filtering, trimming, and pruning algorithms are found to have reduced sensitivity to multiple proton-proton interactions, are more stable at high luminosity and improve the physics potential of searches for heavy boosted objects. Studies of the expected discrimination power of jet mass and jet substructure observables in searches for new physics are also presented. Event samples enriched in boosted W and Z bosons and top-quark pairs are used to study both the individual jet invariant mass scales and the efficacy of algorithms to tag boosted hadronic objects. The analyses presented use the full 2011 ATLAS dataset, corresponding to an integrated luminosity of 4.7 +/- 0.1 /fb from proton-proton collisions produced by the Large Hadron Collider at a center-of-mass energy of sqrt(s) = 7 TeV.
Resumo:
OBJECTIVES Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. METHODS The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. RESULTS Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. CONCLUSIONS We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion.
Resumo:
Whole exome sequencing (WES) is increasingly used in research and diagnostics. WES users expect coverage of the entire coding region of known genes as well as sufficient read depth for the covered regions. It is, however, unknown which recent WES platform is most suitable to meet these expectations. We present insights into the performance of the most recent standard exome enrichment platforms from Agilent, NimbleGen and Illumina applied to six different DNA samples by two sequencing vendors per platform. Our results suggest that both Agilent and NimbleGen overall perform better than Illumina and that the high enrichment performance of Agilent is stable among samples and between vendors, whereas NimbleGen is only able to achieve vendor- and sample-specific best exome coverage. Moreover, the recent Agilent platform overall captures more coding exons with sufficient read depth than NimbleGen and Illumina. Due to considerable gaps in effective exome coverage, however, the three platforms cannot capture all known coding exons alone or in combination, requiring improvement. Our data emphasize the importance of evaluation of updated platform versions and suggest that enrichment-free whole genome sequencing can overcome the limitations of WES in sufficiently covering coding exons, especially GC-rich regions, and in characterizing structural variants.
Resumo:
Gebiet: Chirurgie Biomedizintechnik Biophysik Transplantationsmedizin Kardiologie Abstract: OBJECTIVES: – Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. – – METHODS: – The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. – – RESULTS: – Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. – – CONCLUSIONS: – We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion. – – © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Resumo:
A medical cyclotron accelerating H- ions to 18 MeV is in operation at the Bern University Hospital (Inselspital). It is the commercial IBA 18/18 cyclotron equipped with a specifically conceived 6 m long external beam line ending in a separate bunker. This feature is unique for a hospital-based facility and makes it possible to conduct routine radioisotope production for PET diagnostics in parallel with multidisciplinary research activities, among which are novel particle detectors, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. Several of these activities, such as radiobiology experiments for example, require low current beams down to the pA range, while medical cyclotrons are designed for high current operation above 10 μA. In this paper, we present the first results on the low current performance of a PET medical cyclotron obtained by ion source, radio-frequency and main coil tuning. With this method, stable beam currents down to (1.5+/- 0.5 ) pA were obtained and measured with a high-sensitivity Faraday cup located at the end of the beam transport line.